The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance
As a key way of improving jet engine performance, a thermal tip clearance control system provides a robust means of manipulating the closure between the casing and the rotating blade tips, reducing undesirable tip leakage flows. This may be achieved using an impingement cooling scheme on the externa...
Gespeichert in:
Veröffentlicht in: | Journal of turbomachinery 2016-03, Vol.138 (3) |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | |
container_title | Journal of turbomachinery |
container_volume | 138 |
creator | Choi, Myeonggeun Dyrda, David M Gillespie, David R. H Tapanlis, Orpheas Lewis, Leo V |
description | As a key way of improving jet engine performance, a thermal tip clearance control system provides a robust means of manipulating the closure between the casing and the rotating blade tips, reducing undesirable tip leakage flows. This may be achieved using an impingement cooling scheme on the external casing. Such systems can be optimized to increase the contraction capability for a given casing cooling flow. Typically, this is achieved by changing the cooled area and local casing features, such as the external flanges or the external cooling geometry. This paper reports the effectiveness of a range of impingement cooling arrangements in typical engine casing closure system. The effects of jet-to-jet pitch, number of jets, and inline and staggered alignment of jets on an engine representative casing geometry are assessed through comparison of the convective heat transfer coefficient distributions as well as the thermal closure at the point of the casing liner attachment. The investigation is primarily numerical, however, a baseline case has been validated experimentally in tests using a transient liquid crystal technique. Steady numerical simulations using the realizable k–ε, k–ω SST, and EARSM turbulence models were conducted to understand the variation in the predicted local heat transfer coefficient distribution. A constant mass flow rate was used as a constraint at each engine condition, approximately corresponding to a constant feed pressure when the manifold exit area is constant. Sets of local heat transfer coefficient data generated using a consistent modeling approach were then used to create reduced order distributions of the local cooling. These were used in a thermomechanical model to predict the casing closure at engine representative operating conditions. |
doi_str_mv | 10.1115/1.4031907 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1808049870</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1808049870</sourcerecordid><originalsourceid>FETCH-LOGICAL-a282t-1098a5f0cb4cf4c25381a7d944abcfdaaeab2b2dd48bcfc14263af2266931fef3</originalsourceid><addsrcrecordid>eNotkDtPwzAUhS0EEqUwMLN4hCHFr7TOCFGBSpVAqEhs1k1yDamcONgpj39PonY6ulff-YZDyCVnM855estnikmescURmfBU6ERnjB2TCdM6S1Km3k_JWYxbxriUqZqQn80n0ld00NffSF8wWB8aaEuk3tLlb4-hBUdziHX7QVdNNwQ22PY0996Nv7sQ4PCLdCjTQTgYho5v--Dd6Ll3UCHd1B3NHUIY9efkxIKLeHHIKXl7WG7yp2T9_LjK79YJCC36hLNMQ2pZWajSqlKkUnNYVJlSUJS2AkAoRCGqSunhLrkScwlWiPk8k9yilVNyvfd2wX_tMPamqWOJzkGLfhcN10wzlekFG9CbPVoGH2NAa7pQNxD-DGdmHNdwcxh3YK_2LMQGzdbvxpmiUUppJuQ_Vgt2ug</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1808049870</pqid></control><display><type>article</type><title>The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance</title><source>ASME Digital Collection Journals</source><source>Alma/SFX Local Collection</source><creator>Choi, Myeonggeun ; Dyrda, David M ; Gillespie, David R. H ; Tapanlis, Orpheas ; Lewis, Leo V</creator><creatorcontrib>Choi, Myeonggeun ; Dyrda, David M ; Gillespie, David R. H ; Tapanlis, Orpheas ; Lewis, Leo V</creatorcontrib><description>As a key way of improving jet engine performance, a thermal tip clearance control system provides a robust means of manipulating the closure between the casing and the rotating blade tips, reducing undesirable tip leakage flows. This may be achieved using an impingement cooling scheme on the external casing. Such systems can be optimized to increase the contraction capability for a given casing cooling flow. Typically, this is achieved by changing the cooled area and local casing features, such as the external flanges or the external cooling geometry. This paper reports the effectiveness of a range of impingement cooling arrangements in typical engine casing closure system. The effects of jet-to-jet pitch, number of jets, and inline and staggered alignment of jets on an engine representative casing geometry are