Thermodynamic analysis of ventilated façades under different wind conditions in summer period

•CFD simulation of an opaque ventilated façade.•Different wind scenario were investigated.•The energy saving obtainable in comparison with unventilated façade were calculated.•The ventilated façade reduces the peak load and shifts the thermal wave. The main benefit attributed to opaque ventilated fa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 2016-06, Vol.122, p.131-139
Hauptverfasser: Gagliano, A., Nocera, F., Aneli, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 139
container_issue
container_start_page 131
container_title Energy and buildings
container_volume 122
creator Gagliano, A.
Nocera, F.
Aneli, S.
description •CFD simulation of an opaque ventilated façade.•Different wind scenario were investigated.•The energy saving obtainable in comparison with unventilated façade were calculated.•The ventilated façade reduces the peak load and shifts the thermal wave. The main benefit attributed to opaque ventilated facades (OVF) is the reduction of cooling load for the building Heating Ventilation and Cooling (HVAC) achieved through ventilation led by natural convection in the ventilated chamber and the protection from solar radiation given by the outer layer of the façade. This research investigates the thermal behavior of an opaque naturally ventilated façade through Computation Fluid Dynamics (CFD) simulations during summer days. The CFD simulations have been performed in order to analyze the behavior of DSF components under different wind conditions in the summer period, utilizing the weather data of Catania city (Italy). For the different investigated scenarios, the authors have calculated the temperature and air velocity profiles inside the air gap of the façade, highlighting the different effects of buoyancy and wind forces. The results show that the wind forces in conjunction with the buoyancy forces affect significantly the performance of OVF components. Further, the reduction of the heat flux during the summer period has been evaluated by comparing the thermodynamic performance of a naturally ventilated and an unventilated façade with the same geometry and thermo-physical characteristics. The behavior of the naturally ventilated façade is an improvement in terms of passive cooling of the building compared to the non-ventilated façade since it allows the peak load to be shifted whilst offering energy savings in the range of 47% to 51% depending on climate.
doi_str_mv 10.1016/j.enbuild.2016.04.035
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1816085550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378778816302882</els_id><sourcerecordid>1808678485</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-9f53cc5652eda1f6a3b68c780094c10d146dfb98f53c2dd4872b9b773eb416153</originalsourceid><addsrcrecordid>eNqNkMtKxDAUhrtQcLw8gpClm9akbS5diQzeYMDNuDWkyQlmaJMxaUfmiXwQX8yWmb2uDofz_T-cL8uuCS4IJux2U4BvR9eZopzWAtcFruhJtsAVFznnQpxl5yltMMaMcrLI3tcfEPtg9l71TiPlVbdPLqFg0Q784Do1gEFW_XwrAwmN3kBExlkLcTqjL-cN0sEbN7jgE3IepbHvJ2YL0QVzmZ1a1SW4Os6L7O3xYb18zlevTy_L-1WuK06HvLG00poyWoJRxDJVtUxoLjBuak2wITUztm3EjJXG1IKXbdNyXkFbE0ZodZHdHHq3MXyOkAbZu6Sh65SHMCZJBGFYUErxP1AsGBe1mFvpAdUxpBTBym10vYp7SbCcdcuNPOqWs26JaznpnnJ3hxxML-8cRJm0A6_BuAh6kCa4Pxp-ARsjj3A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1808678485</pqid></control><display><type>article</type><title>Thermodynamic analysis of ventilated façades under different wind conditions in summer period</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Gagliano, A. ; Nocera, F. ; Aneli, S.</creator><creatorcontrib>Gagliano, A. ; Nocera, F. ; Aneli, S.</creatorcontrib><description>•CFD simulation of an opaque ventilated façade.•Different wind scenario were investigated.•The energy saving obtainable in comparison with unventilated façade were calculated.•The ventilated façade reduces the peak load and shifts the thermal wave. The main benefit attributed to opaque ventilated facades (OVF) is the reduction of cooling load for the building Heating Ventilation and Cooling (HVAC) achieved through ventilation led by natural convection in the ventilated chamber and the protection from solar radiation given by the outer layer of the façade. This research investigates the thermal behavior of an opaque naturally ventilated façade through Computation Fluid Dynamics (CFD) simulations during summer days. The CFD simulations have been performed in order to analyze the behavior of DSF components under different wind conditions in the summer period, utilizing the