Multi-laboratory evaluation of SkinEthic HCE test method for testing serious eye damage/eye irritation using solid chemicals and overall performance of the test method with regard to solid and liquid chemicals testing

A prospective multicentre study of the reconstructed human corneal epithelial tissue-based in vitro test method (SkinEthic™ HCE) was conducted to evaluate its usefulness to identify chemicals as either not classified for serious eye damage/eye irritation (No Cat.) or as classified (Cat. 1/Cat. 2) wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Toxicology in vitro 2016-08, Vol.34, p.55-70
Hauptverfasser: Alépée, N., Adriaens, E., Grandidier, M.H., Meloni, M., Nardelli, L., Vinall, C.J., Toner, F., Roper, C.S., Van Rompay, A.R., Leblanc, V., Cotovio, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A prospective multicentre study of the reconstructed human corneal epithelial tissue-based in vitro test method (SkinEthic™ HCE) was conducted to evaluate its usefulness to identify chemicals as either not classified for serious eye damage/eye irritation (No Cat.) or as classified (Cat. 1/Cat. 2) within UN GHS. The aim of this study was to demonstrate the transferability and reproducibility of the SkinEthic™ HCE EITS protocol for solids and define its predictive capacity. Briefly, 60 chemicals were three times tested (double blinded) in 3 laboratories and 35 additional chemicals were tested three times in one laboratory. Good within laboratory reproducibility was achieved of at least 95% (57/60) and 96.8% (92/95) for the extended data set. Furthermore, the overall concordance between the laboratories was 96.7% (58/60). The accuracy of the SkinEthic™ HCE EITS for the extended dataset, based on bootstrap resampling, was 81.0% (95% CI: 78.9% to 83.2%) with a sensitivity of 90.5% (95% CI: 88.1% to 92.9%) and specificity of 73.6% (95% CI: 71.7% to 75.5%). Overall, 200 chemicals were tested (105 liquids (EITL protocol) and 95 solids (EITS protocol)) resulting in a sensitivity of 95.2%, specificity of 72.1% and accuracy of 83.7%, thereby meeting all acceptance criteria for predictive capacity. •SkinEthic™ HCE method has been developed for the Eye Irritation Testing of Solids.•A validation study has been conducted with three laboratories on 60 substances.•Good within- and between laboratory reproducibility was achieved of ≥95.0% and. 96.8%, respectively.•The accuracy was 81.0% with a sensitivity of 90.5% and specificity of 73.6% on 95 chemicals.•Overall, 200 chemicals were tested resulting in an accuracy of 83.7% meeting all acceptance criteria for predictive capacity.
ISSN:0887-2333
1879-3177
DOI:10.1016/j.tiv.2016.02.014