Use of effective dose

International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of the ICRP 2016-06, Vol.45 (1_suppl), p.215-224
Hauptverfasser: Harrison, J.D., Balonov, M., Martin, C.J., Ortiz Lopez, P., Menzel, H-G., Simmonds, J.R., Smith-Bindman, R., Wakeford, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 224
container_issue 1_suppl
container_start_page 215
container_title Annals of the ICRP
container_volume 45
creator Harrison, J.D.
Balonov, M.
Martin, C.J.
Ortiz Lopez, P.
Menzel, H-G.
Simmonds, J.R.
Smith-Bindman, R.
Wakeford, R.
description International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of protection principles. However, questions have arisen regarding practical applications, and a Task Group has been set up to consider issues of concern. This paper focusses on two key proposals developed by the Task Group that are under consideration by ICRP: (1) confusion will be avoided if equivalent dose is no longer used as a protection quantity, but regarded as an intermediate step in the calculation of effective dose. It would be more appropriate for limits for the avoidance of deterministic effects to the hands and feet, lens of the eye, and skin, to be set in terms of the quantity, absorbed dose (Gy) rather than equivalent dose (Sv). (2) Effective dose is in widespread use in medical practice as a measure of risk, thereby going beyond its intended purpose. While doses incurred at low levels of exposure may be measured or assessed with reasonable reliability, health effects have not been demonstrated reliably at such levels but are inferred. However, bearing in mind the uncertainties associated with risk projection to low doses or low dose rates, it may be considered reasonable to use effective dose as a rough indicator of possible risk, with the additional consideration of variation in risk with age, sex and population group.
doi_str_mv 10.1177/0146645316634566
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1816040485</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0146645316634566</sage_id><sourcerecordid>1789032579</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4466-7ff6edf500aadb4fa0255e15c87b5bd2f60067ee0a4311f56db4f1494ca0020c3</originalsourceid><addsrcrecordid>eNqFkM9Lw0AQhRdRbK0eBU_So5foTLI7uzlK8RcUvFjwtmw2s5LSNjXbCP73JqR6EMTTHN733sAnxAXCNaLWN4CSSKoMiTKpiA7EGI1Ok5zy10Mx7uOkz0fiJMYlAEjK9LEYpZQbMABjcb6IPK3DlENgv6s-eFrWkU_FUXCryGf7OxGL-7uX2WMyf354mt3OEy-7x4kOgbgMCsC5spDBQaoUo_JGF6oo00AApJnByQwxKOohlLn0DiAFn03E1bC7ber3luPOrqvoebVyG67baNEggQRp1P-oNjlkqdJ5h8KA-qaOseFgt021ds2nRbC9N_vbW1e53K-3xZrLn8K3qA5IBiC6N7bLum02nZi_B78AO09xqQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1789032579</pqid></control><display><type>article</type><title>Use of effective dose</title><source>Access via SAGE</source><source>MEDLINE</source><creator>Harrison, J.D. ; Balonov, M. ; Martin, C.J. ; Ortiz Lopez, P. ; Menzel, H-G. ; Simmonds, J.R. ; Smith-Bindman, R. ; Wakeford, R.</creator><creatorcontrib>Harrison, J.D. ; Balonov, M. ; Martin, C.J. ; Ortiz Lopez, P. ; Menzel, H-G. ; Simmonds, J.R. ; Smith-Bindman, R. ; Wakeford, R.</creatorcontrib><description>International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of protection principles. However, questions have arisen regarding practical applications, and a Task Group has been set up to consider issues of concern. This paper focusses on two key proposals developed by the Task Group that are under consideration by ICRP: (1) confusion will be avoided if equivalent dose is no longer used as a protection quantity, but regarded as an intermediate step in the calculation of effective dose. It would be more appropriate for limits for the avoidance of deterministic effects to the hands and feet, lens of the eye, and skin, to be set in terms of the quantity, absorbed dose (Gy) rather than equivalent dose (Sv). (2) Effective dose is in widespread use in medical practice as a measure of risk, thereby going beyond its intended purpose. While doses incurred at low levels of exposure may be measured or assessed with reasonable reliability, health effects have not been demonstrated reliably at such levels but are inferred. However, bearing in mind the uncertainties associated with risk projection to low doses or low dose rates, it may be considered reasonable to use effective dose as a rough indicator of possible risk, with the additional consideration of variation in risk with age, sex and population group.