Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial

Background Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig‐to‐rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Xenotransplantation (Københaven) 2016-05, Vol.23 (3), p.202-210
Hauptverfasser: Kim, Dong Hyun, Kim, Jaeyoung, Jeong, Hyun Jeong, Lee, Hyun Ju, Kim, Mee Kum, Wee, Won Ryang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 210
container_issue 3
container_start_page 202
container_title Xenotransplantation (Københaven)
container_volume 23
creator Kim, Dong Hyun
Kim, Jaeyoung
Jeong, Hyun Jeong
Lee, Hyun Ju
Kim, Mee Kum
Wee, Won Ryang
description Background Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig‐to‐rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU) miniature pig (SNU pig, genetically unmodified) as donor tissues; however, there has been no biophysico‐functional evaluation of the SNU pig cornea as a substitute for human cornea. The purpose of this study was to investigate the biophysical and functional compatibility of SNU pig cornea for use in human clinical trials. Methods Ninety‐three eyeballs obtained from 51 SNU pigs were used to evaluate the physical properties and changes in porcine corneal endothelial cells (PCECs) depending on preservation time and storage condition before surgery, proliferative and functional characteristics of PCECs, and the microbiologic safety of porcine cornea. Corneal diameters and curvatures, axial length, anterior chamber depth, and central corneal thickness were measured and compared with previously reported human data. Corneal endothelial cell density (ECD) was serially measured with a confocal microscope during 7 days of preservation in the same storage solution used for human corneas. Corneal endothelial cell proliferation and immunofluorescence staining of Na‐ and K‐dependent ATPase in PCECs were evaluated after 7 days of preservation. The corneoscleral rims of SNU pigs were cultured for gram‐positive bacteria, gram‐negative bacteria, and fungi to evaluate their microbiological safety. Results Corneal diameter and thickness in SNU pigs was larger than human and corneal curvature was flatter; however, they were within surgically operable ranges. Mean ECD (day 0) and ECD loss after 7 days of preservation were 2625 ± 81 cells/mm2 and 7.60 ± 1.53%, respectively, which is comparable to human ECD and ECD loss in the same conditions. The ECD of SNU pigs was inversely decreased with aging (R2 = 0.4034, P = 0.001), and the estimated ages of pigs whose mean ECD would be more than 2500 and 2200 cells/mm2 or more were 48 and 72 months or less, respectively. Mean doubling time of the endothelial cells was 52 to 96 h depending on the method used. The Na‐ and K‐dependent ATPase pump in SNU pig cornea was well maintained for 7 days. No cultured microorganisms were found upon using the modified European Eye Bank Association protocol, which included additional antiseptic management du
doi_str_mv 10.1111/xen.12234
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1795874696</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1795874696</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4334-ebba805ead1024d359bc6c6da3453c4471a672dea83a3161305c89fb5923b6f3</originalsourceid><addsrcrecordid>eNp1kcFu1DAQhi0EokvhwAsgH9tDWjuOnfgIpbRIyyJoK_ZmTRyna3DiYCdt9z14YLxk2xu-WNZ8_6cZD0JvKTmh6Zw-mP6E5jkrnqEFZVJmjFTyOVoQSapMCL4-QK9i_EkIYbziL9FBXtKS5IQv0J8P1g-bbbTaZ-3U69H6HhzWvhtgtLV1dtxi3-Ir4yeHV7Cv3_T2zoS4Kx5drW6OcWd7C-MUDB7sbYqH3gCGiFNrfn45fBugHXHrAx43Bk_R7MSbqYMea5fyOjFjsOBeoxctuGje7O9DdP3p_PrsMlt-vfh89n6Z6YKxIjN1DRXhBhpK8qJhXNZaaNEAKzjTRVFSEGXeGKgYMCooI1xXsq25zFktWnaIjmbtEPzvycRRdTZq4xz0adqoaCl5VRZCioQez6gOPsZgWjUE20HYKkrUbgcqDar-7SCx7_baqe5M80Q-fnoCTmfg3jqz_b9Jrc9Xj8psTtg4moenBIRfSpSs5OrH6kJdFsv1x2_VF_Wd_QV1lKJx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1795874696</pqid></control><display><type>article</type><title>Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial</title><source>MEDLINE</source><source>Wiley