Normal gait speed, grip strength and thirty seconds chair stand test among older Indians

Abstract Introduction Gait speed, maximum grip strength and thirty seconds chair stand test are quick, reliable measures of functional capacity in older adults. The objective of this study was to develop normative data of the said parameters, which is lacking in older Indians. Methodology In a cross...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of gerontology and geriatrics 2016-11, Vol.67, p.171-178
Hauptverfasser: Gunasekaran, Venugopalan, Banerjee, Joyita, Dwivedi, Sada Nand, Upadhyay, Ashish Datt, Chatterjee, Prashun, Dey, Aparajit Ballav
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 178
container_issue
container_start_page 171
container_title Archives of gerontology and geriatrics
container_volume 67
creator Gunasekaran, Venugopalan
Banerjee, Joyita
Dwivedi, Sada Nand
Upadhyay, Ashish Datt
Chatterjee, Prashun
Dey, Aparajit Ballav
description Abstract Introduction Gait speed, maximum grip strength and thirty seconds chair stand test are quick, reliable measures of functional capacity in older adults. The objective of this study was to develop normative data of the said parameters, which is lacking in older Indians. Methodology In a cross sectional study, 723 participants of ≥60 years without any morbidity, were recruited with written consent at Geriatric Medicine clinic of All India Institute of Medical sciences, New Delhi. Time taken to walk comfortably (4 m) was taken as Gait speed. Maximum grip strength was assessed by using dynamometer by pressing it for 3 times in each hand, and the best of six values noted. Thirty second chair stand was assessed by the number of repetitions to stand and sit from a chair in thirty second. Result The Cut-off (25th percentile) of gait speed for both male and female in all age group was 0.6 m/s. The Cut-off for maximum grip strength in 60–65 years, 66–70 years and >70 years for male were 20, 15 and 15 and for females were 8, 6 and 6 in kg, respectively. The Cut-off for thirty second chair stand test in 60–65 years, 66–70 years and >70 years for male were 10, 9 and 8 and for females was 8, 8 and 7, respectively. Conclusion These normative data would be useful to the clinicians and researcher as Indian reference value, which is less as compared to western data. Community based multi-centre study is needed.
doi_str_mv 10.1016/j.archger.2016.08.003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1815975316</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S016749431630142X</els_id><sourcerecordid>1815975316</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-d66866b8ed512e1cf9503a7d19d286a4d2ec670b400d472a084e2007938457203</originalsourceid><addsrcrecordid>eNqFkU1vEzEQhi1ERdPCTwD5yIFdxl6v7b2AqgpKpaocAKk3y7EnG4ddb7A3lfLvcUjg0Aun0Wjedz6eIeQ1g5oBk-83tU1u3WOqeUlr0DVA84wsmFa8kp2Sz8miFFQlOtGck4ucNwAggMsX5JyrtuWtbhbk4X5Kox1ob8NM8xbRv6N9Clua54Sxn9fURk_ndUjznmZ0U_SZurUNqSj-lDDP1I5T7Ok0eEz0NvpgY35JzlZ2yPjqFC_Jj8-fvl9_qe6-3txeX91VTnCYKy-llnKp0beMI3OrroXGKs86z7W0wnN0UsFSAHihuAUtkAOortGiVRyaS_L22Hebpl-7sowZQ3Y4DDbitMuGadZ2qm2YLNL2KHVpyjnhymxTGG3aGwbmANVszAmqOUA1oE2BWnxvTiN2yxH9P9dfikXw8SjAcuhjKPbsAkaHPiR0s_FT-O-ID086uCHE4OzwE_eYN9MuxULRMJO5AfPt8NnDY8tVwAR_aH4Dj6Wetg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1815975316</pqid></control><display><type>article</type><title>Normal gait speed, grip strength and thirty seconds chair stand test among older Indians</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Gunasekaran, Venugopalan ; Banerjee, Joyita ; Dwivedi, Sada Nand ; Upadhyay, Ashish Datt ; Chatterjee, Prashun ; Dey, Aparajit Ballav</creator><creatorcontrib>Gunasekaran, Venugopalan ; Banerjee, Joyita ; Dwivedi, Sada Nand ; Upadhyay, Ashish Datt ; Chatterjee, Prashun ; Dey, Aparajit Ballav</creatorcontrib><description>Abstract Introduction Gait speed, maximum grip strength and thirty seconds chair stand test are quick, reliable measures of functional capacity in older adults. The objective of this study was to develop normative data of the said parameters, which is lacking in older Indians. Methodology In a cross sectional study, 723 participants of ≥60 years without any morbidity, were recruited with written consent at Geriatric Medicine clinic of All India Institute of Medical sciences, New Delhi. Time taken to walk comfortably (4 m) was taken as Gait speed. Maximum grip strength was assessed by using dynamometer by pressing it for 3 times in each hand, and the best of six values noted. Thirty second chair stand was assessed by the number of repetitions to stand and sit from a chair in thirty second. Result The Cut-off (25th percentile) of gait speed for both male and female in all age group was 0.6 m/s. The Cut-off for maximum grip strength in 60–65 years, 66–70 years and &gt;70 years for male were 20, 15 and 15 and for females were 8, 6 and 6 in kg, respectively. The Cut-off for thirty second chair stand test in 60–65 years, 66–70 years and &gt;70 years for male were 10, 9 and 8 and for females was 8, 8 and 7, respectively. Conclusion These normative data would be useful to the clinicians and researcher as Indian reference value, which is less as compared to western data. Community based multi-centre study is needed.