Fluorescent aptasensor for chloramphenicol detection using DIL-encapsulated liposome as nanotracer

A novel fluorescence aptasensor was successfully developed to respond to chloramphenicol (CAP) in food based on magnetic aptamer-liposome vesicle probe. In order to fabricate it, aptamer labeled on functionalized magnetic beads (MB) was firstly employed as capture adsorbent (MB-Apt), then SSB (singl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2016-07, Vol.81, p.454-459
Hauptverfasser: Miao, Yang-Bao, Ren, Hong-Xia, Gan, Ning, Cao, Yuting, Li, Tianhua, Chen, Yijin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A novel fluorescence aptasensor was successfully developed to respond to chloramphenicol (CAP) in food based on magnetic aptamer-liposome vesicle probe. In order to fabricate it, aptamer labeled on functionalized magnetic beads (MB) was firstly employed as capture adsorbent (MB-Apt), then SSB (single-stranded DNA binding protein) and DIL (1,1′-dioctadecyl-3,3,3′,3′-tetramethyl-indocarbocyanineperchlorate) coimmobilized liposomes (SSB/DIL-Lip) was employed as vesicle signal tracer. The composite vesicle probe is formed between SSB/DIL-Lip and MB-Apt based on SSB's specific recognition towards aptamer on vesicle signal tracer. Upon the vesicle probe solution reacted with CAP, the aptamer on the magnetic beads preferentially bounded with CAP, and then released SSB/DIL-Lip vesicle signal tracer in the supernatant after magnetic separation. The released tracer can emit fluorescence which was correspondence with the concentration of the analyte. At the optimum conditions, the aptasensor exhibited a good linear response for CAP detection in the range of 0.003–10nM with a detection limit of 1pM. Importantly, the methodology was further validated for analyzing CAP in fish samples with consistent results obtained by ELISA kit, thus providing a promising approach for quantitative monitoring of CAP and significant anti-interference ability in food safety. •A novel fluorescence aptasensor was successfully developed to detect chloramphenicol (CAP).•This probe can be fabricated though magnetic vesicle probes.•The vesicle probes can effective amplified signal.•This method for CAP detection in the fish samples agreed well with those from ELISA.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2016.03.034