Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion
In this work, bromine and iodine determination in milk powder for adult and infant nutrition was performed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion by microwave-induced combustion (MIC). Contrarily...
Gespeichert in:
Veröffentlicht in: | Spectrochimica acta. Part B: Atomic spectroscopy 2015-05, Vol.107, p.86-92 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 92 |
---|---|
container_issue | |
container_start_page | 86 |
container_title | Spectrochimica acta. Part B: Atomic spectroscopy |
container_volume | 107 |
creator | Picoloto, Rochele S. Doneda, Morgana Flores, Eder L.M. Mesko, Marcia F. Flores, Erico M.M. Mello, Paola A. |
description | In this work, bromine and iodine determination in milk powder for adult and infant nutrition was performed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion by microwave-induced combustion (MIC). Contrarily to previous works using MIC, a higher sample mass was digested (700 mg). Water and ammonium hydroxide (10 to 100mmolL−1) were investigated as absorbing solutions and accurate results were achieved using a 25mmolL−1 NH4OH solution. Moreover, the high stability of analytes after digestion (up to 30 days) using this solution was observed. The accuracy of the proposed MIC method was evaluated using certified and reference materials of milk powder (NIST 1549 and NIST 8435). No statistical difference was observed between results obtained by MIC-ICP-MS and reference values. Results for samples were also compared with those obtained by ICP-OES and no statistical difference was observed. Microwave-assisted alkaline extraction (MW-AE) was also evaluated for milk powder using NH4OH and tetramethylammonium hydroxide solutions. Solutions obtained after digestion by MIC (whole milk powder) presented low carbon content in digests ( |
doi_str_mv | 10.1016/j.sab.2015.02.007 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1800435320</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0584854715000555</els_id><sourcerecordid>1800435320</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-ff208bb3f6111b614eda968f2ea5fe2f1e7191ef5f840abb02efe96095c293d83</originalsourceid><addsrcrecordid>eNqFkc1u1TAQhS0EEpfSB-jOSzYJYzvOj1ihCgpSJRbA2rLjcfElsS920qrv1Iesc8MaVh5L3znzcwi5YlAzYO37Y521qTkwWQOvAboX5MD6TlRCtvIlOYDsm6qXTfeavMn5CABccnkgT9_9vE6LDhjXTC0umGYf9OJjoNFRk2L5ItXBUh_tVvpAZz_9pqf4YDFRFxPVtljsTHA6LDSsS_JnD_NIT5POs6ZGZ7R0wfFX8H9WzFS70oxaf4f5jK7Zh7viPab4oO-x8sGuY5GMcTbrGXlLXjk9Zbz8-16Qn58__bj-Ut1-u_l6_fG2GkUrlso5Dr0xwrWMMdOyBq0e2t5x1NIhdww7NjB00vUNaGOAo8OhhUGOfBC2Fxfk3e57SnEbdVGzzyNO034mxXqARkjB4f9oJ3jP23bYULajZcGcEzp1Sn7W6VExUFuI6qhKiGoLUQFXJcSi-bBrsKx77zGpPHoM5Sw-4bgoG_0_1M8qg6nY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1732826690</pqid></control><display><type>article</type><title>Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion</title><source>Elsevier ScienceDirect Journals</source><creator>Picoloto, Rochele S. ; Doneda, Morgana ; Flores, Eder L.M. ; Mesko, Marcia F. ; Flores, Erico M.M. ; Mello, Paola A.</creator><creatorcontrib>Picoloto, Rochele S. ; Doneda, Morgana ; Flores, Eder L.M. ; Mesko, Marcia F. ; Flores, Erico M.M. ; Mello, Paola A.</creatorcontrib><description>In this work, bromine and iodine determination in milk powder for adult and infant nutrition was performed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion by microwave-induced combustion (MIC). Contrarily to previous works using MIC, a higher sample mass was digested (700 mg). Water and ammonium hydroxide (10 to 100mmolL−1) were investigated as absorbing solutions and accurate results were achieved using a 25mmolL−1 NH4OH solution. Moreover, the high stability of analytes after digestion (up to 30 days) using this solution was observed. The accuracy of the proposed MIC method was evaluated using certified and reference materials of milk powder (NIST 1549 and NIST 8435). No statistical difference was observed between results obtained by MIC-ICP-MS and reference values. Results for samples were also compared with those obtained by ICP-OES and no statistical difference was observed. Microwave-assisted alkaline extraction (MW-AE) was also evaluated for milk powder using NH4OH and tetramethylammonium hydroxide solutions. Solutions obtained after digestion by MIC (whole milk powder) presented low carbon content in digests (<25mgL−1) while solutions obtained after alkaline extraction presented up to 10,000mgL−1 of C. MIC