weather data of Catania city (Italy). For the different investigated scenarios, the authors have calculated the temperature and air velocity profiles inside the air gap of the façade, highlighting the different effects of buoyancy and wind forces. The results show that the wind forces in conjunction with the buoyancy forces affect significantly the performance of OVF components. Further, the reduction of the heat flux during the summer period has been evaluated by comparing the thermodynamic performance of a naturally ventilated and an unventilated façade with the same geometry and thermo-physical characteristics. The behavior of the naturally ventilated façade is an improvement in terms of passive cooling of the building compared to the non-ventilated façade since it allows the peak load to be shifted whilst offering energy savings in the range of 47% to 51% depending on climate.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/j.enbuild.2016.04.035</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Buoyancy ; Computational fluid dynamics ; Computer simulation ; Cooling ; Cooling load ; Facades ; Fluid dynamic ; Mathematical models ; Natural ventilation ; Opaque ventilated facades ; Reduction ; Summer ; Wind scenario</subject><ispartof>Energy and buildings, 2016-06, Vol.122, p.131-139</ispartof><rights>2016 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-9f53cc5652eda1f6a3b68c780094c10d146dfb98f53c2dd4872b9b773eb416153</citedby><cites>FETCH-LOGICAL-c375t-9f53cc5652eda1f6a3b68c780094c10d146dfb98f53c2dd4872b9b773eb416153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.enbuild.2016.04.035$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Gagliano, A.</creatorcontrib><creatorcontrib>Nocera, F.</creatorcontrib><creatorcontrib>Aneli, S.</creatorcontrib><title>Thermodynamic analysis of ventilated façades under different wind conditions in summer period</title><title>Energy and buildings</title><description>•CFD simulation of an opaque ventilated façade.•Different wind scenario were investigated.•The energy saving obtainable in comparison with unventilated façade were calculated.•The ventilated façade reduces the peak load and shifts the thermal wave. The main benefit attributed to opaque ventilated facades (OVF) is the reduction of cooling load for the building Heating Ventilation and Cooling (HVAC) achieved through ventilation led by natural convection in the ventilated chamber and the protection from solar radiation given by the outer layer of the façade. This research investigates the thermal behavior of an opaque naturally ventilated façade through Computation Fluid Dynamics (CFD) simulations during summer days. The CFD simulations have been performed in order to analyze the behavior of DSF components under different wind conditions in the summer period, utilizing the weather data of Catania city (Italy). For the different investigated scenarios, the authors have calculated the temperature and air velocity profiles inside the air gap of the façade, highlighting the different effects of buoyancy and wind forces. The results show that the wind forces in conjunction with the buoyancy forces affect significantly the performance of OVF components. Further, the reduction of the heat flux during the summer period has been evaluated by comparing the thermodynamic performance of a naturally ventilated and an unventilated façade with the same geometry and thermo-physical characteristics. The behavior of the naturally ventilated façade is an improvement in terms of passive cooling of the building compared to the non-ventilated façade since it allows the peak load to be shifted whilst offering energy savings in the range of 47% to 51% depending on climate.</description><subject>Buoyancy</subject><subject>Computational fluid dynamics</subject><subject>Computer simulation</subject><subject>Cooling</subject><subject>Cooling load</subject><subject>Facades</subject><subject>Fluid dynamic</subject><subject>Mathematical models</subject><subject>Natural ventilation</subject><subject>Opaque ventilated facades</subject><subject>Reduction</subject><subject>Summer</subject><subject>Wind scenario</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqNkMtKxDAUhrtQcLw8gpClm9akbS5diQzeYMDNuDWkyQlmaJMxaUfmiXwQX8yWmb2uDofz_T-cL8uuCS4IJux2U4BvR9eZopzWAtcFruhJtsAVFznnQpxl5yltMMaMcrLI3tcfEPtg9l71TiPlVbdPLqFg0Q784Do1gEFW_XwrAwmN3kBExlkLcTqjL-cN0sEbN7jgE3IepbHvJ2YL0QVzmZ1a1SW4Os6L7O3xYb18zlevTy_L-1WuK06HvLG00poyWoJRxDJVtUxoLjBuak2wITUztm3EjJXG1IKXbdNyXkFbE0ZodZHdHHq3MXyOkAbZu6Sh65SHMCZJBGFYUErxP1AsGBe1mFvpAdUxpBTBym10vYp7SbCcdcuNPOqWs26JaznpnnJ3hxxML-8cRJm0A6_BuAh6kCa4Pxp-ARsjj3A</recordid><startdate>20160615</startdate><enddate>20160615</enddate><creator>Gagliano, A.