Tensile Strength and Oxide Analysis of Carbon Steel in Concrete Exposed in Atmospheric Environment for 53 Years

The tensile strength of a corroded rebar in a 53-year-old concrete structure was studied. The microstructure of the metallic substrate, the fracture surface, and the corrosion product layers were investigated. Metallographic observation results showed that the carbon steel was constituted of ferrite...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Wuhan University of Technology. Materials science edition 2015-08, Vol.30 (4), p.790-795
Hauptverfasser: Feng, Xingguo, Lu, Xiangyu, Zuo, Yu, Chen, Da, Su, Xiaodong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The tensile strength of a corroded rebar in a 53-year-old concrete structure was studied. The microstructure of the metallic substrate, the fracture surface, and the corrosion product layers were investigated. Metallographic observation results showed that the carbon steel was constituted of ferrite and some pearlite. The tensile test results indicated that the corroded rebar presented low strength and elongation. In addition, the fracture surface of the rebar in the tensile test displayed dimple fracture behavior. The Raman spectroscopy results indicated that corrosion products at the general corrosion zone were obviously different from those at the localized corrosion zone. The rust layer at the general corrosion zone was composed of goethite (α-FeOOH), magnetite (Fe304), and hematite (α-Fe203), while that of the pitting zone was made of feroxyhyte (δ-FeOOH), goethite (α-FeOOH), and hematite (α-Fe203). However, the general tendencies that the corrosion products were constituted of a mix of oxides and hydroxides, the oxides mainly existed in the internal part and the hydroxides more presented in the external layer were observed.
ISSN:1000-2413
1993-0437
DOI:10.1007/s11595-015-1229-z