</description><identifier>ISSN: 0146-6453</identifier><identifier>EISSN: 1872-969X</identifier><identifier>DOI: 10.1177/0146645316634566</identifier><identifier>PMID: 26980800</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Dosage ; Equivalence ; Eyes ; Humans ; Medical ; Projection ; Proposals ; Radiation Dosage ; Radiation Exposure ; Radiation Protection ; Relative Biological Effectiveness ; Reproducibility of Results ; Risk ; Risk Assessment ; Tasks</subject><ispartof>Annals of the ICRP, 2016-06, Vol.45 (1_suppl), p.215-224</ispartof><rights>The International Society for Prosthetics and Orthotics</rights><rights>The International Society for Prosthetics and Orthotics.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4466-7ff6edf500aadb4fa0255e15c87b5bd2f60067ee0a4311f56db4f1494ca0020c3</citedby><cites>FETCH-LOGICAL-c4466-7ff6edf500aadb4fa0255e15c87b5bd2f60067ee0a4311f56db4f1494ca0020c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/0146645316634566$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/0146645316634566$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26980800$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Harrison, J.D.</creatorcontrib><creatorcontrib>Balonov, M.</creatorcontrib><creatorcontrib>Martin, C.J.</creatorcontrib><creatorcontrib>Ortiz Lopez, P.</creatorcontrib><creatorcontrib>Menzel, H-G.</creatorcontrib><creatorcontrib>Simmonds, J.R.</creatorcontrib><creatorcontrib>Smith-Bindman, R.</creatorcontrib><creatorcontrib>Wakeford, R.</creatorcontrib><title>Use of effective dose</title><title>Annals of the ICRP</title><addtitle>Ann ICRP</addtitle><description>International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of protection principles. However, questions have arisen regarding practical applications, and a Task Group has been set up to consider issues of concern. This paper focusses on two key proposals developed by the Task Group that are under consideration by ICRP: (1) confusion will be avoided if equivalent dose is no longer used as a protection quantity, but regarded as an intermediate step in the calculation of effective dose. It would be more appropriate for limits for the avoidance of deterministic effects to the hands and feet, lens of the eye, and skin, to be set in terms of the quantity, absorbed dose (Gy) rather than equivalent dose (Sv). (2) Effective dose is in widespread use in medical practice as a measure of risk, thereby going beyond its intended purpose. While doses incurred at low levels of exposure may be measured or assessed with reasonable reliability, health effects have not been demonstrated reliably at such levels but are inferred. However, bearing in mind the uncertainties associated with risk projection to low doses or low dose rates, it may be considered reasonable to use effective dose as a rough indicator of possible risk, with the additional consideration of variation in risk with age, sex and population group.</description><subject>Dosage</subject><subject>Equivalence</subject><subject>Eyes</subject><subject>Humans</subject><subject>Medical</subject><subject>Projection</subject><subject>Proposals</subject><subject>Radiation Dosage</subject><subject>Radiation Exposure</subject><subject>Radiation Protection</subject><subject>Relative Biological Effectiveness</subject><subject>Reproducibility of Results</subject><subject>Risk</subject><subject>Risk Assessment</subject><subject>Tasks</subject><issn>0146-6453</issn><issn>1872-969X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkM9Lw0AQhRdRbK0eBU_So5foTLI7uzlK8RcUvFjwtmw2s5LSNjXbCP73JqR6EMTTHN733sAnxAXCNaLWN4CSSKoMiTKpiA7EGI1Ok5zy10Mx7uOkz0fiJMYlAEjK9LEYpZQbMABjcb6IPK3DlENgv6s-eFrWkU_FUXCryGf7OxGL-7uX2WMyf354mt3OEy-7x4kOgbgMCsC5spDBQaoUo_JGF6oo00AApJnByQwxKOohlLn0DiAFn03E1bC7ber3luPOrqvoebVyG67baNEggQRp1P-oNjlkqdJ5h8KA-qaOseFgt021ds2nRbC9N_vbW1e53K-3xZrLn8K3qA5IBiC6N7bLum02nZi_B78AO09xqQ</recordid><startdate>201606</startdate><enddate>201606</enddate><creator>Harrison, J.D.</creator><creator>Balonov, M.</creator><creator>Martin, C.J.</creator><creator>Ortiz Lopez, P.</creator><creator>Menzel, H-G.</creator><creator>Simmonds, J.R.</creator><creator>Smith-Bindman, R.</creator><creator>Wakeford, R.