Stagnation temperature measurement using thin-film platinum resistance sensors

The measurement of stagnation temperature in high-speed flows is an important aspect of gas turbine engine testing. The ongoing requirement to improve the accuracy of such measurements has led to the development of probe systems that use a thin-film platinum resistance thermometer (PRT) as the sensi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2014-01, Vol.25 (1), p.15101-16
Hauptverfasser: Bonham, C, Thorpe, S J, Erlund, M N, Stevenson, R D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 16
container_issue 1
container_start_page 15101
container_title Measurement science & technology
container_volume 25
creator Bonham, C
Thorpe, S J
Erlund, M N
Stevenson, R D
description The measurement of stagnation temperature in high-speed flows is an important aspect of gas turbine engine testing. The ongoing requirement to improve the accuracy of such measurements has led to the development of probe systems that use a thin-film platinum resistance thermometer (PRT) as the sensing element. For certain aspects of engine testing this type of sensing device potentially offers superior measurement performance to the thermocouple, the temperature sensor of choice in most gas turbine applications. This paper considers the measurement performance of prototype PRT-based stagnation temperature probes, up to high-subsonic flow conditions, using passively aspirated probe heads. The relatively poor temperature recovery performance of a simply constructed probe has led to the development of a new design that is intended to reduce the impact of thermal conduction within the probe assembly. The performance of this so-called dual-skin probe has been measured through a series of tests at a range of Mach numbers, incidence angles and Reynolds numbers. The data reveal that a high probe recovery factor has been achieved with this device, and that the application of this design to engine tests would yield the measurement performance benefits of the PRT whilst requiring small levels of temperature recovery compensation.
doi_str_mv 10.1088/0957-0233/25/1/015101
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1825525296</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1825525296</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-e94480dc527a74f7a293597602349ff1732043f46048a92825403a22dfe422323</originalsourceid><addsrcrecordid>eNp9kLtOxDAQRS0EEsvjE5DSQRMyfsVxiVa8pBUUQG1ZWXvxKnaC7RT8PV4tQhSIappz78wchC4wXGPougYkFzUQShvCG9wA5hjwAVpg2uK65YAP0eKHOUYnKW0BQICUC_T0kvUm6OzGUGXjJxN1nqOpvNGpTG9CrubkwqbK7y7U1g2-mobCh9lX0SSXsg69qZIJaYzpDB1ZPSRz_j1P0dvd7evyoV493z8ub1Z1z0Dk2kjGOlj3nAgtmBWaSMqlaMuBTFqLBSXAqGUtsE5L0hHOgGpC1tYwQiihp-hq3zvF8WM2KSvvUm-GQQczzknhEuGEE9kWlO_RPo4pRWPVFJ3X8VNhUDt_audG7dwowhVWe38ld7nPuXFS23GOoTykfFn1i1LT2hYS_0H-3_4FkCB-Nw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1825525296</pqid></control><display><type>article</type><title>Stagnation temperature measurement using thin-film platinum resistance sensors</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Bonham, C ; Thorpe, S J ; Erlund, M N ; Stevenson, R D</creator><creatorcontrib>Bonham, C ; Thorpe, S J ; Erlund, M N ; Stevenson, R D</creatorcontrib><description>The measurement of stagnation temperature in high-speed flows is an important aspect of gas turbine engine testing. The ongoing requirement to improve the accuracy of such measurements has led to the development of probe systems that use a thin-film platinum resistance thermometer (PRT) as the sensing element. For certain aspects of engine testing this type of sensing device potentially offers superior measurement performance to the thermocouple, the temperature sensor of choice in most gas turbine applications. This paper considers the measurement performance of prototype PRT-based stagnation temperature probes, up to high-subsonic flow conditions, using passively aspirated probe heads. The relatively poor temperature recovery performance of a simply constructed probe has led to the development of a new design that is intended to reduce the impact of thermal conduction within the probe assembly. The performance of this so-called dual-skin probe has been measured through a series of tests at a range of Mach numbers, incidence angles and Reynolds numbers. The data reveal that a high probe recovery factor has been achieved with this device, and that the application of this design to engine tests would yield the measurement performance benefits of the PRT whilst requiring small levels of temperature recovery compensation.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/0957-0233/25/1/015101</identifier><identifier>CODEN: MSTCEP</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>Data recovery ; Design engineering ; Engine tests ; Platinum ; recovery factor ; resistance thermometry ; Sensing devices ; Stagnation temperature ; Thermocouples ; Thin films</subject><ispartof>Measurement science &amp; technology, 2014-01, Vol.25 (1), p.15101-16</ispartof><rights>2014 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-e94480dc527a74f7a293597602349ff1732043f46048a92825403a22dfe422323</citedby><cites>FETCH-LOGICAL-c407t-e94480dc527a74f7a293597602349ff1732043f46048a92825403a22dfe422323</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0957-0233/25/1/015101/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27923,27924,53845,53892</link.rule.ids></links><search><creatorcontrib>Bonham, C</creatorcontrib><creatorcontrib>Thorpe, S J</creatorcontrib><creatorcontrib>Erlund, M N</creatorcontrib><creatorcontrib>Stevenson, R D</creatorcontrib><title>Stagnation temperature measurement using thin-film platinum resistance sensors</title><title>Measurement science &amp; technology</title><addtitle>MST</addtitle><addtitle>Meas. Sci. Technol</addtitle><description>The measurement of stagnation temperature in high-speed flows is an important aspect of gas turbine engine testing. The ongoing requirement to improve the accuracy of such measurements has led to the development of probe systems that use a thin-film platinum resistance thermometer (PRT) as the sensing element. For certain aspects of engine testing this type of sensing device potentially offers superior measurement performance to the thermocouple, the temperature sensor of choice in most gas turbine applications. This paper considers the measurement performance of prototype PRT-based stagnation temperature probes, up to high-subsonic flow conditions, using passively aspirated probe heads. The relatively poor temperature recovery performance of a simply constructed probe has led to the development of a new design that is intended to reduce the impact of thermal conduction within the probe assembly. The performance of this so-called dual-skin probe has been measured through a series of tests at a range of Mach numbers, incidence angles and Reynolds numbers. The data reveal that a high probe recovery factor has been achieved with this device, and that the application of this design to engine tests would yield the measurement performance benefits of the PRT whilst requiring small levels of temperature recovery compensation.</description><subject>Data recovery</subject><subject>Design engineering</subject><subject>Engine tests</subject><subject>Platinum</subject><subject>recovery factor</subject><subject>resistance thermometry</subject><subject>Sensing devices</subject><subject>Stagnation temperature</subject><subject>Thermocouples</subject><subject>Thin films</subject><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp9kLtOxDAQRS0EEsvjE5DSQRMyfsVxiVa8pBUUQG1ZWXvxKnaC7RT8PV4tQhSIappz78wchC4wXGPougYkFzUQShvCG9wA5hjwAVpg2uK65YAP0eKHOUYnKW0BQICUC_T0kvUm6OzGUGXjJxN1nqOpvNGpTG9CrubkwqbK7y7U1g2-mobCh9lX0SSXsg69qZIJaYzpDB1ZPSRz_j1P0dvd7evyoV493z8ub1Z1z0Dk2kjGOlj3nAgtmBWaSMqlaMuBTFqLBSXAqGUtsE5L0hHOgGpC1tYwQiihp-hq3zvF8WM2KSvvUm-GQQczzknhEuGEE9kWlO_RPo4pRWPVFJ3X8VNhUDt_audG7dwowhVWe38ld7nPuXFS23GOoTykfFn1i1LT2hYS_0H-3_4FkCB-Nw</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Bonham, C</creator><creator>Thorpe, S J</creator><creator>Erlund, M N</creator><creator>Stevenson, R D</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20140101</creationdate><title>Stagnation temperature measurement using thin-film platinum resistance sensors</title><author>Bonham, C ; Thorpe, S J ; Erlund, M N ; Stevenson, R D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-e94480dc527a74f7a293597602349ff1732043f46048a92825403a22dfe422323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Data recovery</topic><topic>Design engineering</topic><topic>Engine tests</topic><topic>Platinum</topic><topic>recovery factor</topic><topic>resistance thermometry</topic><topic>Sensing devices</topic><topic>Stagnation temperature</topic><topic>Thermocouples</topic><topic>Thin films</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bonham, C</creatorcontrib><creatorcontrib>Thorpe, S J</creatorcontrib><creatorcontrib>Erlund, M N</creatorcontrib><creatorcontrib>Stevenson, R D</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Measurement science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bonham, C</au><au>Thorpe, S J</au><au>Erlund, M N</au><au>Stevenson, R D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stagnation temperature measurement using thin-film platinum resistance sensors</atitle><jtitle>Measurement science &amp; technology</jtitle><stitle>MST</stitle><addtitle>Meas. Sci. Technol</addtitle><date>2014-01-01</date><risdate>2014</risdate><volume>25</volume><issue>1</issue><spage>15101</spage><epage>16</epage><pages>15101-16</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><coden>MSTCEP</coden><abstract>The measurement of stagnation temperature in high-speed flows is an important aspect of gas turbine engine testing. The ongoing requirement to improve the accuracy of such measurements has led to the development of probe systems that use a thin-film platinum resistance thermometer (PRT) as the sensing element. For certain aspects of engine testing this type of sensing device potentially offers superior measurement performance to the thermocouple, the temperature sensor of choice in most gas turbine applications. This paper considers the measurement performance of prototype PRT-based stagnation temperature probes, up to high-subsonic flow conditions, using passively aspirated probe heads. The relatively poor temperature recovery performance of a simply constructed probe has led to the development of a new design that is intended to reduce the impact of thermal conduction within the probe assembly. The performance of this so-called dual-skin probe has been measured through a series of tests at a range of Mach numbers, incidence angles and Reynolds numbers. The data reveal that a high probe recovery factor has been achieved with this device, and that the application of this design to engine tests would yield the measurement performance benefits of the PRT whilst requiring small levels of temperature recovery compensation.</abstract><pub>IOP Publishing</pub><doi>10.1088/0957-0233/25/1/015101</doi><tpages>16</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0957-0233
ispartof Measurement science & technology, 2014-01, Vol.25 (1), p.15101-16
issn 0957-0233
1361-6501
language eng
recordid cdi_proquest_miscellaneous_1825525296
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Data recovery
Design engineering
Engine tests
Platinum
recovery factor
resistance thermometry
Sensing devices
Stagnation temperature
Thermocouples
Thin films
title Stagnation temperature measurement using thin-film platinum resistance sensors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T15%3A54%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stagnation%20temperature%20measurement%20using%20thin-film%20platinum%20resistance%20sensors&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Bonham,%20C&rft.date=2014-01-01&rft.volume=25&rft.issue=1&rft.spage=15101&rft.epage=16&rft.pages=15101-16&rft.issn=0957-0233&rft.eissn=1361-6501&rft.coden=MSTCEP&rft_id=info:doi/10.1088/0957-0233/25/1/015101&rft_dat=%3Cproquest_cross%3E1825525296%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1825525296&rft_id=info:pmid/&rfr_iscdi=true