Journals</source><creator>Kim, Dong Hyun ; Kim, Jaeyoung ; Jeong, Hyun Jeong ; Lee, Hyun Ju ; Kim, Mee Kum ; Wee, Won Ryang</creator><creatorcontrib>Kim, Dong Hyun ; Kim, Jaeyoung ; Jeong, Hyun Jeong ; Lee, Hyun Ju ; Kim, Mee Kum ; Wee, Won Ryang</creatorcontrib><description>Background Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig‐to‐rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU) miniature pig (SNU pig, genetically unmodified) as donor tissues; however, there has been no biophysico‐functional evaluation of the SNU pig cornea as a substitute for human cornea. The purpose of this study was to investigate the biophysical and functional compatibility of SNU pig cornea for use in human clinical trials. Methods Ninety‐three eyeballs obtained from 51 SNU pigs were used to evaluate the physical properties and changes in porcine corneal endothelial cells (PCECs) depending on preservation time and storage condition before surgery, proliferative and functional characteristics of PCECs, and the microbiologic safety of porcine cornea. Corneal diameters and curvatures, axial length, anterior chamber depth, and central corneal thickness were measured and compared with previously reported human data. Corneal endothelial cell density (ECD) was serially measured with a confocal microscope during 7 days of preservation in the same storage solution used for human corneas. Corneal endothelial cell proliferation and immunofluorescence staining of Na‐ and K‐dependent ATPase in PCECs were evaluated after 7 days of preservation. The corneoscleral rims of SNU pigs were cultured for gram‐positive bacteria, gram‐negative bacteria, and fungi to evaluate their microbiological safety. Results Corneal diameter and thickness in SNU pigs was larger than human and corneal curvature was flatter; however, they were within surgically operable ranges. Mean ECD (day 0) and ECD loss after 7 days of preservation were 2625 ± 81 cells/mm2 and 7.60 ± 1.53%, respectively, which is comparable to human ECD and ECD loss in the same conditions. The ECD of SNU pigs was inversely decreased with aging (R2 = 0.4034, P = 0.001), and the estimated ages of pigs whose mean ECD would be more than 2500 and 2200 cells/mm2 or more were 48 and 72 months or less, respectively. Mean doubling time of the endothelial cells was 52 to 96 h depending on the method used. The Na‐ and K‐dependent ATPase pump in SNU pig cornea was well maintained for 7 days. No cultured microorganisms were found upon using the modified European Eye Bank Association protocol, which included additional antiseptic management during the enucleation procedure. Conclusions In conclusion, SNU pig cornea is feasible for xenocorneal transplantation using the same preservation protocol as human with respect to biophysical and functional properties and can be stored for up to 7 days for transplantation in human clinical trials. An age limitation of donor pigs may be required for qualified corneal products to be used in human trials.</description><identifier>ISSN: 0908-665X</identifier><identifier>EISSN: 1399-3089</identifier><identifier>DOI: 10.1111/xen.12234</identifier><identifier>PMID: 27170205</identifier><language>eng</language><publisher>Denmark: Blackwell Publishing Ltd</publisher><subject>Animals ; biophysical and functional property ; Biophysical Phenomena ; cornea ; Cornea - cytology ; Cornea - immunology ; Cornea - surgery ; corneal endothelial cells ; Corneal Transplantation - methods ; preservation ; Seoul ; Seoul National University miniature pig ; Swine ; Swine, Miniature ; Transplantation, Heterologous - methods ; Universities ; xenotransplantation</subject><ispartof>Xenotransplantation (Københaven), 2016-05, Vol.23 (3), p.202-210</ispartof><rights>2016 John Wiley &amp; Sons A/S. Published by John Wiley &amp; Sons Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4334-ebba805ead1024d359bc6c6da3453c4471a672dea83a3161305c89fb5923b6f3</citedby><cites>FETCH-LOGICAL-c4334-ebba805ead1024d359bc6c6da3453c4471a672dea83a3161305c89fb5923b6f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fxen.12234$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fxen.12234$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27170205$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, Dong Hyun</creatorcontrib><creatorcontrib>Kim, Jaeyoung</creatorcontrib><creatorcontrib>Jeong, Hyun Jeong</creatorcontrib><creatorcontrib>Lee, Hyun Ju</creatorcontrib><creatorcontrib>Kim, Mee Kum</creatorcontrib><creatorcontrib>Wee, Won Ryang</creatorcontrib><title>Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial</title><title>Xenotransplantation (Københaven)</title><addtitle>Xenotransplantation</addtitle><description>Background Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig‐to‐rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU) miniature pig (SNU pig, genetically unmodified) as donor tissues; however, there has been no biophysico‐functional evaluation of the SNU pig cornea as a substitute for human cornea. The purpose of this study was to investigate the biophysical and functional compatibility of SNU pig cornea for use in human clinical trials. Methods Ninety‐three eyeballs obtained from 51 SNU pigs were used to evaluate the physical properties and changes in porcine corneal endothelial cells (PCECs) depending on preservation time and storage condition before surgery, proliferative and functional characteristics of PCECs, and the microbiologic safety of porcine cornea. Corneal diameters and curvatures, axial length, anterior chamber depth, and central corneal thickness were measured and compared with previously reported human data. Corneal endothelial cell density (ECD) was serially measured with a confocal microscope during 7 days of preservation in the same storage solution used for human corneas. Corneal endothelial cell proliferation and immunofluorescence staining of Na‐ and K‐dependent ATPase in PCECs were evaluated after 7 days of preservation. The corneoscleral rims of SNU pigs were cultured for gram‐positive bacteria, gram‐negative bacteria, and fungi to evaluate their microbiological safety. Results Corneal diameter and thickness in SNU pigs was larger than human and corneal curvature was flatter; however, they were within surgically operable ranges. Mean ECD (day 0) and ECD loss after 7 days of preservation were 2625 ± 81 cells/mm2 and 7.60 ± 1.53%, respectively, which is comparable to human ECD and ECD loss in the same conditions. The ECD of SNU pigs was inversely decreased with aging (R2 = 0.4034, P = 0.001), and the estimated ages of pigs whose mean ECD would be more than 2500 and 2200 cells/mm2 or more were 48 and 72 months or less, respectively. Mean doubling time of the endothelial cells was 52 to 96 h depending on the method used. The Na‐ and K‐dependent ATPase pump in SNU pig cornea was well maintained for 7 days. No cultured microorganisms were found upon using the modified European Eye Bank Association protocol, which included additional antiseptic management during the enucleation procedure. Conclusions In conclusion, SNU pig cornea is feasible for xenocorneal transplantation using the same preservation protocol as human with respect to biophysical and functional properties and can be stored for up to 7 days for transplantation in human clinical trials. An age limitation of donor pigs may be required for qualified corneal products to be used in human trials.