Colour parameters and shade correspondence of CAD–CAM ceramic systems
Highlights • Spectral reflectance, colour parameters and colour differences between CAD–CAM ceramics and the corresponding nominal shade of Vita Classical shade guide were evaluated. • Colour differences were compared to the perceptibility and the acceptability thresholds. • None of the ceramic syst...
Gespeichert in:
Veröffentlicht in: | Journal of dentistry 2015-06, Vol.43 (6), p.726-734 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 734 |
---|---|
container_issue | 6 |
container_start_page | 726 |
container_title | Journal of dentistry |
container_volume | 43 |
creator | Della Bona, Alvaro Pecho, Oscar E Ghinea, Razvan Cardona, Juan C Pérez, María M |
description | Highlights • Spectral reflectance, colour parameters and colour differences between CAD–CAM ceramics and the corresponding nominal shade of Vita Classical shade guide were evaluated. • Colour differences were compared to the perceptibility and the acceptability thresholds. • None of the ceramic systems evaluated were able to properly match the corresponding nominal shade from Vita Classical shade guide. |
doi_str_mv | 10.1016/j.jdent.2015.02.015 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793287246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S030057121500055X</els_id><sourcerecordid>3690786281</sourcerecordid><originalsourceid>FETCH-LOGICAL-c590t-363f3af6d980f152cc0ecd8e1c9f0a9c3b98ccc5ccd0ba454937ace59ef015293</originalsourceid><addsrcrecordid>eNqFkk2O1DAQhS0EYpqBEyChSGzYJJTtOIkXILUCDEiDWADS7Cx3uSIc8tPYaaTecQduyElw6AGk2cyqNt-r0nuvGHvMoeDAq-d90TualkIAVwWIIo07bMObWue8rq7usg1IgFzVXJyxBzH2AFCC0PfZmVB12VQ1bNhFOw_zIWR7G-xIC4WY2cll8Yt1lOEcAsX9PKU7SNncZe321a8fP9vt-wwpCTxm8RgXGuNDdq-zQ6RH1_OcfX7z-lP7Nr_8cPGu3V7mqDQsuaxkJ21XOd1Ax5VABELXEEfdgdUod7pBRIXoYGdLVWpZWySlqUv2hJbn7Nlp7z7M3w4UFzP6iDQMdqL5EA2vtRRNLcrqdrRqpFQK5Io-vYH2KZQpGVkpIdJKsVLyRGGYYwzUmX3wow1Hw8GslZje_KnErJUYECaNpHpyvfuwG8n90_ztIAEvTgCl3L57CiaiXwN3PhAuxs3-lgMvb-hx8JNHO3ylI8X_TkxMAvNx_Yr1KbhKD6HUlfwNO5GyOA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1682232826</pqid></control><display><type>article</type><title>Colour parameters and shade correspondence of CAD–CAM ceramic systems</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Della Bona, Alvaro ; Pecho, Oscar E ; Ghinea, Razvan ; Cardona, Juan C ; Pérez, María M</creator><creatorcontrib>Della Bona, Alvaro ; Pecho, Oscar E ; Ghinea, Razvan ; Cardona, Juan C ; Pérez, María M</creatorcontrib><description>Highlights • Spectral reflectance, colour parameters and colour differences between CAD–CAM ceramics and the corresponding nominal shade of Vita Classical shade guide were evaluated. • Colour differences were compared to the perceptibility and the acceptability thresholds. • None of the ceramic systems evaluated were able to properly match the corresponding nominal shade from Vita Classical shade guide.</description><identifier>ISSN: 0300-5712</identifier><identifier>EISSN: 1879-176X</identifier><identifier>DOI: 10.1016/j.jdent.2015.02.015</identifier><identifier>PMID: 25748670</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Analysis of variance ; CADCAM ; Ceramics ; Ceramics - chemistry ; Color ; Colorimetry - instrumentation ; Colorimetry - methods ; Colour ; Composite Resins - chemistry ; Computer aided design ; Computer aided manufacturing ; Dental ceramics ; Dental Materials - chemistry ; Dental Porcelain - chemistry ; Dental Prosthesis Design ; Dentistry ; Prosthesis Coloring ; Reflectance ; Shades ; Standard deviation ; Surface Properties</subject><ispartof>Journal of dentistry, 2015-06, Vol.43 (6), p.726-734</ispartof><rights>Elsevier Ltd</rights><rights>2015 Elsevier Ltd</rights><rights>Copyright © 2015 Elsevier Ltd. All rights reserved.