assessed through comparison of the convective heat transfer coefficient distributions as well as the thermal closure at the point of the casing liner attachment. The investigation is primarily numerical, however, a baseline case has been validated experimentally in tests using a transient liquid crystal technique. Steady numerical simulations using the realizable k–ε, k–ω SST, and EARSM turbulence models were conducted to understand the variation in the predicted local heat transfer coefficient distribution. A constant mass flow rate was used as a constraint at each engine condition, approximately corresponding to a constant feed pressure when the manifold exit area is constant. Sets of local heat transfer coefficient data generated using a consistent modeling approach were then used to create reduced order distributions of the local cooling. These were used in a thermomechanical model to predict the casing closure at engine representative operating conditions.</description><identifier>ISSN: 0889-504X</identifier><identifier>EISSN: 1528-8900</identifier><identifier>DOI: 10.1115/1.4031907</identifier><language>eng</language><publisher>ASME</publisher><subject>Closures ; Constants ; Cooling ; Cooling systems ; Engines ; Impingement ; Mathematical models ; Tip clearance</subject><ispartof>Journal of turbomachinery, 2016-03, Vol.138 (3)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a282t-1098a5f0cb4cf4c25381a7d944abcfdaaeab2b2dd48bcfc14263af2266931fef3</citedby><cites>FETCH-LOGICAL-a282t-1098a5f0cb4cf4c25381a7d944abcfdaaeab2b2dd48bcfc14263af2266931fef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,38520</link.rule.ids></links><search><creatorcontrib>Choi, Myeonggeun</creatorcontrib><creatorcontrib>Dyrda, David M</creatorcontrib><creatorcontrib>Gillespie, David R. H</creatorcontrib><creatorcontrib>Tapanlis, Orpheas</creatorcontrib><creatorcontrib>Lewis, Leo V</creatorcontrib><title>The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance</title><title>Journal of turbomachinery</title><addtitle>J. Turbomach</addtitle><description>As a key way of improving jet engine performance, a thermal tip clearance control system provides a robust means of manipulating the closure between the casing and the rotating blade tips, reducing undesirable tip leakage flows. This may be achieved using an impingement cooling scheme on the external casing. Such systems can be optimized to increase the contraction capability for a given casing cooling flow. Typically, this is achieved by changing the cooled area and local casing features, such as the external flanges or the external cooling geometry. This paper reports the effectiveness of a range of impingement cooling arrangements in typical engine casing closure system. The effects of jet-to-jet pitch, number of jets, and inline and staggered alignment of jets on an engine representative casing geometry are assessed through comparison of the convective heat transfer coefficient distributions as well as the thermal closure at the point of the casing liner attachment. The investigation is primarily numerical, however, a baseline case has been validated experimentally in tests using a transient liquid crystal technique. Steady numerical simulations using the realizable k–ε, k–ω SST, and EARSM turbulence models were conducted to understand the variation in the predicted local heat transfer coefficient distribution. A constant mass flow rate was used as a constraint at each engine condition, approximately corresponding to a constant feed pressure when the manifold exit area is constant. Sets of local heat transfer coefficient data generated using a consistent modeling approach were then used to create reduced order distributions of the local cooling. These were used in a thermomechanical model to predict the casing closure at engine representative operating conditions.</description><subject>Closures</subject><subject>Constants</subject><subject>Cooling</subject><subject>Cooling systems</subject><subject>Engines</subject><subject>Impingement</subject><subject>Mathematical models</subject><subject>Tip clearance</subject><issn>0889-504X</issn><issn>1528-8900</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNotkDtPwzAUhS0EEqUwMLN4hCHFr7TOCFGBSpVAqEhs1k1yDamcONgpj39PonY6ulff-YZDyCVnM855estnikmescURmfBU6ERnjB2TCdM6S1Km3k_JWYxbxriUqZqQn80n0ld00NffSF8wWB8aaEuk3tLlb4-hBUdziHX7QVdNNwQ22PY0996Nv7sQ4PCLdCjTQTgYho5v--Dd6Ll3UCHd1B3NHUIY9efkxIKLeHHIKXl7WG7yp2T9_LjK79YJCC36hLNMQ2pZWajSqlKkUnNYVJlSUJS2AkAoRCGqSunhLrkScwlWiPk8k9yilVNyvfd2wX_tMPamqWOJzkGLfhcN10wzlekFG9CbPVoGH2NAa7pQNxD-DGdmHNdwcxh3YK_2LMQGzdbvxpmiUUppJuQ_Vgt2ug</recordid><startdate>20160301</startdate><enddate>20160301</enddate><creator>Choi, Myeonggeun</creator><creator>Dyrda, David