method was preferable in view of the possibility of obtaining solutions with low carbon content even using a relatively high sample mass (up to 700mg) avoiding additional dilution prior to ICP-MS analysis, thus allowing better detection limits. Limits of detection obtained by MIC-ICP-MS were 0.007 and 0.003μgg−1 for Br and I, respectively, while for MW-AE were 0.1 and 0.05μgg−1 respectively for Br and I. Among the main advantages of the proposed method are the use of diluted alkaline solutions that is in agreement with green analytical chemistry recommendations, the high stability of analytes in solution and the suitability of digests for analysis by ICP-MS and also ICP-OES, minimizing memory effects and being advantageous for routine analysis.
•Microwave-induced combustion (MIC) was feasible for further Br and I determination by ICP-MS and ICP-OES.•MIC allowed a high milk powder mass digestion (700mg).•Only diluted solutions were necessary for analyte absorption.•Digests by MIC presented very low carbon content, avoiding interferences during Br and I determination.•A high throughput was obtained (8 samples digested in less than 25min including cooling step).</description><identifier>ISSN: 0584-8547</identifier><identifier>EISSN: 1873-3565</identifier><identifier>DOI: 10.1016/j.sab.2015.02.007</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Bromine determination ; Combustion ; Digestion ; ICP-MS ; Infants ; Iodine determination ; Microwave-induced combustion ; Milk ; Milk powder ; Nutrition ; Samples ; Statistical analysis ; Statistical methods</subject><ispartof>Spectrochimica acta. Part B: Atomic spectroscopy, 2015-05, Vol.107, p.86-92</ispartof><rights>2015 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-ff208bb3f6111b614eda968f2ea5fe2f1e7191ef5f840abb02efe96095c293d83</citedby><cites>FETCH-LOGICAL-c363t-ff208bb3f6111b614eda968f2ea5fe2f1e7191ef5f840abb02efe96095c293d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0584854715000555$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids></links><search><creatorcontrib>Picoloto, Rochele S.</creatorcontrib><creatorcontrib>Doneda, Morgana</creatorcontrib><creatorcontrib>Flores, Eder L.M.</creatorcontrib><creatorcontrib>Mesko, Marcia F.</creatorcontrib><creatorcontrib>Flores, Erico M.M.</creatorcontrib><creatorcontrib>Mello, Paola A.</creatorcontrib><title>Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion</title><title>Spectrochimica acta. Part B: Atomic spectroscopy</title><description>In this work, bromine and iodine determination in milk powder for adult and infant nutrition was performed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion by microwave-induced combustion (MIC). Contrarily to previous works using MIC, a higher sample mass was digested (700 mg). Water and ammonium hydroxide (10 to 100mmolL−1) were investigated as absorbing solutions and accurate results were achieved using a 25mmolL−1 NH4OH solution. Moreover, the high stability of analytes after digestion (up to 30 days) using this solution was observed. The accuracy of the proposed MIC method was evaluated using certified and reference materials of milk powder (NIST 1549 and NIST 8435). No statistical difference was observed between results obtained by MIC-ICP-MS and reference values. Results for samples were also compared with those obtained by ICP-OES and no statistical difference was observed. Microwave-assisted alkaline extraction (MW-AE) was also evaluated for milk powder using NH4OH and tetramethylammonium hydroxide solutions. Solutions obtained after digestion by MIC (whole milk powder) presented low carbon content in digests (<25mgL−1) while solutions obtained after alkaline extraction presented up to 10,000mgL−1 of C. MIC method was preferable in view of the possibility of obtaining solutions with low carbon content even using a relatively high sample mass (up to 700mg) avoiding additional dilution prior to ICP-MS analysis, thus allowing better detection limits. Limits of detection obtained by MIC-ICP-MS were 0.007 and 0.003μgg−1 for Br and I, respectively, while for MW-AE were 0.1 and 0.05μgg−1 respectively for Br and I. Among the main advantages of the proposed method are the use of diluted alkaline solutions that is in agreement with green analytical chemistry recommendations, the high stability of analytes in solution and the suitability of digests for analysis by ICP-MS and also ICP-OES, minimizing memory effects and being advantageous for routine analysis.
