Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine

Aptasensing of small molecules remains a challenge as detection often requires the use of labels or signal amplification methodologies, resulting in both difficult-to-prepare sensor platforms and multistep, complex assays. Furthermore, many aptasensors rely on the binding mechanism or structural cha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 2016-03, Vol.88 (6), p.3098-3106
Hauptverfasser: Neves, Miguel A. D, Blaszykowski, Christophe, Thompson, Michael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3106
container_issue 6
container_start_page 3098
container_title Analytical chemistry (Washington)
container_volume 88
creator Neves, Miguel A. D
Blaszykowski, Christophe
Thompson, Michael
description Aptasensing of small molecules remains a challenge as detection often requires the use of labels or signal amplification methodologies, resulting in both difficult-to-prepare sensor platforms and multistep, complex assays. Furthermore, many aptasensors rely on the binding mechanism or structural changes associated with target capture by the aptameric probe, resulting in a detection scheme customized to each aptamer. It is in this context that we report herein a sensitive cocaine aptasensor that offers both real-time and label-free measurement capabilities. Detection relies on the electromagnetic piezoelectric acoustic sensor (EMPAS) platform. The sensing interface consists of a S-(11-trichlorosilyl-undecanyl)­benzenethiosulfonate (BTS) adlayer-coated quartz disc onto which a structure-switching cocaine aptamer (MN6) is immobilized, completing the preparation of the MN6 cocaine aptasensor (M6CA). The EMPAS system has recently been employed as the foundation of a cocaine aptasensor based on a structurally rigid cocaine aptamer variant (MN4), an aptasensor referred to by analogy as M4CA. M6CA represents a significant increase in terms of analytical performance, compared to not only M4CA but also other cocaine aptamer-based sensors that do not rely on signal amplification, producing an apparent K d of 27 ± 6 μM and a 0.3 μM detection limit. Remarkably, the latter is in the range of that achieved by cocaine aptasensors relying on signal amplification. Furthermore, M6CA proved to be capable not only of regaining its cocaine-binding ability via simple buffer flow over the sensing interface (i.e., without the necessity to implement an additional regeneration step, such as in the case of M4CA), but also of detecting cocaine in a multicomponent matrix possessing potentially assay-interfering species. Finally, through observation of the distinct shape of its response profiles to cocaine injection, demonstration was made that the EMPAS system in practice offers the possibility to distinguish between the binding mechanisms of structure-switching (MN6) vs rigid (MN4) aptameric probes, an ability that could allow the EMPAS to provide a more universal aptasensing platform than what is ordinarily observed in the literature.
doi_str_mv 10.1021/acs.analchem.5b04010
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1808045931</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1808045931</sourcerecordid><originalsourceid>FETCH-LOGICAL-a409t-9e92b9a67928880ea52ecb71e307f877b25c76f375d69ddd9b09308e6cbdbe873</originalsourceid><addsrcrecordid>eNqFkU1P4zAQhq0Vq6Ww-w8QssSFS8rY-bB9ROVTdMWh9Bw5zoQY5aPYjlD59aS07Eoc4DSX531nNA8hRwymDDg708ZPdacbU2M7TQtIgMEPMmEphyiTku-RCQDEERcA--TA-ycAxoBlv8g-z6RgMeMTUi2Dbeyr7R6ppne4pueroFt0dBHcYMLgMFq82GDqDfEXTa0761ta9Y6GGumyCU7X9rGmVw6fB-zMml5gQBNs39G-orPeaNvhb_Kz0o3HP7t5SJZXlw-zm2h-f307O59HOgEVIoWKF0pnQnEpJaBOOZpCMIxBVFKIgqdGZFUs0jJTZVmqAlQMEjNTlAVKER-S023vyvXjOT7krfUGm0Z32A8-ZxIkJKmK2feoELEExRIY0ZNP6FM_uPH375QU47vFhkq2lHG99w6rfOVsq906Z5BvlOWjsvxDWb5TNsaOd-VD0WL5L_ThaARgC2zi_xd_1fkGAqulAg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1778768870</pqid></control><display><type>article</type><title>Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine</title><source>ACS