A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint

Pressure-sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique: the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of turbomachinery 2016-08, Vol.138 (8)
Hauptverfasser: Natsui, Greg, Little, Zachary, Kapat, Jayanta S, Dees, Jason E, Laskowski, Gregory
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 8
container_start_page
container_title Journal of turbomachinery
container_volume 138
creator Natsui, Greg
Little, Zachary
Kapat, Jayanta S
Dees, Jason E
Laskowski, Gregory
description Pressure-sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique: the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem being studied. This paper will assess the experimental aspect of this PSP measurement specifically for film cooling applications. Experiments are conducted in an effort to quantifiably bound expected errors associated with temperature nonuniformities in testing and photodegradation effects. Results show that if careful experimental procedures are put in place, both of these effects can be maintained to have less than 0.022 impact on effectiveness. Through accurate semi in situ calibration down to 4% atmospheric pressure, the near-hole distribution of effectiveness is measured with high accuracy. PSP calibrations are performed for multiple coupons, over multiple days. In addition, to reach a partial pressure of zero the calibration vessel was purged of all air by flowing CO2. The primary contribution of this paper lies in the uncertainty analysis performed on the PSP measurement technique. A thorough uncertainty analysis is conducted and described, in order to completely understand the presented measurements and any shortcomings of the PSP technique. This quantification results in larger, albeit more realistic, values of uncertainty and helps provide a better understanding of film cooling effectiveness measurements taken using the PSP technique. The presented uncertainty analysis takes into account all random error sources associated with sampling and calibration, from intensities to effectiveness. Adiabatic film cooling effectiveness measurements are obtained for a single row of film cooling holes inclined at 20 deg, with CO2 used as coolant. Data are obtained for six blowing ratios. Maps of uncertainty corresponding to each effectiveness profile are available for each test case. These maps show that the uncertainty varies spatially over the test surface and high effectiveness corresponds to low uncertainty. The noise floors can be as high as 0.04 at effectiveness levels of 0. Day-to-day repeatability is presented for each blowing ratio and shows that laterally averaged effectiveness data are repeatable within 0.02 effectiveness.
doi_str_mv 10.1115/1.4032674
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1825542266</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1825542266</sourcerecordid><originalsourceid>FETCH-LOGICAL-a282t-6717a30ccc8d6aafc326ca69f48612a414235c52a4209edac3147fe0762892ef3</originalsourceid><addsrcrecordid>eNotkE1LAzEQhoMoWKsHz15y1MPWfG02eyy1VaFiQQveQkwnkrIfNbMr9N-7pT3Ny8zDC_MQcsvZhHOeP_KJYlLoQp2REc-FyUzJ2DkZMWPKLGfq65JcIW4Z41LmakRwSp-gc7GCDV03HtKQm25Pp42r9hiRtoFON9F9uy56uohVTWdtW8Xmh85DAN_FP2gAkb6Bwz5BDU2HdI0HYJWGw7DLPqDBeCDp6tB-TS6CqxBuTnNM1ov55-wlW74_v86my8wJI7pMF7xwknnvzUY7F_zwl3e6DMpoLpziSsjc50MSrISN85KrIgArtDClgCDH5P7Yu0vtbw_Y2Tqih6pyDbQ9Wm5EnishtB7QhyPqU4uYINhdirVLe8uZPYi13J7EDuzdkXVYg922fRpcoZWF0UbLf_eKdJA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1825542266</pqid></control><display><type>article</type><title>A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint</title><source>ASME Transactions Journals (Current)</source><source>Alma/SFX Local Collection</source><creator>Natsui, Greg ; Little, Zachary ; Kapat, Jayanta S ; Dees, Jason E ; Laskowski, Gregory</creator><creatorcontrib>Natsui, Greg ; Little, Zachary ; Kapat, Jayanta S ; Dees, Jason E ; Laskowski, Gregory</creatorcontrib><description>Pressure-sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique: the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem being studied. This paper will assess the experimental aspect of this PSP measurement specifically for film cooling applications. Experiments are conducted in an effort to quantifiably bound expected errors associated with temperature nonuniformities in testing and photodegradation effects. Results show that if careful experimental procedures are put in place, both of these effects can be maintained to have less than 0.022 impact on effectiveness. Through accurate semi in situ calibration down to 4% atmospheric pressure, the near-hole distribution of effectiveness is measured with high accuracy. PSP calibrations are performed for multiple coupons, over multiple days. In addition, to reach a partial pressure of zero the calibration vessel was purged of all air by flowing CO2. The primary contribution of this paper lies in the uncertainty analysis performed on the PSP measurement technique. A thorough uncertainty