•Microwave-induced combustion (MIC) was feasible for further Br and I determination by ICP-MS and ICP-OES.•MIC allowed a high milk powder mass digestion (700mg).•Only diluted solutions were necessary for analyte absorption.•Digests by MIC presented very low carbon content, avoiding interferences during Br and I determination.•A high throughput was obtained (8 samples digested in less than 25min including cooling step).</description><subject>Bromine determination</subject><subject>Combustion</subject><subject>Digestion</subject><subject>ICP-MS</subject><subject>Infants</subject><subject>Iodine determination</subject><subject>Microwave-induced combustion</subject><subject>Milk</subject><subject>Milk powder</subject><subject>Nutrition</subject><subject>Samples</subject><subject>Statistical analysis</subject><subject>Statistical methods</subject><issn>0584-8547</issn><issn>1873-3565</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u1TAQhS0EEpfSB-jOSzYJYzvOj1ihCgpSJRbA2rLjcfElsS920qrv1Iesc8MaVh5L3znzcwi5YlAzYO37Y521qTkwWQOvAboX5MD6TlRCtvIlOYDsm6qXTfeavMn5CABccnkgT9_9vE6LDhjXTC0umGYf9OJjoNFRk2L5ItXBUh_tVvpAZz_9pqf4YDFRFxPVtljsTHA6LDSsS_JnD_NIT5POs6ZGZ7R0wfFX8H9WzFS70oxaf4f5jK7Zh7viPab4oO-x8sGuY5GMcTbrGXlLXjk9Zbz8-16Qn58__bj-Ut1-u_l6_fG2GkUrlso5Dr0xwrWMMdOyBq0e2t5x1NIhdww7NjB00vUNaGOAo8OhhUGOfBC2Fxfk3e57SnEbdVGzzyNO034mxXqARkjB4f9oJ3jP23bYULajZcGcEzp1Sn7W6VExUFuI6qhKiGoLUQFXJcSi-bBrsKx77zGpPHoM5Sw-4bgoG_0_1M8qg6nY</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Picoloto, Rochele S.</creator><creator>Doneda, Morgana</creator><creator>Flores, Eder L.M.</creator><creator>Mesko, Marcia F.</creator><creator>Flores, Erico M.M.</creator><creator>Mello, Paola A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20150501</creationdate><title>Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion</title><author>Picoloto, Rochele S. ; Doneda, Morgana ; Flores, Eder L.M. ; Mesko, Marcia F. ; Flores, Erico M.M. ; Mello, Paola A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-ff208bb3f6111b614eda968f2ea5fe2f1e7191ef5f840abb02efe96095c293d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Bromine determination</topic><topic>Combustion</topic><topic>Digestion</topic><topic>ICP-MS</topic><topic>Infants</topic><topic>Iodine determination</topic><topic>Microwave-induced combustion</topic><topic>Milk</topic><topic>Milk powder</topic><topic>Nutrition</topic><topic>Samples</topic><topic>Statistical analysis</topic><topic>Statistical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Picoloto, Rochele S.</creatorcontrib><creatorcontrib>Doneda, Morgana</creatorcontrib><creatorcontrib>Flores, Eder L.M.</creatorcontrib><creatorcontrib>Mesko, Marcia F.</creatorcontrib><creatorcontrib>Flores, Erico M.M.</creatorcontrib><creatorcontrib>Mello, Paola A.</creatorcontrib><collection>CrossRef</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Spectrochimica acta. Part B: Atomic spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Picoloto, Rochele S.</au><au>Doneda, Morgana</au><au>Flores, Eder L.M.</au><au>Mesko, Marcia F.</au><au>Flores, Erico M.M.</au><au>Mello, Paola A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion</atitle><jtitle>Spectrochimica acta. Part B: Atomic spectroscopy</jtitle><date>2015-05-01</date><risdate>2015</risdate><volume>107</volume><spage>86</spage><epage>92</epage><pages>86-92</pages><issn>0584-8547</issn><eissn>1873-3565</eissn><abstract>In this work, bromine and iodine determination in milk powder for adult and infant nutrition was performed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion by microwave-induced combustion (MIC). Contrarily to previous works using MIC, a higher