Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique

Introduction Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. Methods This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In br...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical endoscopy 2016-09, Vol.30 (9), p.4150-4151
Hauptverfasser: Melich, George, Pai, Ajit, Balachandran, Banujan, Marecik, Slawomir J., Prasad, Leela M., Park, John J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4151
container_issue 9
container_start_page 4150
container_title Surgical endoscopy
container_volume 30
creator Melich, George
Pai, Ajit
Balachandran, Banujan
Marecik, Slawomir J.
Prasad, Leela M.
Park, John J.
description Introduction Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. Methods This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents—10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). Results The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9–3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Conclusions Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [ 1 ], there is no published account of bridging an enterocutaneous fistula
doi_str_mv 10.1007/s00464-015-4636-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1812886774</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1812886774</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-ca230ee999afd18a462c6da97986e713ea725807bf1fd1d68cc6a8b69458dc563</originalsourceid><addsrcrecordid>eNp1kElLBDEUhIMozrj8AC8S8OKlNVtnOcrgBoIXPYdMOq099CRjlsP8e6OtIoKnd6iv6hUFwAlGFxghcZkQYpw1CLcN45Q37Q6YY0ZJQwiWu2COFEUNEYrNwEFKK1Rxhdt9MCOiRVhQNAfP174LyYbNYKENPscwwtBD57OLwZZsvAslwX5IuYwGLrewK2aEg88lpZKs2-TBv8CUqwNmZ1_98FbcEdjrzZjc8dc9BM8310-Lu-bh8fZ-cfXQWCpIbqwhFDmnlDJ9h6VhnFjeGSWU5E5g6owgrURi2eOqd1xay41ccsVa2dmW00NwPuVuYqhvU9broXYax6m2xhITKbkQrKJnf9BVKNHXdp8UR5QyXCk8UTaGlKLr9SYOaxO3GiP9sbmeNtd1c_2xuW6r5_QruSzXrvtxfI9cATIBqUr-xcVfr_9NfQcVAY0a</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1812603341</pqid></control><display><type>article</type><title>Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique</title><source>MEDLINE</source><source>SpringerNature Journals</source><creator>Melich, George ; Pai, Ajit ; Balachandran, Banujan ; Marecik, Slawomir J. ; Prasad, Leela M. ; Park, John J.</creator><creatorcontrib>Melich, George ; Pai, Ajit ; Balachandran, Banujan ; Marecik, Slawomir J. ; Prasad, Leela M. ; Park, John J.</creatorcontrib><description>Introduction Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. Methods This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents—10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). Results The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9–3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Conclusions Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [ 1 ], there is no published account of bridging an enterocutaneous fistula with overlapping endoscopic stents through the fistula itself. This video serves as a proof of concept for temporizing enterocutaneous fistulas with endoscopic stenting.</description><identifier>ISSN: 0930-2794</identifier><identifier>EISSN: 1432-2218</identifier><identifier>DOI: 10.1007/s00464-015-4636-5</identifier><identifier>PMID: 27501730</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Abdominal Surgery ; Endoscopy ; Endoscopy - methods ; Gastroenterology ; Gynecology ; Hepatology ; Humans ; Ileostomy ; Intestinal Fistula - surgery ; Medicine ; Medicine &amp; Public Health ; Ostomy ; Postoperative Complications - surgery ; Proctology ; Stents ; Surgery ; Urinary Diversion ; Video</subject><ispartof>Surgical endoscopy, 2016-09, Vol.30 (9), p.4150-4151</ispartof><rights>Springer Science+Business Media New York 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-ca230ee999afd18a462c6da97986e713ea725807bf1fd1d68cc6a8b69458dc563</citedby><cites>FETCH-LOGICAL-c372t-ca230ee999afd18a462c6da97986e713ea725807bf1fd1d68cc6a8b69458dc563</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00464-015-4636-5$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00464-015-4636-5$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27501730$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Melich, George</creatorcontrib><creatorcontrib>Pai, Ajit</creatorcontrib><creatorcontrib>Balachandran, Banujan</creatorcontrib><creatorcontrib>Marecik, Slawomir J.</creatorcontrib><creatorcontrib>Prasad, Leela M.</creatorcontrib><creatorcontrib>Park, John J.</creatorcontrib><title>Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique</title><title>Surgical endoscopy</title><addtitle>Surg Endosc</addtitle><addtitle>Surg Endosc</addtitle><description>Introduction Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. Methods This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents—10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). Results The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9–3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Conclusions Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [ 1 ], there is no published account of bridging an enterocutaneous fistula with overlapping endoscopic stents through the fistula itself. This video serves as a proof of concept for temporizing enterocutaneous fistulas with endoscopic stenting.