Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds

We have measured 10 and 20 mT magnetic fields using NV centers in nanodiamonds and have demonstrated that the accuracy of these measurements is about 20 [mu]T. This value is an order of magnitude larger than the precision defined by random fluctuations in the measurements. The presented analysis ind...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Optical Society of America. B, Optical physics Optical physics, 2016-03, Vol.33 (3), p.B19-B27
Hauptverfasser: Aman, Haroon, Plakhotnik, Taras
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page B27
container_issue 3
container_start_page B19
container_title Journal of the Optical Society of America. B, Optical physics
container_volume 33
creator Aman, Haroon
Plakhotnik, Taras
description We have measured 10 and 20 mT magnetic fields using NV centers in nanodiamonds and have demonstrated that the accuracy of these measurements is about 20 [mu]T. This value is an order of magnitude larger than the precision defined by random fluctuations in the measurements. The presented analysis indicates that the 20 [mu]T systematic errors at such fields are intrinsic to the nanodiamonds. The possible reason for this error is coupling of NV centers with paramagnetic entities in the nanodiamonds such as other NV centers, super(13) C, and super(14) N nuclei.
doi_str_mv 10.1364/JOSAB.33.000B19
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1816077910</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1816077910</sourcerecordid><originalsourceid>FETCH-LOGICAL-c274t-c377559e42a583d69655b366a2d9292aec5aa4608a4c645eefef69eb59ac208b3</originalsourceid><addsrcrecordid>eNotkDtPwzAURi0EEqUws3pkSet34rGteKpSB2BE1q1zU4ISp9gJUv89KWX6lvOd4RByy9mMS6PmL5vXxXIm5YwxtuT2jEy4FiwrtGLnZMJyxTIphLokVyl9jYxiQkzIx8L7IYI_0DrQ_hNpi5CGiC2GnnYVbWEXsK89rWpsykSHVIcdDXUfux2G7Ac8hPHsRxxjOkoChK6soe1Cma7JRQVNwpv_nZL3h_u31VO23jw-rxbrzItc9ZmXea61RSVAF7I01mi9lcaAKK2wAtBrAGVYAcobpRErrIzFrbbgBSu2ckruTt597L4HTL1r6-SxaSBgNyTHC25YnlvORnR-Qn3sUopYuX2sW4gHx5k7hnR_IZ2U7hRS_gJ1WGd-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1816077910</pqid></control><display><type>article</type><title>Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds</title><source>Optica Publishing Group Journals</source><creator>Aman, Haroon ; Plakhotnik, Taras</creator><creatorcontrib>Aman, Haroon ; Plakhotnik, Taras</creatorcontrib><description>We have measured 10 and 20 mT magnetic fields using NV centers in nanodiamonds and have demonstrated that the accuracy of these measurements is about 20 [mu]T. This value is an order of magnitude larger than the precision defined by random fluctuations in the measurements. The presented analysis indicates that the 20 [mu]T systematic errors at such fields are intrinsic to the nanodiamonds. The possible reason for this error is coupling of NV centers with paramagnetic entities in the nanodiamonds such as other NV centers, super(13) C, and super(14) N nuclei.</description><identifier>ISSN: 0740-3224</identifier><identifier>EISSN: 1520-8540</identifier><identifier>DOI: 10.1364/JOSAB.33.000B19</identifier><language>eng</language><subject>Americas ; Coupling ; Errors ; Fluctuation ; Magnetic fields ; Nanostructure ; Nuclei ; Systematic errors</subject><ispartof>Journal of the Optical Society of America. B, Optical physics, 2016-03, Vol.33 (3), p.B19-B27</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c274t-c377559e42a583d69655b366a2d9292aec5aa4608a4c645eefef69eb59ac208b3</citedby><cites>FETCH-LOGICAL-c274t-c377559e42a583d69655b366a2d9292aec5aa4608a4c645eefef69eb59ac208b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,3258,27924,27925</link.rule.ids></links><search><creatorcontrib>Aman, Haroon</creatorcontrib><creatorcontrib>Plakhotnik, Taras</creatorcontrib><title>Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds</title><title>Journal of the Optical Society of America. B, Optical physics</title><description>We have measured 10 and 20 mT magnetic fields using NV centers in nanodiamonds and have demonstrated that the accuracy of these measurements is about 20 [mu]T. This value is an order of magnitude larger than the precision defined by random fluctuations in the measurements. The presented analysis indicates that the 20 [mu]T systematic errors at such fields are intrinsic to the nanodiamonds. The possible reason for this error is coupling of NV centers with paramagnetic entities in the nanodiamonds such as other NV centers, super(13) C, and super(14) N nuclei.