</creator><creator>Nocera, F.</creator><creator>Aneli, S.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20160615</creationdate><title>Thermodynamic analysis of ventilated façades under different wind conditions in summer period</title><author>Gagliano, A. ; Nocera, F. ; Aneli, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-9f53cc5652eda1f6a3b68c780094c10d146dfb98f53c2dd4872b9b773eb416153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Buoyancy</topic><topic>Computational fluid dynamics</topic><topic>Computer simulation</topic><topic>Cooling</topic><topic>Cooling load</topic><topic>Facades</topic><topic>Fluid dynamic</topic><topic>Mathematical models</topic><topic>Natural ventilation</topic><topic>Opaque ventilated facades</topic><topic>Reduction</topic><topic>Summer</topic><topic>Wind scenario</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gagliano, A.</creatorcontrib><creatorcontrib>Nocera, F.</creatorcontrib><creatorcontrib>Aneli, S.</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gagliano, A.</au><au>Nocera, F.</au><au>Aneli, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Thermodynamic analysis of ventilated façades under different wind conditions in summer period</atitle><jtitle>Energy and buildings</jtitle><date>2016-06-15</date><risdate>2016</risdate><volume>122</volume><spage>131</spage><epage>139</epage><pages>131-139</pages><issn>0378-7788</issn><abstract>•CFD simulation of an opaque ventilated façade.•Different wind scenario were investigated.•The energy saving obtainable in comparison with unventilated façade were calculated.•The ventilated façade reduces the peak load and shifts the thermal wave. The main benefit attributed to opaque ventilated facades (OVF) is the reduction of cooling load for the building Heating Ventilation and Cooling (HVAC) achieved through ventilation led by natural convection in the ventilated chamber and the protection from solar radiation given by the outer layer of the façade. This research investigates the thermal behavior of an opaque naturally ventilated façade through Computation Fluid Dynamics (CFD) simulations during summer days. The CFD simulations have been performed in order to analyze the behavior of DSF components under different wind conditions in the summer period, utilizing the weather data of Catania city (Italy). For the different investigated scenarios, the authors have calculated the temperature and air velocity profiles inside the air gap of the façade, highlighting the different effects of buoyancy and wind forces. The results show that the wind forces in conjunction with the buoyancy forces affect significantly the performance of OVF components. Further, the reduction of the heat flux during the summer period has been evaluated by comparing the thermodynamic performance of a naturally ventilated and an unventilated façade with the same geometry and thermo-physical characteristics. The behavior of the naturally ventilated façade is an improvement in terms of passive cooling of the building compared to the non-ventilated façade since it allows the peak load to be shifted whilst offering energy savings in the range of 47% to 51% depending on climate.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.enbuild.2016.04.035</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-7788
ispartof Energy and buildings, 2016-06, Vol.122, p.131-139
issn 0378-7788
language eng
recordid cdi_proquest_miscellaneous_1816085550
source Elsevier ScienceDirect Journals Complete
subjects Buoyancy
Computational fluid dynamics
Computer simulation
Cooling
Cooling load
Facades
Fluid dynamic
Mathematical models
Natural ventilation
Opaque ventilated facades
Reduction
Summer
Wind scenario
title Thermodynamic analysis of ventilated façades under different wind conditions in summer period
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T04%3A52%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Thermodynamic%20analysis%20of%20ventilated%20fa%C3%A7ades%20under%20different%20wind%20conditions%20in%20summer%20period&rft.jtitle=Energy%20and%20buildings&rft.au=Gagliano,%20A.&rft.date=2016-06-15&rft.volume=122&rft.spage=131&rft.epage=139&rft.pages=131-139&rft.issn=0378-7788&rft_id=info:doi/10.1016/j.enbuild.2016.04.035&rft_dat=%3Cproquest_cross%3E1808678485%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1808678485&rft_id=info:pmid/&rft_els_id=S0378778816302882&rfr_iscdi=true