The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines
A fire occurred in the Tauern Tunnel, Austria on 29 May 1999 and caused severe casualties and damage. This paper examines the damage in the tunnel and the remedial work carried out — with a particular emphasis on the additional safety equipment required in the tunnel. The Austrian guidelines for tun...
Gespeichert in:
Veröffentlicht in: | Tunnelling and underground space technology 2001-07, Vol.16 (3), p.217-223 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 223 |
---|---|
container_issue | 3 |
container_start_page | 217 |
container_title | Tunnelling and underground space technology |
container_volume | 16 |
creator | Leitner, A |
description | A fire occurred in the Tauern Tunnel, Austria on 29 May 1999 and caused severe casualties and damage. This paper examines the damage in the tunnel and the remedial work carried out — with a particular emphasis on the additional safety equipment required in the tunnel. The Austrian guidelines for tunnel construction have been subsequently revised to improve the fire safety in tunnels. |
doi_str_mv | 10.1016/S0886-7798(01)00042-6 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_18233522</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0886779801000426</els_id><sourcerecordid>18233522</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-2ef4b6bccaf1cb7fcb65062476a675238b273ade714abe7f7d7fcf25477b8f783</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKs_QchF0cNqks0mqRcpxS8oeLCeQzY70cg2W5Nd0X9v2ooePQ0Mz_sO8yB0TMkFJVRcPhGlRCHlRJ0Rek4I4awQO2hElVQFLwXfRaNfZB8dpPSWoYqxyQiZxStg5yNga3qT-tit8sIH3OexMAPEgBdDCNBeYfhcQfQQLGATGmy7YNsh-S4k7Lq4SUyHXOFNwC-Db6D1AdIh2nOmTXD0M8fo-fZmMbsv5o93D7PpvLC85H3BwPFa1NYaR20tna1FRQTjUhghK1aqmsnSNCApNzVIJ5vMOFZxKWvlpCrH6HTbu4rd-wCp10ufLLStCdANSVPFyjI_ncFqC9rYpRTB6VX0SxO_NCV6LVRvhOq1LU2o3gjVIudOfg6YZE3rognWp7-wYESJimfuestB_vbDQ9TJbqw1WbPtddP5fy59A_F7i-U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>18233522</pqid></control><display><type>article</type><title>The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Leitner, A</creator><creatorcontrib>Leitner, A</creatorcontrib><description>A fire occurred in the Tauern Tunnel, Austria on 29 May 1999 and caused severe casualties and damage. This paper examines the damage in the tunnel and the remedial work carried out — with a particular emphasis on the additional safety equipment required in the tunnel. The Austrian guidelines for tunnel construction have been subsequently revised to improve the fire safety in tunnels.</description><identifier>ISSN: 0886-7798</identifier><identifier>EISSN: 1878-4364</identifier><identifier>DOI: 10.1016/S0886-7798(01)00042-6</identifier><identifier>CODEN: TUSTEQ</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Austrian guidelines ; Buildings. Public works ; Exact sciences and technology ; Fire damage ; Fire safety ; search and rescue ; Tauern Tunnel ; Tunnels, galleries</subject><ispartof>Tunnelling and underground space technology, 2001-07, Vol.16 (3), p.217-223</ispartof><rights>2001 Elsevier Science Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-2ef4b6bccaf1cb7fcb65062476a675238b273ade714abe7f7d7fcf25477b8f783</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0886779801000426$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=16208654$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Leitner, A</creatorcontrib><title>The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines</title><title>Tunnelling and underground space technology</title><description>A fire occurred in the Tauern Tunnel, Austria on 29 May 1999 and caused severe casualties and damage. This paper examines the damage in the tunnel and the remedial work carried out — with a particular emphasis on the additional safety equipment required in the tunnel. The Austrian guidelines for tunnel construction have been subsequently revised to improve the fire safety in tunnels.