High performance liquid chromatography determination of dexamethasone in plasma to evaluate its systemic absorption following intra-space pterygomandibular injection of twin-mix (mixture of 2 % lignocaine with 1:200,000 epinephrine and 4 mg dexamethasone): randomized control trial

Purpose To determine systemic absorption of dexamethasone by detection of plasma concentration using high performance liquid chromatography following its administration along with local anesthetic agent as a mixture via pterygomandibular space. Methods A prospective randomized double-blind clinical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Oral and maxillofacial surgery 2016-09, Vol.20 (3), p.259-264
Hauptverfasser: Bhargava, Darpan, Deshpande, Ashwini, Thomas, Shaji, Sharma, Yogesh, Khare, Piush, Sahu, Sanjeev Kumar, Dubey, Suyash, Pandey, Ankit, Sreekumar, K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To determine systemic absorption of dexamethasone by detection of plasma concentration using high performance liquid chromatography following its administration along with local anesthetic agent as a mixture via pterygomandibular space. Methods A prospective randomized double-blind clinical study was undertaken to analyze the plasma concentration of dexamethasone after intra-space pterygomandibular injection along with local anesthesia. The study was performed as per split mouth model where the mandibular quadrant allocation was done on a random basis considering each of the 30 patients is included in the two study interventions (SS and CS). For the study site (SS) procedures, dexamethasone was administered as a mixture (2 % lignocaine with 1:200,000 epinephrine and 4 mg dexamethasone) intra-space. In the control site (CS) procedures, a regular standard inferior alveolar nerve block was administered, and dexamethasone was given as intramuscular injection. The plasma dexamethasone determination was done in venous blood 30- and 60-min post injection using high performance liquid chromatography (HPLC). The clinical parameters like pain; swelling; and mouth opening on the first, third, and seventh post-operative day were analyzed and compared. Results No significant difference was found in the clinical parameters assessed; comparative evaluation showed less swelling in the SS interventions. The plasma concentration of dexamethasone for the CS interventions was 226 ± 47 ng/ml at 30-min and 316 ± 81.6 ng/ml at 60-min post injection, and for SS, it was 221 ± 81.6 ng/ml at 30-min and 340 ± 105 ng/ml at 60-min post injection. On inter-site (CS and SS) comparison, no statistically significant difference was ascertained in dexamethasone plasma concentration at 30-min post injection ( P  = 0.77) and at 60-min post injection. ( P  = 0.32). Conclusion Intra-space (pterygomandibular space) administration of dexamethasone can achieve statistically similar plasma concentration of the drug as when the same dose is administered intramuscularly with demonstration of similar clinical effects.
ISSN:1865-1550
1865-1569
DOI:10.1007/s10006-016-0564-3