Multivariate optimization by statistical methods of ultra high performance liquid chromatography conditions for the separation of 17 capsaicinoids

In this work, multivariate optimization by statistical methods (Derringer and Suich optimization) was proposed in order to find the optimum conditions of an Ultra High Performance Liquid Chromatograph with Diode Array Detection (UHPLCDAD) for the separation of seventeen capsaicinoids (natural and sy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2016-01, Vol.8 (7), p.1659-1666
Hauptverfasser: Coutinho, Janclei Pereira, Barbero, Gerardo Fernández, Godoy, Helena Teixeira, Palma, Miguel, Barroso, Carmelo García
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this work, multivariate optimization by statistical methods (Derringer and Suich optimization) was proposed in order to find the optimum conditions of an Ultra High Performance Liquid Chromatograph with Diode Array Detection (UHPLCDAD) for the separation of seventeen capsaicinoids (natural and synthetic). Capsaicinoids were analyzed at 280 nm. The variables optimized were the mobile phase (water (0.1% acetic acid as solvent A) and acetonitrile (0.1% as solvent B)), gradient time and flow rate. Two columns with different lengths (50 and 100 mm) were used for the chromatographic separation. The two columns used properly separated fifteen of the seventeen capsaicinoids, but capsaicin (C) and N -(4-hydroxy-3-methoxybenzyl) nonanamide (N9C) could not be separated. However the 50 mm column length showed a better chromatographic separation with a shorter run time and smaller peak widths. These results provided better values of limits of detection and quantification for the 50 mm column length. The better conditions of separation with the 50 mm column length were established with: initial mobile phase with 0% of solvent B; 8.12 minutes of the linear gradient time to reach 100% of solvent B; a flow rate of 0.8 mL min −1 . A validation of the method has been done with good values of repeatability (RSD < 1.92) and intermediate precision (RSD < 3.92). The developed method has been applied to real food samples. Capsaicin and dihydrocapsaicin have been identified and quantified in all of the spicy foods analyzed. Two new methods for the separation of capsaicin, dihydrocapsaicin and fifteen other synthetic capsaicinoids with properties similar to those of natural capsaicinoids with different chain lengths have been developed.
ISSN:1759-9660
1759-9679
DOI:10.1039/c5ay03211c