Publications</source><source>MEDLINE</source><creator>Neves, Miguel A. D ; Blaszykowski, Christophe ; Thompson, Michael</creator><creatorcontrib>Neves, Miguel A. D ; Blaszykowski, Christophe ; Thompson, Michael</creatorcontrib><description>Aptasensing of small molecules remains a challenge as detection often requires the use of labels or signal amplification methodologies, resulting in both difficult-to-prepare sensor platforms and multistep, complex assays. Furthermore, many aptasensors rely on the binding mechanism or structural changes associated with target capture by the aptameric probe, resulting in a detection scheme customized to each aptamer. It is in this context that we report herein a sensitive cocaine aptasensor that offers both real-time and label-free measurement capabilities. Detection relies on the electromagnetic piezoelectric acoustic sensor (EMPAS) platform. The sensing interface consists of a S-(11-trichlorosilyl-undecanyl)­benzenethiosulfonate (BTS) adlayer-coated quartz disc onto which a structure-switching cocaine aptamer (MN6) is immobilized, completing the preparation of the MN6 cocaine aptasensor (M6CA). The EMPAS system has recently been employed as the foundation of a cocaine aptasensor based on a structurally rigid cocaine aptamer variant (MN4), an aptasensor referred to by analogy as M4CA. M6CA represents a significant increase in terms of analytical performance, compared to not only M4CA but also other cocaine aptamer-based sensors that do not rely on signal amplification, producing an apparent K d of 27 ± 6 μM and a 0.3 μM detection limit. Remarkably, the latter is in the range of that achieved by cocaine aptasensors relying on signal amplification. Furthermore, M6CA proved to be capable not only of regaining its cocaine-binding ability via simple buffer flow over the sensing interface (i.e., without the necessity to implement an additional regeneration step, such as in the case of M4CA), but also of detecting cocaine in a multicomponent matrix possessing potentially assay-interfering species. Finally, through observation of the distinct shape of its response profiles to cocaine injection, demonstration was made that the EMPAS system in practice offers the possibility to distinguish between the binding mechanisms of structure-switching (MN6) vs rigid (MN4) aptameric probes, an ability that could allow the EMPAS to provide a more universal aptasensing platform than what is ordinarily observed in the literature.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/acs.analchem.5b04010</identifier><identifier>PMID: 26871312</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Amplification ; Analytical chemistry ; Aptamers, Nucleotide - chemistry ; Assaying ; Binding ; Biosensing Techniques ; Cocaine ; Cocaine - analysis ; Detection ; Electromagnetics ; Limit of Detection ; Molecules ; Narcotics ; Platforms ; Sensors</subject><ispartof>Analytical chemistry (Washington), 2016-03, Vol.88 (6), p.3098-3106</ispartof><rights>Copyright © 2016 American Chemical Society</rights><rights>Copyright American Chemical Society Mar 15, 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a409t-9e92b9a67928880ea52ecb71e307f877b25c76f375d69ddd9b09308e6cbdbe873</citedby><cites>FETCH-LOGICAL-a409t-9e92b9a67928880ea52ecb71e307f877b25c76f375d69ddd9b09308e6cbdbe873</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acs.analchem.5b04010$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acs.analchem.5b04010$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26871312$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Neves, Miguel A. D</creatorcontrib><creatorcontrib>Blaszykowski, Christophe</creatorcontrib><creatorcontrib>Thompson, Michael</creatorcontrib><title>Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Aptasensing of small molecules remains a challenge as detection often requires the use of labels or signal amplification methodologies, resulting in both difficult-to-prepare sensor platforms and multistep, complex assays. Furthermore, many