</description><subject>Americas</subject><subject>Coupling</subject><subject>Errors</subject><subject>Fluctuation</subject><subject>Magnetic fields</subject><subject>Nanostructure</subject><subject>Nuclei</subject><subject>Systematic errors</subject><issn>0740-3224</issn><issn>1520-8540</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNotkDtPwzAURi0EEqUws3pkSet34rGteKpSB2BE1q1zU4ISp9gJUv89KWX6lvOd4RByy9mMS6PmL5vXxXIm5YwxtuT2jEy4FiwrtGLnZMJyxTIphLokVyl9jYxiQkzIx8L7IYI_0DrQ_hNpi5CGiC2GnnYVbWEXsK89rWpsykSHVIcdDXUfux2G7Ac8hPHsRxxjOkoChK6soe1Cma7JRQVNwpv_nZL3h_u31VO23jw-rxbrzItc9ZmXea61RSVAF7I01mi9lcaAKK2wAtBrAGVYAcobpRErrIzFrbbgBSu2ckruTt597L4HTL1r6-SxaSBgNyTHC25YnlvORnR-Qn3sUopYuX2sW4gHx5k7hnR_IZ2U7hRS_gJ1WGd-</recordid><startdate>20160301</startdate><enddate>20160301</enddate><creator>Aman, Haroon</creator><creator>Plakhotnik, Taras</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20160301</creationdate><title>Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds</title><author>Aman, Haroon ; Plakhotnik, Taras</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c274t-c377559e42a583d69655b366a2d9292aec5aa4608a4c645eefef69eb59ac208b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Americas</topic><topic>Coupling</topic><topic>Errors</topic><topic>Fluctuation</topic><topic>Magnetic fields</topic><topic>Nanostructure</topic><topic>Nuclei</topic><topic>Systematic errors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aman, Haroon</creatorcontrib><creatorcontrib>Plakhotnik, Taras</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of the Optical Society of America. B, Optical physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aman, Haroon</au><au>Plakhotnik, Taras</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds</atitle><jtitle>Journal of the Optical Society of America. B, Optical physics</jtitle><date>2016-03-01</date><risdate>2016</risdate><volume>33</volume><issue>3</issue><spage>B19</spage><epage>B27</epage><pages>B19-B27</pages><issn>0740-3224</issn><eissn>1520-8540</eissn><abstract>We have measured 10 and 20 mT magnetic fields using NV centers in nanodiamonds and have demonstrated that the accuracy of these measurements is about 20 [mu]T. This value is an order of magnitude larger than the precision defined by random fluctuations in the measurements. The presented analysis indicates that the 20 [mu]T systematic errors at such fields are intrinsic to the nanodiamonds. The possible reason for this error is coupling of NV centers with paramagnetic entities in the nanodiamonds such as other NV centers, super(13) C, and super(14) N nuclei.</abstract><doi>10.1364/JOSAB.33.000B19</doi></addata></record>
fulltext fulltext
identifier ISSN: 0740-3224
ispartof Journal of the Optical Society of America. B, Optical physics, 2016-03, Vol.33 (3), p.B19-B27
issn 0740-3224
1520-8540
language eng
recordid cdi_proquest_miscellaneous_1816077910
source Optica Publishing Group Journals
subjects Americas
Coupling
Errors
Fluctuation
Magnetic fields
Nanostructure
Nuclei
Systematic errors
title Accuracy in the measurement of magnetic fields using nitrogen-vacancy centers in nanodiamonds
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T22%3A23%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20in%20the%20measurement%20of%20magnetic%20fields%20using%20nitrogen-vacancy%20centers%20in%20nanodiamonds&rft.jtitle=Journal%20of%20the%20Optical%20Society%20of%20America.%20B,%20Optical%20physics&rft.au=Aman,%20Haroon&rft.date=2016-03-01&rft.volume=33&rft.issue=3&rft.spage=B19&rft.epage=B27&rft.pages=B19-B27&rft.issn=0740-3224&rft.eissn=1520-8540&rft_id=info:doi/10.1364/JOSAB.33.000B19&rft_dat=%3Cproquest_cross%3E1816077910%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1816077910&rft_id=info:pmid/&rfr_iscdi=true