analysis is conducted and described, in order to completely understand the presented measurements and any shortcomings of the PSP technique. This quantification results in larger, albeit more realistic, values of uncertainty and helps provide a better understanding of film cooling effectiveness measurements taken using the PSP technique. The presented uncertainty analysis takes into account all random error sources associated with sampling and calibration, from intensities to effectiveness. Adiabatic film cooling effectiveness measurements are obtained for a single row of film cooling holes inclined at 20 deg, with CO2 used as coolant. Data are obtained for six blowing ratios. Maps of uncertainty corresponding to each effectiveness profile are available for each test case. These maps show that the uncertainty varies spatially over the test surface and high effectiveness corresponds to low uncertainty. The noise floors can be as high as 0.04 at effectiveness levels of 0. Day-to-day repeatability is presented for each blowing ratio and shows that laterally averaged effectiveness data are repeatable within 0.02 effectiveness.</description><identifier>ISSN: 0889-504X</identifier><identifier>EISSN: 1528-8900</identifier><identifier>DOI: 10.1115/1.4032674</identifier><language>eng</language><publisher>ASME</publisher><subject>Adiabatic flow ; Blowing ; Calibration ; Carbon dioxide ; Film cooling ; Pressure-sensitive paints ; Uncertainty</subject><ispartof>Journal of turbomachinery, 2016-08, Vol.138 (8)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a282t-6717a30ccc8d6aafc326ca69f48612a414235c52a4209edac3147fe0762892ef3</citedby><cites>FETCH-LOGICAL-a282t-6717a30ccc8d6aafc326ca69f48612a414235c52a4209edac3147fe0762892ef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,38520</link.rule.ids></links><search><creatorcontrib>Natsui, Greg</creatorcontrib><creatorcontrib>Little, Zachary</creatorcontrib><creatorcontrib>Kapat, Jayanta S</creatorcontrib><creatorcontrib>Dees, Jason E</creatorcontrib><creatorcontrib>Laskowski, Gregory</creatorcontrib><title>A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint</title><title>Journal of turbomachinery</title><addtitle>J. Turbomach</addtitle><description>Pressure-sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique: the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem being studied. This paper will assess the experimental aspect of this PSP measurement specifically for film cooling applications. Experiments are conducted in an effort to quantifiably bound expected errors associated with temperature nonuniformities in testing and photodegradation effects. Results show that if careful experimental procedures are put in place, both of these effects can be maintained to have less than 0.022 impact on effectiveness. Through accurate semi in situ calibration down to 4% atmospheric pressure, the near-hole distribution of effectiveness is measured with high accuracy. PSP calibrations are performed for multiple coupons, over multiple days. In addition, to reach a partial pressure of zero the calibration vessel was purged of all air by flowing CO2. The primary contribution of this paper lies in the uncertainty analysis performed on the PSP measurement technique. A thorough uncertainty analysis is conducted and described, in order to completely understand the presented measurements and any shortcomings of the PSP technique. This quantification results in larger, albeit more realistic, values of uncertainty and helps provide a better understanding of film cooling effectiveness measurements taken using the PSP technique. The presented uncertainty analysis takes into account all random error sources associated with sampling and calibration, from intensities to effectiveness. Adiabatic film cooling effectiveness measurements are obtained for a single row of film cooling holes inclined at 20 deg, with CO2 used as coolant. Data are obtained for six blowing ratios. Maps of uncertainty corresponding to each effectiveness profile are available for each test case. These maps show that the uncertainty varies spatially over the test surface and high effectiveness corresponds to low uncertainty. The noise floors can be as high as 0.04 at effectiveness levels of 0. Day-to-day repeatability is presented for each blowing ratio and shows that laterally averaged effectiveness data are repeatable within 0.02 effectiveness.