aptasensors rely on the binding mechanism or structural changes associated with target capture by the aptameric probe, resulting in a detection scheme customized to each aptamer. It is in this context that we report herein a sensitive cocaine aptasensor that offers both real-time and label-free measurement capabilities. Detection relies on the electromagnetic piezoelectric acoustic sensor (EMPAS) platform. The sensing interface consists of a S-(11-trichlorosilyl-undecanyl)­benzenethiosulfonate (BTS) adlayer-coated quartz disc onto which a structure-switching cocaine aptamer (MN6) is immobilized, completing the preparation of the MN6 cocaine aptasensor (M6CA). The EMPAS system has recently been employed as the foundation of a cocaine aptasensor based on a structurally rigid cocaine aptamer variant (MN4), an aptasensor referred to by analogy as M4CA. M6CA represents a significant increase in terms of analytical performance, compared to not only M4CA but also other cocaine aptamer-based sensors that do not rely on signal amplification, producing an apparent K d of 27 ± 6 μM and a 0.3 μM detection limit. Remarkably, the latter is in the range of that achieved by cocaine aptasensors relying on signal amplification. Furthermore, M6CA proved to be capable not only of regaining its cocaine-binding ability via simple buffer flow over the sensing interface (i.e., without the necessity to implement an additional regeneration step, such as in the case of M4CA), but also of detecting cocaine in a multicomponent matrix possessing potentially assay-interfering species. Finally, through observation of the distinct shape of its response profiles to cocaine injection, demonstration was made that the EMPAS system in practice offers the possibility to distinguish between the binding mechanisms of structure-switching (MN6) vs rigid (MN4) aptameric probes, an ability that could allow the EMPAS to provide a more universal aptasensing platform than what is ordinarily observed in the literature.</description><subject>Amplification</subject><subject>Analytical chemistry</subject><subject>Aptamers, Nucleotide - chemistry</subject><subject>Assaying</subject><subject>Binding</subject><subject>Biosensing Techniques</subject><subject>Cocaine</subject><subject>Cocaine - analysis</subject><subject>Detection</subject><subject>Electromagnetics</subject><subject>Limit of Detection</subject><subject>Molecules</subject><subject>Narcotics</subject><subject>Platforms</subject><subject>Sensors</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1P4zAQhq0Vq6Ww-w8QssSFS8rY-bB9ROVTdMWh9Bw5zoQY5aPYjlD59aS07Eoc4DSX531nNA8hRwymDDg708ZPdacbU2M7TQtIgMEPMmEphyiTku-RCQDEERcA--TA-ycAxoBlv8g-z6RgMeMTUi2Dbeyr7R6ppne4pueroFt0dBHcYMLgMFq82GDqDfEXTa0761ta9Y6GGumyCU7X9rGmVw6fB-zMml5gQBNs39G-orPeaNvhb_Kz0o3HP7t5SJZXlw-zm2h-f307O59HOgEVIoWKF0pnQnEpJaBOOZpCMIxBVFKIgqdGZFUs0jJTZVmqAlQMEjNTlAVKER-S023vyvXjOT7krfUGm0Z32A8-ZxIkJKmK2feoELEExRIY0ZNP6FM_uPH375QU47vFhkq2lHG99w6rfOVsq906Z5BvlOWjsvxDWb5TNsaOd-VD0WL5L_ThaARgC2zi_xd_1fkGAqulAg</recordid><startdate>20160315</startdate><enddate>20160315</enddate><creator>Neves, Miguel A. D</creator><creator>Blaszykowski, Christophe</creator><creator>Thompson, Michael</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20160315</creationdate><title>Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine</title><author>Neves, Miguel A. D ; Blaszykowski, Christophe ; Thompson, Michael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a409t-9e92b9a67928880ea52ecb71e307f877b25c76f375d69ddd9b09308e6cbdbe873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Amplification</topic><topic>Analytical chemistry</topic><topic>Aptamers, Nucleotide - chemistry</topic><topic>Assaying</topic><topic>Binding</topic><topic>Biosensing Techniques</topic><topic>Cocaine</topic><topic>Cocaine - analysis</topic><topic>Detection</topic><topic>Electromagnetics</topic><topic>Limit of Detection</topic><topic>Molecules</topic><topic>Narcotics</topic><topic>Platforms</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Neves, Miguel