</description><identifier>ISSN: 0167-4943</identifier><identifier>EISSN: 1872-6976</identifier><identifier>DOI: 10.1016/j.archger.2016.08.003</identifier><identifier>PMID: 27552583</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Aged ; Cross-Sectional Studies ; Exercise Test ; Female ; Gait - physiology ; Geriatric Assessment - methods ; Humans ; India ; Internal Medicine ; Male ; Middle Aged ; Reference Values ; Task Performance and Analysis ; Time Factors ; Walking Speed - physiology</subject><ispartof>Archives of gerontology and geriatrics, 2016-11, Vol.67, p.171-178</ispartof><rights>Elsevier Ireland Ltd</rights><rights>2016 Elsevier Ireland Ltd</rights><rights>Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-d66866b8ed512e1cf9503a7d19d286a4d2ec670b400d472a084e2007938457203</citedby><cites>FETCH-LOGICAL-c420t-d66866b8ed512e1cf9503a7d19d286a4d2ec670b400d472a084e2007938457203</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.archger.2016.08.003$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27552583$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gunasekaran, Venugopalan</creatorcontrib><creatorcontrib>Banerjee, Joyita</creatorcontrib><creatorcontrib>Dwivedi, Sada Nand</creatorcontrib><creatorcontrib>Upadhyay, Ashish Datt</creatorcontrib><creatorcontrib>Chatterjee, Prashun</creatorcontrib><creatorcontrib>Dey, Aparajit Ballav</creatorcontrib><title>Normal gait speed, grip strength and thirty seconds chair stand test among older Indians</title><title>Archives of gerontology and geriatrics</title><addtitle>Arch Gerontol Geriatr</addtitle><description>Abstract Introduction Gait speed, maximum grip strength and thirty seconds chair stand test are quick, reliable measures of functional capacity in older adults. The objective of this study was to develop normative data of the said parameters, which is lacking in older Indians. Methodology In a cross sectional study, 723 participants of ≥60 years without any morbidity, were recruited with written consent at Geriatric Medicine clinic of All India Institute of Medical sciences, New Delhi. Time taken to walk comfortably (4 m) was taken as Gait speed. Maximum grip strength was assessed by using dynamometer by pressing it for 3 times in each hand, and the best of six values noted. Thirty second chair stand was assessed by the number of repetitions to stand and sit from a chair in thirty second. Result The Cut-off (25th percentile) of gait speed for both male and female in all age group was 0.6 m/s. The Cut-off for maximum grip strength in 60–65 years, 66–70 years and &gt;70 years for male were 20, 15 and 15 and for females were 8, 6 and 6 in kg, respectively. The Cut-off for thirty second chair stand test in 60–65 years, 66–70 years and &gt;70 years for male were 10, 9 and 8 and for females was 8, 8 and 7, respectively. Conclusion These normative data would be useful to the clinicians and researcher as Indian reference value, which is less as compared to western data. Community based multi-centre study is needed.</description><subject>Aged</subject><subject>Cross-Sectional Studies</subject><subject>Exercise Test</subject><subject>Female</subject><subject>Gait - physiology</subject><subject>Geriatric Assessment - methods</subject><subject>Humans</subject><subject>India</subject><subject>Internal Medicine</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Reference Values</subject><subject>Task Performance and Analysis</subject><subject>Time Factors</subject><subject>Walking Speed - physiology</subject><issn>0167-4943</issn><issn>1872-6976</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1vEzEQhi1ERdPCTwD5yIFdxl6v7b2AqgpKpaocAKk3y7EnG4ddb7A3lfLvcUjg0Aun0Wjedz6eIeQ1g5oBk-83tU1u3WOqeUlr0DVA84wsmFa8kp2Sz8miFFQlOtGck4ucNwAggMsX5JyrtuWtbhbk4X5Kox1ob8NM8xbRv6N9Clua54Sxn9fURk_ndUjznmZ0U_SZurUNqSj-lDDP1I5T7Ok0eEz0NvpgY35JzlZ2yPjqFC_Jj8-fvl9_qe6-3txeX91VTnCYKy-llnKp0beMI3OrroXGKs86z7W0wnN0UsFSAHihuAUtkAOortGiVRyaS_L22Hebpl-7sowZQ3Y4DDbitMuGadZ2qm2YLNL2KHVpyjnhymxTGG3aGwbmANVszAmqOUA1oE2BWnxvTiN2yxH9P9dfikXw8SjAcuhjKPbsAkaHPiR0s_FT-O-ID086uCHE4OzwE_eYN9MuxULRMJO5AfPt8NnDY8tVwAR_aH4Dj6Wetg</recordid><startdate>20161101</startdate><enddate>20161101</enddate><creator>Gunasekaran, Venugopalan</creator><creator>Banerjee, Joyita</creator><creator>Dwivedi, Sada Nand</creator><creator>Upadhyay, Ashish Datt</creator><creator>Chatterjee, Prashun</creator><creator>Dey, Aparajit