</rights><rights>Copyright Elsevier Limited Jun 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c590t-363f3af6d980f152cc0ecd8e1c9f0a9c3b98ccc5ccd0ba454937ace59ef015293</citedby><cites>FETCH-LOGICAL-c590t-363f3af6d980f152cc0ecd8e1c9f0a9c3b98ccc5ccd0ba454937ace59ef015293</cites><orcidid>0000-0002-8312-7503 ; 0000-0001-7314-5049</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S030057121500055X$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25748670$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Della Bona, Alvaro</creatorcontrib><creatorcontrib>Pecho, Oscar E</creatorcontrib><creatorcontrib>Ghinea, Razvan</creatorcontrib><creatorcontrib>Cardona, Juan C</creatorcontrib><creatorcontrib>Pérez, María M</creatorcontrib><title>Colour parameters and shade correspondence of CAD–CAM ceramic systems</title><title>Journal of dentistry</title><addtitle>J Dent</addtitle><description>Highlights • Spectral reflectance, colour parameters and colour differences between CAD–CAM ceramics and the corresponding nominal shade of Vita Classical shade guide were evaluated. • Colour differences were compared to the perceptibility and the acceptability thresholds. • None of the ceramic systems evaluated were able to properly match the corresponding nominal shade from Vita Classical shade guide.</description><subject>Analysis of variance</subject><subject>CADCAM</subject><subject>Ceramics</subject><subject>Ceramics - chemistry</subject><subject>Color</subject><subject>Colorimetry - instrumentation</subject><subject>Colorimetry - methods</subject><subject>Colour</subject><subject>Composite Resins - chemistry</subject><subject>Computer aided design</subject><subject>Computer aided manufacturing</subject><subject>Dental ceramics</subject><subject>Dental Materials - chemistry</subject><subject>Dental Porcelain - chemistry</subject><subject>Dental Prosthesis Design</subject><subject>Dentistry</subject><subject>Prosthesis Coloring</subject><subject>Reflectance</subject><subject>Shades</subject><subject>Standard deviation</subject><subject>Surface Properties</subject><issn>0300-5712</issn><issn>1879-176X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkk2O1DAQhS0EYpqBEyChSGzYJJTtOIkXILUCDEiDWADS7Cx3uSIc8tPYaaTecQduyElw6AGk2cyqNt-r0nuvGHvMoeDAq-d90TualkIAVwWIIo07bMObWue8rq7usg1IgFzVXJyxBzH2AFCC0PfZmVB12VQ1bNhFOw_zIWR7G-xIC4WY2cll8Yt1lOEcAsX9PKU7SNncZe321a8fP9vt-wwpCTxm8RgXGuNDdq-zQ6RH1_OcfX7z-lP7Nr_8cPGu3V7mqDQsuaxkJ21XOd1Ax5VABELXEEfdgdUod7pBRIXoYGdLVWpZWySlqUv2hJbn7Nlp7z7M3w4UFzP6iDQMdqL5EA2vtRRNLcrqdrRqpFQK5Io-vYH2KZQpGVkpIdJKsVLyRGGYYwzUmX3wow1Hw8GslZje_KnErJUYECaNpHpyvfuwG8n90_ztIAEvTgCl3L57CiaiXwN3PhAuxs3-lgMvb-hx8JNHO3ylI8X_TkxMAvNx_Yr1KbhKD6HUlfwNO5GyOA</recordid><startdate>20150601</startdate><enddate>20150601</enddate><creator>Della Bona, Alvaro</creator><creator>Pecho, Oscar E</creator><creator>Ghinea, Razvan</creator><creator>Cardona, Juan C</creator><creator>Pérez, María M</creator><general>Elsevier Ltd</general><general>Elsevier Limited</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QP</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8G</scope><scope>JG9</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8312-7503</orcidid><orcidid>https://orcid.org/0000-0001-7314-5049</orcidid></search><sort><creationdate>20150601</creationdate><title>Colour parameters and shade correspondence of CAD–CAM ceramic systems</title><author>Della Bona, Alvaro ; Pecho, Oscar E ; Ghinea, Razvan ; Cardona, Juan C ; Pérez, María