</description><subject>Applied sciences</subject><subject>Austrian guidelines</subject><subject>Buildings. Public works</subject><subject>Exact sciences and technology</subject><subject>Fire damage</subject><subject>Fire safety</subject><subject>search and rescue</subject><subject>Tauern Tunnel</subject><subject>Tunnels, galleries</subject><issn>0886-7798</issn><issn>1878-4364</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKs_QchF0cNqks0mqRcpxS8oeLCeQzY70cg2W5Nd0X9v2ooePQ0Mz_sO8yB0TMkFJVRcPhGlRCHlRJ0Rek4I4awQO2hElVQFLwXfRaNfZB8dpPSWoYqxyQiZxStg5yNga3qT-tit8sIH3OexMAPEgBdDCNBeYfhcQfQQLGATGmy7YNsh-S4k7Lq4SUyHXOFNwC-Db6D1AdIh2nOmTXD0M8fo-fZmMbsv5o93D7PpvLC85H3BwPFa1NYaR20tna1FRQTjUhghK1aqmsnSNCApNzVIJ5vMOFZxKWvlpCrH6HTbu4rd-wCp10ufLLStCdANSVPFyjI_ncFqC9rYpRTB6VX0SxO_NCV6LVRvhOq1LU2o3gjVIudOfg6YZE3rognWp7-wYESJimfuestB_vbDQ9TJbqw1WbPtddP5fy59A_F7i-U</recordid><startdate>20010701</startdate><enddate>20010701</enddate><creator>Leitner, A</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>20010701</creationdate><title>The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines</title><author>Leitner, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-2ef4b6bccaf1cb7fcb65062476a675238b273ade714abe7f7d7fcf25477b8f783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Applied sciences</topic><topic>Austrian guidelines</topic><topic>Buildings. Public works</topic><topic>Exact sciences and technology</topic><topic>Fire damage</topic><topic>Fire safety</topic><topic>search and rescue</topic><topic>Tauern Tunnel</topic><topic>Tunnels, galleries</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leitner, A</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Tunnelling and underground space technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leitner, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines</atitle><jtitle>Tunnelling and underground space technology</jtitle><date>2001-07-01</date><risdate>2001</risdate><volume>16</volume><issue>3</issue><spage>217</spage><epage>223</epage><pages>217-223</pages><issn>0886-7798</issn><eissn>1878-4364</eissn><coden>TUSTEQ</coden><abstract>A fire occurred in the Tauern Tunnel, Austria on 29 May 1999 and caused severe casualties and damage. This paper examines the damage in the tunnel and the remedial work carried out — with a particular emphasis on the additional safety equipment required in the tunnel. The Austrian guidelines for tunnel construction have been subsequently revised to improve the fire safety in tunnels.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/S0886-7798(01)00042-6</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0886-7798 |
ispartof | Tunnelling and underground space technology, 2001-07, Vol.16 (3), p.217-223 |
issn | 0886-7798 1878-4364 |
language | eng |
recordid | cdi_proquest_miscellaneous_18233522 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Applied sciences Austrian guidelines Buildings. Public works Exact sciences and technology Fire damage Fire safety search and rescue Tauern Tunnel Tunnels, galleries |
title | The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T18%3A13%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20fire%20catastrophe%20in%20the%20Tauern%20Tunnel:%20experience%20and%20conclusions%20for%20the%20Austrian%20guidelines&rft.jtitle=Tunnelling%20and%20underground%20space%20technology&rft.au=Leitner,%20A&rft.date=2001-07-01&rft.volume=16&rft.issue=3&rft.spage=217&rft.epage=223&rft.pages=217-223&rft.issn=0886-7798&rft.eissn=1878-4364&rft.coden=TUSTEQ&rft_id=info:doi/10.1016/S0886-7798(01)00042-6&rft_dat=%3Cproquest_cross%3E18233522%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=18233522&rft_id=info:pmid/&rft_els_id=S0886779801000426&rfr_iscdi=true |