</description><subject>Animals</subject><subject>biophysical and functional property</subject><subject>Biophysical Phenomena</subject><subject>cornea</subject><subject>Cornea - cytology</subject><subject>Cornea - immunology</subject><subject>Cornea - surgery</subject><subject>corneal endothelial cells</subject><subject>Corneal Transplantation - methods</subject><subject>preservation</subject><subject>Seoul</subject><subject>Seoul National University miniature pig</subject><subject>Swine</subject><subject>Swine, Miniature</subject><subject>Transplantation, Heterologous - methods</subject><subject>Universities</subject><subject>xenotransplantation</subject><issn>0908-665X</issn><issn>1399-3089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kcFu1DAQhi0EokvhwAsgH9tDWjuOnfgIpbRIyyJoK_ZmTRyna3DiYCdt9z14YLxk2xu-WNZ8_6cZD0JvKTmh6Zw-mP6E5jkrnqEFZVJmjFTyOVoQSapMCL4-QK9i_EkIYbziL9FBXtKS5IQv0J8P1g-bbbTaZ-3U69H6HhzWvhtgtLV1dtxi3-Ir4yeHV7Cv3_T2zoS4Kx5drW6OcWd7C-MUDB7sbYqH3gCGiFNrfn45fBugHXHrAx43Bk_R7MSbqYMea5fyOjFjsOBeoxctuGje7O9DdP3p_PrsMlt-vfh89n6Z6YKxIjN1DRXhBhpK8qJhXNZaaNEAKzjTRVFSEGXeGKgYMCooI1xXsq25zFktWnaIjmbtEPzvycRRdTZq4xz0adqoaCl5VRZCioQez6gOPsZgWjUE20HYKkrUbgcqDar-7SCx7_baqe5M80Q-fnoCTmfg3jqz_b9Jrc9Xj8psTtg4moenBIRfSpSs5OrH6kJdFsv1x2_VF_Wd_QV1lKJx</recordid><startdate>201605</startdate><enddate>201605</enddate><creator>Kim, Dong Hyun</creator><creator>Kim, Jaeyoung</creator><creator>Jeong, Hyun Jeong</creator><creator>Lee, Hyun Ju</creator><creator>Kim, Mee Kum</creator><creator>Wee, Won Ryang</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201605</creationdate><title>Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial</title><author>Kim, Dong Hyun ; Kim, Jaeyoung ; Jeong, Hyun Jeong ; Lee, Hyun Ju ; Kim, Mee Kum ; Wee, Won Ryang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4334-ebba805ead1024d359bc6c6da3453c4471a672dea83a3161305c89fb5923b6f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Animals</topic><topic>biophysical and functional property</topic><topic>Biophysical Phenomena</topic><topic>cornea</topic><topic>Cornea - cytology</topic><topic>Cornea - immunology</topic><topic>Cornea - surgery</topic><topic>corneal endothelial cells</topic><topic>Corneal Transplantation - methods</topic><topic>preservation</topic><topic>Seoul</topic><topic>Seoul National University miniature pig</topic><topic>Swine</topic><topic>Swine, Miniature</topic><topic>Transplantation, Heterologous - methods</topic><topic>Universities</topic><topic>xenotransplantation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Dong Hyun</creatorcontrib><creatorcontrib>Kim, Jaeyoung</creatorcontrib><creatorcontrib>Jeong, Hyun Jeong</creatorcontrib><creatorcontrib>Lee, Hyun Ju</creatorcontrib><creatorcontrib>Kim, Mee Kum</creatorcontrib><creatorcontrib>Wee, Won Ryang</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Xenotransplantation (Københaven)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Dong Hyun</au><au>Kim, Jaeyoung</au><au>Jeong, Hyun Jeong</au><au>Lee, Hyun Ju</au><au>Kim, Mee Kum</au><au>Wee, Won Ryang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial</atitle><jtitle>Xenotransplantation (Københaven)</jtitle><addtitle>Xenotransplantation</addtitle><date>2016-05</date><risdate>2016</risdate><volume>23</volume><issue>3</issue><spage>202</spage><epage>210</epage><pages>202-210</pages><issn>0908-665X</issn><eissn>1399-3089</eissn><abstract>Background Xenocorneal transplantation is one of the solutions for shortage of donor cornea, and remarkable advances have been made in pig‐to‐rhesus studies from the immunological perspective. Most successful preclinical trials have been carried out with corneas of the Seoul National University (SNU) miniature pig (SNU pig, genetically unmodified) as donor tissues; however, there has been no biophysico‐functional evaluation of the SNU pig cornea as a substitute for human cornea. The purpose of this study was to investigate the biophysical and functional compatibility of SNU pig cornea