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>201606</creationdate><title>Use of effective dose</title><author>Harrison, J.D. ; Balonov, M. ; Martin, C.J. ; Ortiz Lopez, P. ; Menzel, H-G. ; Simmonds, J.R. ; Smith-Bindman, R. ; Wakeford, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4466-7ff6edf500aadb4fa0255e15c87b5bd2f60067ee0a4311f56db4f1494ca0020c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Dosage</topic><topic>Equivalence</topic><topic>Eyes</topic><topic>Humans</topic><topic>Medical</topic><topic>Projection</topic><topic>Proposals</topic><topic>Radiation Dosage</topic><topic>Radiation Exposure</topic><topic>Radiation Protection</topic><topic>Relative Biological Effectiveness</topic><topic>Reproducibility of Results</topic><topic>Risk</topic><topic>Risk Assessment</topic><topic>Tasks</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Harrison, J.D.</creatorcontrib><creatorcontrib>Balonov, M.</creatorcontrib><creatorcontrib>Martin, C.J.</creatorcontrib><creatorcontrib>Ortiz Lopez, P.</creatorcontrib><creatorcontrib>Menzel, H-G.</creatorcontrib><creatorcontrib>Simmonds, J.R.</creatorcontrib><creatorcontrib>Smith-Bindman, R.</creatorcontrib><creatorcontrib>Wakeford, R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Annals of the ICRP</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harrison, J.D.</au><au>Balonov, M.</au><au>Martin, C.J.</au><au>Ortiz Lopez, P.</au><au>Menzel, H-G.</au><au>Simmonds, J.R.</au><au>Smith-Bindman, R.</au><au>Wakeford, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of effective dose</atitle><jtitle>Annals of the ICRP</jtitle><addtitle>Ann ICRP</addtitle><date>2016-06</date><risdate>2016</risdate><volume>45</volume><issue>1_suppl</issue><spage>215</spage><epage>224</epage><pages>215-224</pages><issn>0146-6453</issn><eissn>1872-969X</eissn><abstract>International Commission on Radiological Protection (ICRP) Publication 103 provided a detailed explanation of the purpose and use of effective dose and equivalent dose to individual organs and tissues. Effective dose has proven to be a valuable and robust quantity for use in the implementation of protection principles. However, questions have arisen regarding practical applications, and a Task Group has been set up to consider issues of concern. This paper focusses on two key proposals developed by the Task Group that are under consideration by ICRP: (1) confusion will be avoided if equivalent dose is no longer used as a protection quantity, but regarded as an intermediate step in the calculation of effective dose. It would be more appropriate for limits for the avoidance of deterministic effects to the hands and feet, lens of the eye, and skin, to be set in terms of the quantity, absorbed dose (Gy) rather than equivalent dose (Sv). (2) Effective dose is in widespread use in medical practice as a measure of risk, thereby going beyond its intended purpose. While doses incurred at low levels of exposure may be measured or assessed with reasonable reliability, health effects have not been demonstrated reliably at such levels but are inferred. However, bearing in mind the uncertainties associated with risk projection to low doses or low dose rates, it may be considered reasonable to use effective dose as a rough indicator of possible risk, with the additional consideration of variation in risk with age, sex and population group.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>26980800</pmid><doi>10.1177/0146645316634566</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0146-6453
ispartof Annals of the ICRP, 2016-06, Vol.45 (1_suppl), p.215-224
issn 0146-6453
1872-969X
language eng
recordid cdi_proquest_miscellaneous_1816040485
source Access via SAGE; MEDLINE
subjects Dosage
Equivalence
Eyes
Humans
Medical
Projection
Proposals
Radiation Dosage
Radiation Exposure
Radiation Protection
Relative Biological Effectiveness
Reproducibility of Results
Risk
Risk Assessment
Tasks
title Use of effective dose
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T14%3A01%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20effective%20dose&rft.jtitle=Annals%20of%20the%20ICRP&rft.au=Harrison,%20J.D.&rft.date=2016-06&rft.volume=45&rft.issue=1_suppl&rft.spage=215&rft.epage=224&rft.pages=215-224&rft.issn=0146-6453&rft.eissn=1872-969X&rft_id=info:doi/10.1177/0146645316634566&rft_dat=%3Cproquest_cross%3E1789032579%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1789032579&rft_id=info:pmid/26980800&rft_sage_id=10.1177_0146645316634566&rfr_iscdi=true