M</creator><creator>Gillespie, David R. H</creator><creator>Tapanlis, Orpheas</creator><creator>Lewis, Leo V</creator><general>ASME</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20160301</creationdate><title>The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance</title><author>Choi, Myeonggeun ; Dyrda, David M ; Gillespie, David R. H ; Tapanlis, Orpheas ; Lewis, Leo V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a282t-1098a5f0cb4cf4c25381a7d944abcfdaaeab2b2dd48bcfc14263af2266931fef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Closures</topic><topic>Constants</topic><topic>Cooling</topic><topic>Cooling systems</topic><topic>Engines</topic><topic>Impingement</topic><topic>Mathematical models</topic><topic>Tip clearance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, Myeonggeun</creatorcontrib><creatorcontrib>Dyrda, David M</creatorcontrib><creatorcontrib>Gillespie, David R. H</creatorcontrib><creatorcontrib>Tapanlis, Orpheas</creatorcontrib><creatorcontrib>Lewis, Leo V</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of turbomachinery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, Myeonggeun</au><au>Dyrda, David M</au><au>Gillespie, David R. H</au><au>Tapanlis, Orpheas</au><au>Lewis, Leo V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance</atitle><jtitle>Journal of turbomachinery</jtitle><stitle>J. Turbomach</stitle><date>2016-03-01</date><risdate>2016</risdate><volume>138</volume><issue>3</issue><issn>0889-504X</issn><eissn>1528-8900</eissn><abstract>As a key way of improving jet engine performance, a thermal tip clearance control system provides a robust means of manipulating the closure between the casing and the rotating blade tips, reducing undesirable tip leakage flows. This may be achieved using an impingement cooling scheme on the external casing. Such systems can be optimized to increase the contraction capability for a given casing cooling flow. Typically, this is achieved by changing the cooled area and local casing features, such as the external flanges or the external cooling geometry. This paper reports the effectiveness of a range of impingement cooling arrangements in typical engine casing closure system. The effects of jet-to-jet pitch, number of jets, and inline and staggered alignment of jets on an engine representative casing geometry are assessed through comparison of the convective heat transfer coefficient distributions as well as the thermal closure at the point of the casing liner attachment. The investigation is primarily numerical, however, a baseline case has been validated experimentally in tests using a transient liquid crystal technique. Steady numerical simulations using the realizable k–ε, k–ω SST, and EARSM turbulence models were conducted to understand the variation in the predicted local heat transfer coefficient distribution. A constant mass flow rate was used as a constraint at each engine condition, approximately corresponding to a constant feed pressure when the manifold exit area is constant. Sets of local heat transfer coefficient data generated using a consistent modeling approach were then used to create reduced order distributions of the local cooling. These were used in a thermomechanical model to predict the casing closure at engine representative operating conditions.</abstract><pub>ASME</pub><doi>10.1115/1.4031907</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0889-504X |
ispartof | Journal of turbomachinery, 2016-03, Vol.138 (3) |
issn | 0889-504X 1528-8900 |
language | eng |
recordid | cdi_proquest_miscellaneous_1808049870 |
source | ASME Digital Collection Journals; Alma/SFX Local Collection |
subjects | Closures Constants Cooling Cooling systems Engines Impingement Mathematical models Tip clearance |
title | The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T13%3A36%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Relative%20Performance%20of%20External%20Casing%20Impingement%20Cooling%20Arrangements%20for%20Thermal%20Control%20of%20Blade%20Tip%20Clearance&rft.jtitle=Journal%20of%20turbomachinery&rft.au=Choi,%20Myeonggeun&rft.date=2016-03-01&rft.volume=138&rft.issue=3&rft.issn=0889-504X&rft.eissn=1528-8900&rft_id=info:doi/10.1115/1.4031907&rft_dat=%3Cproquest_cross%3E1808049870%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1808049870&rft_id=info:pmid/&rfr_iscdi=true |