Cardiac implantable electronic devices in tracheotomized muscular dystrophy patients: Safety and risks

Abstract Background/objectives Muscular dystrophies are genetic muscle disorders, in which heart involvement and chronic respiratory impairment affect survival. Cardiac conduction disturbances require implantable cardiac pacemaker. Implantable defibrillators may also be necessary to prevent cardiac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of cardiology 2016-11, Vol.222, p.975-977
Hauptverfasser: Fayssoil, Abdallah, MD PhD, Lazarus, Arnaud, MD, Wahbi, Karim, MD PhD, Ogna, Adam, MD, Nardi, Olivier, MD PhD, Lofaso, Frederic, MD PhD, Clair, Bernard, MD, Orlikowski, David, MD PhD, Annane, Djillali, MD PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background/objectives Muscular dystrophies are genetic muscle disorders, in which heart involvement and chronic respiratory impairment affect survival. Cardiac conduction disturbances require implantable cardiac pacemaker. Implantable defibrillators may also be necessary to prevent cardiac sudden death. The safety and risk of cardiac electronic devices' implantation are not known in patients with muscular dystrophy. We aimed to assess the risks related to cardiac implantable electronic devices (CIED) in muscular dystrophy patients ventilated by tracheostomy. Methods We reviewed all medical charts of neuromuscular patients and identified all CIED implantations of pacemakers (PM) or defibrillators (ICD) in patients ventilated using tracheostomy. Results Twelve device implantations were included, performed in 9 patients (5 DMD, 1 Becker muscular dystrophy and 3 DM1). Mean age was 39.9 years ± 13.0. All patients were wheel-chair bound and tracheotomized. Six pacemakers (PM) and 6 cardiac resynchronization (CRT) devices, including 2 defibrillators (CRT-D) were implanted. Following device implantation, two patients had a pneumothorax and one died from severe heart failure after an unsuccessful CRT implant attempt. Follow-up lasted up to 8 years (mean 2.6 ± 2.9 years), during which one patient presented a PM pocket infection, requiring PM explantation and epicardial reimplantation. Conclusion We found a high prevalence of early complications (16.6% pneumothorax) after CIED implantation and an acceptable long-term infectious risk (8.3%). These results highlight the feasibility of CIED implantation in tracheotomized patients with muscular dystrophies and the need for a particular caution in the management of these patients during invasive procedures. ClinicalTrials.gov (identifier: NCT02501083 ).
ISSN:0167-5273
1874-1754
DOI:10.1016/j.ijcard.2016.08.040