M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c590t-363f3af6d980f152cc0ecd8e1c9f0a9c3b98ccc5ccd0ba454937ace59ef015293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Analysis of variance</topic><topic>CADCAM</topic><topic>Ceramics</topic><topic>Ceramics - chemistry</topic><topic>Color</topic><topic>Colorimetry - instrumentation</topic><topic>Colorimetry - methods</topic><topic>Colour</topic><topic>Composite Resins - chemistry</topic><topic>Computer aided design</topic><topic>Computer aided manufacturing</topic><topic>Dental ceramics</topic><topic>Dental Materials - chemistry</topic><topic>Dental Porcelain - chemistry</topic><topic>Dental Prosthesis Design</topic><topic>Dentistry</topic><topic>Prosthesis Coloring</topic><topic>Reflectance</topic><topic>Shades</topic><topic>Standard deviation</topic><topic>Surface Properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Della Bona, Alvaro</creatorcontrib><creatorcontrib>Pecho, Oscar E</creatorcontrib><creatorcontrib>Ghinea, Razvan</creatorcontrib><creatorcontrib>Cardona, Juan C</creatorcontrib><creatorcontrib>Pérez, María M</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Della Bona, Alvaro</au><au>Pecho, Oscar E</au><au>Ghinea, Razvan</au><au>Cardona, Juan C</au><au>Pérez, María M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Colour parameters and shade correspondence of CAD–CAM ceramic systems</atitle><jtitle>Journal of dentistry</jtitle><addtitle>J Dent</addtitle><date>2015-06-01</date><risdate>2015</risdate><volume>43</volume><issue>6</issue><spage>726</spage><epage>734</epage><pages>726-734</pages><issn>0300-5712</issn><eissn>1879-176X</eissn><abstract>Highlights • Spectral reflectance, colour parameters and colour differences between CAD–CAM ceramics and the corresponding nominal shade of Vita Classical shade guide were evaluated. • Colour differences were compared to the perceptibility and the acceptability thresholds. • None of the ceramic systems evaluated were able to properly match the corresponding nominal shade from Vita Classical shade guide.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>25748670</pmid><doi>10.1016/j.jdent.2015.02.015</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-8312-7503</orcidid><orcidid>https://orcid.org/0000-0001-7314-5049</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0300-5712 |
ispartof | Journal of dentistry, 2015-06, Vol.43 (6), p.726-734 |
issn | 0300-5712 1879-176X |
language | eng |
recordid | cdi_proquest_miscellaneous_1793287246 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Analysis of variance CADCAM Ceramics Ceramics - chemistry Color Colorimetry - instrumentation Colorimetry - methods Colour Composite Resins - chemistry Computer aided design Computer aided manufacturing Dental ceramics Dental Materials - chemistry Dental Porcelain - chemistry Dental Prosthesis Design Dentistry Prosthesis Coloring Reflectance Shades Standard deviation Surface Properties |
title | Colour parameters and shade correspondence of CAD–CAM ceramic systems |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T01%3A45%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Colour%20parameters%20and%20shade%20correspondence%20of%20CAD%E2%80%93CAM%20ceramic%20systems&rft.jtitle=Journal%20of%20dentistry&rft.au=Della%20Bona,%20Alvaro&rft.date=2015-06-01&rft.volume=43&rft.issue=6&rft.spage=726&rft.epage=734&rft.pages=726-734&rft.issn=0300-5712&rft.eissn=1879-176X&rft_id=info:doi/10.1016/j.jdent.2015.02.015&rft_dat=%3Cproquest_cross%3E3690786281%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1682232826&rft_id=info:pmid/25748670&rft_els_id=1_s2_0_S030057121500055X&rfr_iscdi=true |