A. D</creatorcontrib><creatorcontrib>Blaszykowski, Christophe</creatorcontrib><creatorcontrib>Thompson, Michael</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Neves, Miguel A. D</au><au>Blaszykowski, Christophe</au><au>Thompson, Michael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2016-03-15</date><risdate>2016</risdate><volume>88</volume><issue>6</issue><spage>3098</spage><epage>3106</epage><pages>3098-3106</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>Aptasensing of small molecules remains a challenge as detection often requires the use of labels or signal amplification methodologies, resulting in both difficult-to-prepare sensor platforms and multistep, complex assays. Furthermore, many aptasensors rely on the binding mechanism or structural changes associated with target capture by the aptameric probe, resulting in a detection scheme customized to each aptamer. It is in this context that we report herein a sensitive cocaine aptasensor that offers both real-time and label-free measurement capabilities. Detection relies on the electromagnetic piezoelectric acoustic sensor (EMPAS) platform. The sensing interface consists of a S-(11-trichlorosilyl-undecanyl)­benzenethiosulfonate (BTS) adlayer-coated quartz disc onto which a structure-switching cocaine aptamer (MN6) is immobilized, completing the preparation of the MN6 cocaine aptasensor (M6CA). The EMPAS system has recently been employed as the foundation of a cocaine aptasensor based on a structurally rigid cocaine aptamer variant (MN4), an aptasensor referred to by analogy as M4CA. M6CA represents a significant increase in terms of analytical performance, compared to not only M4CA but also other cocaine aptamer-based sensors that do not rely on signal amplification, producing an apparent K d of 27 ± 6 μM and a 0.3 μM detection limit. Remarkably, the latter is in the range of that achieved by cocaine aptasensors relying on signal amplification. Furthermore, M6CA proved to be capable not only of regaining its cocaine-binding ability via simple buffer flow over the sensing interface (i.e., without the necessity to implement an additional regeneration step, such as in the case of M4CA), but also of detecting cocaine in a multicomponent matrix possessing potentially assay-interfering species. Finally, through observation of the distinct shape of its response profiles to cocaine injection, demonstration was made that the EMPAS system in practice offers the possibility to distinguish between the binding mechanisms of structure-switching (MN6) vs rigid (MN4) aptameric probes, an ability that could allow the EMPAS to provide a more universal aptasensing platform than what is ordinarily observed in the literature.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>26871312</pmid><doi>10.1021/acs.analchem.5b04010</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2016-03, Vol.88 (6), p.3098-3106
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_1808045931
source ACS Publications; MEDLINE
subjects Amplification
Analytical chemistry
Aptamers, Nucleotide - chemistry
Assaying
Binding
Biosensing Techniques
Cocaine
Cocaine - analysis
Detection
Electromagnetics
Limit of Detection
Molecules
Narcotics
Platforms
Sensors
title Utilizing a Key Aptamer Structure-Switching Mechanism for the Ultrahigh Frequency Detection of Cocaine
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-16T03%3A28%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Utilizing%20a%20Key%20Aptamer%20Structure-Switching%20Mechanism%20for%20the%20Ultrahigh%20Frequency%20Detection%20of%20Cocaine&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Neves,%20Miguel%20A.%20D&rft.date=2016-03-15&rft.volume=88&rft.issue=6&rft.spage=3098&rft.epage=3106&rft.pages=3098-3106&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/acs.analchem.5b04010&rft_dat=%3Cproquest_cross%3E1808045931%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1778768870&rft_id=info:pmid/26871312&rfr_iscdi=true