</description><subject>Adiabatic flow</subject><subject>Blowing</subject><subject>Calibration</subject><subject>Carbon dioxide</subject><subject>Film cooling</subject><subject>Pressure-sensitive paints</subject><subject>Uncertainty</subject><issn>0889-504X</issn><issn>1528-8900</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNotkE1LAzEQhoMoWKsHz15y1MPWfG02eyy1VaFiQQveQkwnkrIfNbMr9N-7pT3Ny8zDC_MQcsvZhHOeP_KJYlLoQp2REc-FyUzJ2DkZMWPKLGfq65JcIW4Z41LmakRwSp-gc7GCDV03HtKQm25Pp42r9hiRtoFON9F9uy56uohVTWdtW8Xmh85DAN_FP2gAkb6Bwz5BDU2HdI0HYJWGw7DLPqDBeCDp6tB-TS6CqxBuTnNM1ov55-wlW74_v86my8wJI7pMF7xwknnvzUY7F_zwl3e6DMpoLpziSsjc50MSrISN85KrIgArtDClgCDH5P7Yu0vtbw_Y2Tqih6pyDbQ9Wm5EnishtB7QhyPqU4uYINhdirVLe8uZPYi13J7EDuzdkXVYg922fRpcoZWF0UbLf_eKdJA</recordid><startdate>20160801</startdate><enddate>20160801</enddate><creator>Natsui, Greg</creator><creator>Little, Zachary</creator><creator>Kapat, Jayanta S</creator><creator>Dees, Jason E</creator><creator>Laskowski, Gregory</creator><general>ASME</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20160801</creationdate><title>A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint</title><author>Natsui, Greg ; Little, Zachary ; Kapat, Jayanta S ; Dees, Jason E ; Laskowski, Gregory</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a282t-6717a30ccc8d6aafc326ca69f48612a414235c52a4209edac3147fe0762892ef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adiabatic flow</topic><topic>Blowing</topic><topic>Calibration</topic><topic>Carbon dioxide</topic><topic>Film cooling</topic><topic>Pressure-sensitive paints</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Natsui, Greg</creatorcontrib><creatorcontrib>Little, Zachary</creatorcontrib><creatorcontrib>Kapat, Jayanta S</creatorcontrib><creatorcontrib>Dees, Jason E</creatorcontrib><creatorcontrib>Laskowski, Gregory</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of turbomachinery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Natsui, Greg</au><au>Little, Zachary</au><au>Kapat, Jayanta S</au><au>Dees, Jason E</au><au>Laskowski, Gregory</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint</atitle><jtitle>Journal of turbomachinery</jtitle><stitle>J. Turbomach</stitle><date>2016-08-01</date><risdate>2016</risdate><volume>138</volume><issue>8</issue><issn>0889-504X</issn><eissn>1528-8900</eissn><abstract>Pressure-sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique: the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem being studied. This paper will assess the experimental aspect of this PSP measurement specifically for film cooling applications. Experiments are conducted in an effort to quantifiably bound expected errors associated with temperature nonuniformities in testing and photodegradation effects. Results show that if careful experimental procedures are put in place, both of these effects can be maintained to have less than 0.022 impact on effectiveness. Through accurate semi in situ calibration down to 4% atmospheric pressure, the near-hole distribution of effectiveness is measured with high accuracy. PSP calibrations are performed for multiple coupons, over multiple days. In addition, to reach a partial pressure of zero the calibration vessel was purged of all air by flowing CO2. The primary contribution of this paper lies in the uncertainty analysis performed on the PSP measurement technique. A thorough uncertainty analysis is conducted and described, in order to completely understand the presented measurements and any shortcomings of the PSP technique. This quantification results in larger, albeit more realistic, values of uncertainty and helps provide a better understanding of film cooling effectiveness measurements taken using the PSP technique. The presented uncertainty analysis takes into account all random error sources associated with sampling and calibration, from intensities to effectiveness. Adiabatic film cooling effectiveness measurements are obtained for a single row of film cooling holes inclined at 20 deg, with CO2 used as coolant. Data are obtained for six blowing ratios. Maps of uncertainty corresponding to each effectiveness profile are available for each test case. These maps show that the uncertainty varies spatially over the test surface and high effectiveness corresponds to low uncertainty. The noise floors can be as high as 0.04 at effectiveness levels of 0. Day-to-day repeatability is presented for each blowing ratio and shows that laterally averaged effectiveness data are repeatable within 0.02 effectiveness.</abstract><pub>ASME</pub><doi>10.1115/1.4032674</doi></addata></record>
fulltext fulltext
identifier ISSN: 0889-504X
ispartof Journal of turbomachinery, 2016-08, Vol.138 (8)
issn 0889-504X
1528-8900
language eng
recordid cdi_proquest_miscellaneous_1825542266
source ASME Transactions Journals (Current); Alma/SFX Local Collection
subjects Adiabatic flow
Blowing
Calibration
Carbon dioxide
Film cooling
Pressure-sensitive paints
Uncertainty
title A Detailed Uncertainty Analysis of Adiabatic Film Cooling Effectiveness Measurements Using Pressure-Sensitive Paint
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T05%3A06%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Detailed%20Uncertainty%20Analysis%20of%20Adiabatic%20Film%20Cooling%20Effectiveness%20Measurements%20Using%20Pressure-Sensitive%20Paint&rft.jtitle=Journal%20of%20turbomachinery&rft.au=Natsui,%20Greg&rft.date=2016-08-01&rft.volume=138&rft.issue=8&rft.issn=0889-504X&rft.eissn=1528-8900&rft_id=info:doi/10.1115/1.4032674&rft_dat=%3Cproquest_cross%3E1825542266%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1825542266&rft_id=info:pmid/&rfr_iscdi=true