Ballav</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20161101</creationdate><title>Normal gait speed, grip strength and thirty seconds chair stand test among older Indians</title><author>Gunasekaran, Venugopalan ; Banerjee, Joyita ; Dwivedi, Sada Nand ; Upadhyay, Ashish Datt ; Chatterjee, Prashun ; Dey, Aparajit Ballav</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-d66866b8ed512e1cf9503a7d19d286a4d2ec670b400d472a084e2007938457203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Aged</topic><topic>Cross-Sectional Studies</topic><topic>Exercise Test</topic><topic>Female</topic><topic>Gait - physiology</topic><topic>Geriatric Assessment - methods</topic><topic>Humans</topic><topic>India</topic><topic>Internal Medicine</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Reference Values</topic><topic>Task Performance and Analysis</topic><topic>Time Factors</topic><topic>Walking Speed - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gunasekaran, Venugopalan</creatorcontrib><creatorcontrib>Banerjee, Joyita</creatorcontrib><creatorcontrib>Dwivedi, Sada Nand</creatorcontrib><creatorcontrib>Upadhyay, Ashish Datt</creatorcontrib><creatorcontrib>Chatterjee, Prashun</creatorcontrib><creatorcontrib>Dey, Aparajit Ballav</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Archives of gerontology and geriatrics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gunasekaran, Venugopalan</au><au>Banerjee, Joyita</au><au>Dwivedi, Sada Nand</au><au>Upadhyay, Ashish Datt</au><au>Chatterjee, Prashun</au><au>Dey, Aparajit Ballav</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Normal gait speed, grip strength and thirty seconds chair stand test among older Indians</atitle><jtitle>Archives of gerontology and geriatrics</jtitle><addtitle>Arch Gerontol Geriatr</addtitle><date>2016-11-01</date><risdate>2016</risdate><volume>67</volume><spage>171</spage><epage>178</epage><pages>171-178</pages><issn>0167-4943</issn><eissn>1872-6976</eissn><abstract>Abstract Introduction Gait speed, maximum grip strength and thirty seconds chair stand test are quick, reliable measures of functional capacity in older adults. The objective of this study was to develop normative data of the said parameters, which is lacking in older Indians. Methodology In a cross sectional study, 723 participants of ≥60 years without any morbidity, were recruited with written consent at Geriatric Medicine clinic of All India Institute of Medical sciences, New Delhi. Time taken to walk comfortably (4 m) was taken as Gait speed. Maximum grip strength was assessed by using dynamometer by pressing it for 3 times in each hand, and the best of six values noted. Thirty second chair stand was assessed by the number of repetitions to stand and sit from a chair in thirty second. Result The Cut-off (25th percentile) of gait speed for both male and female in all age group was 0.6 m/s. The Cut-off for maximum grip strength in 60–65 years, 66–70 years and &gt;70 years for male were 20, 15 and 15 and for females were 8, 6 and 6 in kg, respectively. The Cut-off for thirty second chair stand test in 60–65 years, 66–70 years and &gt;70 years for male were 10, 9 and 8 and for females was 8, 8 and 7, respectively. Conclusion These normative data would be useful to the clinicians and researcher as Indian reference value, which is less as compared to western data. Community based multi-centre study is needed.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>27552583</pmid><doi>10.1016/j.archger.2016.08.003</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0167-4943
ispartof Archives of gerontology and geriatrics, 2016-11, Vol.67, p.171-178
issn 0167-4943
1872-6976
language eng
recordid cdi_proquest_miscellaneous_1815975316
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Aged
Cross-Sectional Studies
Exercise Test
Female
Gait - physiology
Geriatric Assessment - methods
Humans
India
Internal Medicine
Male
Middle Aged
Reference Values
Task Performance and Analysis
Time Factors
Walking Speed - physiology
title Normal gait speed, grip strength and thirty seconds chair stand test among older Indians
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T01%3A36%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Normal%20gait%20speed,%20grip%20strength%20and%20thirty%20seconds%20chair%20stand%20test%20among%20older%20Indians&rft.jtitle=Archives%20of%20gerontology%20and%20geriatrics&rft.au=Gunasekaran,%20Venugopalan&rft.date=2016-11-01&rft.volume=67&rft.spage=171&rft.epage=178&rft.pages=171-178&rft.issn=0167-4943&rft.eissn=1872-6976&rft_id=info:doi/10.1016/j.archger.2016.08.003&rft_dat=%3Cproquest_cross%3E1815975316%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1815975316&rft_id=info:pmid/27552583&rft_els_id=1_s2_0_S016749431630142X&rfr_iscdi=true