</description><subject>Abdominal Surgery</subject><subject>Endoscopy</subject><subject>Endoscopy - methods</subject><subject>Gastroenterology</subject><subject>Gynecology</subject><subject>Hepatology</subject><subject>Humans</subject><subject>Ileostomy</subject><subject>Intestinal Fistula - surgery</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Ostomy</subject><subject>Postoperative Complications - surgery</subject><subject>Proctology</subject><subject>Stents</subject><subject>Surgery</subject><subject>Urinary Diversion</subject><subject>Video</subject><issn>0930-2794</issn><issn>1432-2218</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNp1kElLBDEUhIMozrj8AC8S8OKlNVtnOcrgBoIXPYdMOq099CRjlsP8e6OtIoKnd6iv6hUFwAlGFxghcZkQYpw1CLcN45Q37Q6YY0ZJQwiWu2COFEUNEYrNwEFKK1Rxhdt9MCOiRVhQNAfP174LyYbNYKENPscwwtBD57OLwZZsvAslwX5IuYwGLrewK2aEg88lpZKs2-TBv8CUqwNmZ1_98FbcEdjrzZjc8dc9BM8310-Lu-bh8fZ-cfXQWCpIbqwhFDmnlDJ9h6VhnFjeGSWU5E5g6owgrURi2eOqd1xay41ccsVa2dmW00NwPuVuYqhvU9broXYax6m2xhITKbkQrKJnf9BVKNHXdp8UR5QyXCk8UTaGlKLr9SYOaxO3GiP9sbmeNtd1c_2xuW6r5_QruSzXrvtxfI9cATIBqUr-xcVfr_9NfQcVAY0a</recordid><startdate>20160901</startdate><enddate>20160901</enddate><creator>Melich, George</creator><creator>Pai, Ajit</creator><creator>Balachandran, Banujan</creator><creator>Marecik, Slawomir J.</creator><creator>Prasad, Leela M.</creator><creator>Park, John J.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20160901</creationdate><title>Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique</title><author>Melich, George ; Pai, Ajit ; Balachandran, Banujan ; Marecik, Slawomir J. ; Prasad, Leela M. ; Park, John J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-ca230ee999afd18a462c6da97986e713ea725807bf1fd1d68cc6a8b69458dc563</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Abdominal Surgery</topic><topic>Endoscopy</topic><topic>Endoscopy - methods</topic><topic>Gastroenterology</topic><topic>Gynecology</topic><topic>Hepatology</topic><topic>Humans</topic><topic>Ileostomy</topic><topic>Intestinal Fistula - surgery</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Ostomy</topic><topic>Postoperative Complications - surgery</topic><topic>Proctology</topic><topic>Stents</topic><topic>Surgery</topic><topic>Urinary Diversion</topic><topic>Video</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Melich, George</creatorcontrib><creatorcontrib>Pai, Ajit</creatorcontrib><creatorcontrib>Balachandran, Banujan</creatorcontrib><creatorcontrib>Marecik, Slawomir J.</creatorcontrib><creatorcontrib>Prasad, Leela M.</creatorcontrib><creatorcontrib>Park, John J.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Nursing &amp; Allied Health Source</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Surgical endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Melich, George</au><au>Pai, Ajit</au><au>Balachandran, Banujan</au><au>Marecik, Slawomir J.</au><au>Prasad, Leela M.</au><au>Park, John J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique</atitle><jtitle>Surgical endoscopy</jtitle><stitle>Surg Endosc</stitle><addtitle>Surg Endosc</addtitle><date>2016-09-01</date><risdate>2016</risdate><volume>30</volume><issue>9</issue><spage>4150</spage><epage>4151</epage><pages>4150-4151</pages><issn>0930-2794</issn><eissn>1432-2218</eissn><abstract>Introduction Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. Methods This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents—10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). Results The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9–3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Conclusions Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [ 1 ], there is no published account of bridging an enterocutaneous fistula with overlapping endoscopic stents through the fistula itself. This video serves as a proof of concept for temporizing enterocutaneous fistulas with endoscopic stenting.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>27501730</pmid><doi>10.1007/s00464-015-4636-5</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0930-2794
ispartof Surgical endoscopy, 2016-09, Vol.30 (9), p.4150-4151
issn 0930-2794
1432-2218
language eng
recordid cdi_proquest_miscellaneous_1812886774
source MEDLINE; SpringerNature Journals
subjects Abdominal Surgery
Endoscopy
Endoscopy - methods
Gastroenterology
Gynecology
Hepatology
Humans
Ileostomy
Intestinal Fistula - surgery
Medicine
Medicine & Public Health
Ostomy
Postoperative Complications - surgery
Proctology
Stents
Surgery
Urinary Diversion
Video
title Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T14%3A23%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endoscopic%20control%20of%20enterocutaneous%20fistula%20by%20dual%20intussuscepting%20stent%20technique&rft.jtitle=Surgical%20endoscopy&rft.au=Melich,%20George&rft.date=2016-09-01&rft.volume=30&rft.issue=9&rft.spage=4150&rft.epage=4151&rft.pages=4150-4151&rft.issn=0930-2794&rft.eissn=1432-2218&rft_id=info:doi/10.1007/s00464-015-4636-5&rft_dat=%3Cproquest_cross%3E1812886774%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1812603341&rft_id=info:pmid/27501730&rfr_iscdi=true