for use in human clinical trials. Methods Ninety‐three eyeballs obtained from 51 SNU pigs were used to evaluate the physical properties and changes in porcine corneal endothelial cells (PCECs) depending on preservation time and storage condition before surgery, proliferative and functional characteristics of PCECs, and the microbiologic safety of porcine cornea. Corneal diameters and curvatures, axial length, anterior chamber depth, and central corneal thickness were measured and compared with previously reported human data. Corneal endothelial cell density (ECD) was serially measured with a confocal microscope during 7 days of preservation in the same storage solution used for human corneas. Corneal endothelial cell proliferation and immunofluorescence staining of Na‐ and K‐dependent ATPase in PCECs were evaluated after 7 days of preservation. The corneoscleral rims of SNU pigs were cultured for gram‐positive bacteria, gram‐negative bacteria, and fungi to evaluate their microbiological safety. Results Corneal diameter and thickness in SNU pigs was larger than human and corneal curvature was flatter; however, they were within surgically operable ranges. Mean ECD (day 0) and ECD loss after 7 days of preservation were 2625 ± 81 cells/mm2 and 7.60 ± 1.53%, respectively, which is comparable to human ECD and ECD loss in the same conditions. The ECD of SNU pigs was inversely decreased with aging (R2 = 0.4034, P = 0.001), and the estimated ages of pigs whose mean ECD would be more than 2500 and 2200 cells/mm2 or more were 48 and 72 months or less, respectively. Mean doubling time of the endothelial cells was 52 to 96 h depending on the method used. The Na‐ and K‐dependent ATPase pump in SNU pig cornea was well maintained for 7 days. No cultured microorganisms were found upon using the modified European Eye Bank Association protocol, which included additional antiseptic management during the enucleation procedure. Conclusions In conclusion, SNU pig cornea is feasible for xenocorneal transplantation using the same preservation protocol as human with respect to biophysical and functional properties and can be stored for up to 7 days for transplantation in human clinical trials. An age limitation of donor pigs may be required for qualified corneal products to be used in human trials.</abstract><cop>Denmark</cop><pub>Blackwell Publishing Ltd</pub><pmid>27170205</pmid><doi>10.1111/xen.12234</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0908-665X
ispartof Xenotransplantation (Københaven), 2016-05, Vol.23 (3), p.202-210
issn 0908-665X
1399-3089
language eng
recordid cdi_proquest_miscellaneous_1795874696
source MEDLINE; Wiley Journals
subjects Animals
biophysical and functional property
Biophysical Phenomena
cornea
Cornea - cytology
Cornea - immunology
Cornea - surgery
corneal endothelial cells
Corneal Transplantation - methods
preservation
Seoul
Seoul National University miniature pig
Swine
Swine, Miniature
Transplantation, Heterologous - methods
Universities
xenotransplantation
title Biophysico-functional compatibility of Seoul National University (SNU) miniature pig cornea as xenocorneal graft for the use of human clinical trial
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T19%3A25%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biophysico-functional%20compatibility%20of%20Seoul%20National%20University%20(SNU)%20miniature%20pig%20cornea%20as%20xenocorneal%20graft%20for%20the%20use%20of%20human%20clinical%20trial&rft.jtitle=Xenotransplantation%20(K%C3%B8benhaven)&rft.au=Kim,%20Dong%20Hyun&rft.date=2016-05&rft.volume=23&rft.issue=3&rft.spage=202&rft.epage=210&rft.pages=202-210&rft.issn=0908-665X&rft.eissn=1399-3089&rft_id=info:doi/10.1111/xen.12234&rft_dat=%3Cproquest_cross%3E1795874696%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1795874696&rft_id=info:pmid/27170205&rfr_iscdi=true