sample mass was digested (700 mg). Water and ammonium hydroxide (10 to 100mmolL−1) were investigated as absorbing solutions and accurate results were achieved using a 25mmolL−1 NH4OH solution. Moreover, the high stability of analytes after digestion (up to 30 days) using this solution was observed. The accuracy of the proposed MIC method was evaluated using certified and reference materials of milk powder (NIST 1549 and NIST 8435). No statistical difference was observed between results obtained by MIC-ICP-MS and reference values. Results for samples were also compared with those obtained by ICP-OES and no statistical difference was observed. Microwave-assisted alkaline extraction (MW-AE) was also evaluated for milk powder using NH4OH and tetramethylammonium hydroxide solutions. Solutions obtained after digestion by MIC (whole milk powder) presented low carbon content in digests (<25mgL−1) while solutions obtained after alkaline extraction presented up to 10,000mgL−1 of C. MIC method was preferable in view of the possibility of obtaining solutions with low carbon content even using a relatively high sample mass (up to 700mg) avoiding additional dilution prior to ICP-MS analysis, thus allowing better detection limits. Limits of detection obtained by MIC-ICP-MS were 0.007 and 0.003μgg−1 for Br and I, respectively, while for MW-AE were 0.1 and 0.05μgg−1 respectively for Br and I. Among the main advantages of the proposed method are the use of diluted alkaline solutions that is in agreement with green analytical chemistry recommendations, the high stability of analytes in solution and the suitability of digests for analysis by ICP-MS and also ICP-OES, minimizing memory effects and being advantageous for routine analysis.
•Microwave-induced combustion (MIC) was feasible for further Br and I determination by ICP-MS and ICP-OES.•MIC allowed a high milk powder mass digestion (700mg).•Only diluted solutions were necessary for analyte absorption.•Digests by MIC presented very low carbon content, avoiding interferences during Br and I determination.•A high throughput was obtained (8 samples digested in less than 25min including cooling step).</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.sab.2015.02.007</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0584-8547 |
ispartof | Spectrochimica acta. Part B: Atomic spectroscopy, 2015-05, Vol.107, p.86-92 |
issn | 0584-8547 1873-3565 |
language | eng |
recordid | cdi_proquest_miscellaneous_1800435320 |
source | Elsevier ScienceDirect Journals |
subjects | Bromine determination Combustion Digestion ICP-MS Infants Iodine determination Microwave-induced combustion Milk Milk powder Nutrition Samples Statistical analysis Statistical methods |
title | Simultaneous determination of bromine and iodine in milk powder for adult and infant nutrition by plasma based techniques after digestion using microwave-induced combustion |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T13%3A48%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simultaneous%20determination%20of%20bromine%20and%20iodine%20in%20milk%20powder%20for%20adult%20and%20infant%20nutrition%20by%20plasma%20based%20techniques%20after%20digestion%20using%20microwave-induced%20combustion&rft.jtitle=Spectrochimica%20acta.%20Part%20B:%20Atomic%20spectroscopy&rft.au=Picoloto,%20Rochele%20S.&rft.date=2015-05-01&rft.volume=107&rft.spage=86&rft.epage=92&rft.pages=86-92&rft.issn=0584-8547&rft.eissn=1873-3565&rft_id=info:doi/10.1016/j.sab.2015.02.007&rft_dat=%3Cproquest_cross%3E1800435320%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1732826690&rft_id=info:pmid/&rft_els_id=S0584854715000555&rfr_iscdi=true |