Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple

In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosystems engineering 2016-03, Vol.143, p.9-19
Hauptverfasser: Fan, Shuxiang, Zhang, Baohua, Li, Jiangbo, Huang, Wenqian, Wang, Chaopeng
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 19
container_issue
container_start_page 9
container_title Biosystems engineering
container_volume 143
creator Fan, Shuxiang
Zhang, Baohua
Li, Jiangbo
Huang, Wenqian
Wang, Chaopeng
description In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation of spectrum measurement position a negligible interference for SSC prediction. •Effect of spectrum measurement position on NIR model of apple SSC was studied.•The spectrum measurement position affected the prediction accuracy of SSC.•The Global model based on effective wavelengths was robust.•A potential method for eliminating the effect of the spectrum measurement position.
doi_str_mv 10.1016/j.biosystemseng.2015.12.012
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793264140</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1537511015303470</els_id><sourcerecordid>1793264140</sourcerecordid><originalsourceid>FETCH-LOGICAL-c426t-99cc2de7bce8f67d3ee6b7e12e336d72aa201ec83090a2600d46ba2f7b029aec3</originalsourceid><addsrcrecordid>eNqNkF9LwzAUxYsoOKffIeCLL6tJ2iUrPsmYf2AoiD6HNL3VjLapuelgr35yUzcE34QL5zycc-D-kuSS0ZRRJq43aWkd7jBAi9C9p5yyecp4Shk_SiZsnsnZnPHi-NczepqcIW5oDMpcTJKvVV2DCcTVBPto_NCSFjQOHlroAukd2mBdR7baW_3j4oUPIN6VA4YOEMfy0-PLYcChcf2OtK6CBkntPEHXDGUDo9oKiXFdGKdjS_d9A-fJSa0bhIuDTpO3u9Xr8mG2fr5_XN6uZybnIsyKwhhegSwNLGohqwxAlBIYhywTleRax-_BLDJaUM0FpVUuSs1rWVJeaDDZNLna7_befQ6AQbUWDTSN7sANqJgsMi5yltMYvdlHTXwHPdSq97bVfqcYVSN5tVF_yKuRvGJcRfKxvdq3IwDYWvAKjYXOQGV9JKQqZ_-18w17uJkJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1793264140</pqid></control><display><type>article</type><title>Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Fan, Shuxiang ; Zhang, Baohua ; Li, Jiangbo ; Huang, Wenqian ; Wang, Chaopeng</creator><creatorcontrib>Fan, Shuxiang ; Zhang, Baohua ; Li, Jiangbo ; Huang, Wenqian ; Wang, Chaopeng</creatorcontrib><description>In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation of spectrum measurement position a negligible interference for SSC prediction. •Effect of spectrum measurement position on NIR model of apple SSC was studied.•The spectrum measurement position affected the prediction accuracy of SSC.•The Global model based on effective wavelengths was robust.•A potential method for eliminating the effect of the spectrum measurement position.</description><identifier>ISSN: 1537-5110</identifier><identifier>EISSN: 1537-5129</identifier><identifier>DOI: 10.1016/j.biosystemseng.2015.12.012</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Accuracy ; Apple ; Calibration ; Mathematical models ; NIR ; Position measurement ; Robustness ; Soluble solids content ; Spectra ; Spectroscopy ; Spectrum measurement position ; Wavelengths</subject><ispartof>Biosystems engineering, 2016-03, Vol.143, p.9-19</ispartof><rights>2015 IAgrE</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c426t-99cc2de7bce8f67d3ee6b7e12e336d72aa201ec83090a2600d46ba2f7b029aec3</citedby><cites>FETCH-LOGICAL-c426t-99cc2de7bce8f67d3ee6b7e12e336d72aa201ec83090a2600d46ba2f7b029aec3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.biosystemseng.2015.12.012$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Fan, Shuxiang</creatorcontrib><creatorcontrib>Zhang, Baohua</creatorcontrib><creatorcontrib>Li, Jiangbo</creatorcontrib><creatorcontrib>Huang, Wenqian</creatorcontrib><creatorcontrib>Wang, Chaopeng</creatorcontrib><title>Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple</title><title>Biosystems engineering</title><description>In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation of spectrum measurement position a negligible interference for SSC prediction. •Effect of spectrum measurement position on NIR model of apple SSC was studied.•The spectrum measurement position affected the prediction accuracy of SSC.•The Global model based on effective wavelengths was robust.•A potential method for eliminating the effect of the spectrum measurement position.</description><subject>Accuracy</subject><subject>Apple</subject><subject>Calibration</subject><subject>Mathematical models</subject><subject>NIR</subject><subject>Position measurement</subject><subject>Robustness</subject><subject>Soluble solids content</subject><subject>Spectra</subject><subject>Spectroscopy</subject><subject>Spectrum measurement position</subject><subject>Wavelengths</subject><issn>1537-5110</issn><issn>1537-5129</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqNkF9LwzAUxYsoOKffIeCLL6tJ2iUrPsmYf2AoiD6HNL3VjLapuelgr35yUzcE34QL5zycc-D-kuSS0ZRRJq43aWkd7jBAi9C9p5yyecp4Shk_SiZsnsnZnPHi-NczepqcIW5oDMpcTJKvVV2DCcTVBPto_NCSFjQOHlroAukd2mBdR7baW_3j4oUPIN6VA4YOEMfy0-PLYcChcf2OtK6CBkntPEHXDGUDo9oKiXFdGKdjS_d9A-fJSa0bhIuDTpO3u9Xr8mG2fr5_XN6uZybnIsyKwhhegSwNLGohqwxAlBIYhywTleRax-_BLDJaUM0FpVUuSs1rWVJeaDDZNLna7_befQ6AQbUWDTSN7sANqJgsMi5yltMYvdlHTXwHPdSq97bVfqcYVSN5tVF_yKuRvGJcRfKxvdq3IwDYWvAKjYXOQGV9JKQqZ_-18w17uJkJ</recordid><startdate>201603</startdate><enddate>201603</enddate><creator>Fan, Shuxiang</creator><creator>Zhang, Baohua</creator><creator>Li, Jiangbo</creator><creator>Huang, Wenqian</creator><creator>Wang, Chaopeng</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SU</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>201603</creationdate><title>Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple</title><author>Fan, Shuxiang ; Zhang, Baohua ; Li, Jiangbo ; Huang, Wenqian ; Wang, Chaopeng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c426t-99cc2de7bce8f67d3ee6b7e12e336d72aa201ec83090a2600d46ba2f7b029aec3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Accuracy</topic><topic>Apple</topic><topic>Calibration</topic><topic>Mathematical models</topic><topic>NIR</topic><topic>Position measurement</topic><topic>Robustness</topic><topic>Soluble solids content</topic><topic>Spectra</topic><topic>Spectroscopy</topic><topic>Spectrum measurement position</topic><topic>Wavelengths</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fan, Shuxiang</creatorcontrib><creatorcontrib>Zhang, Baohua</creatorcontrib><creatorcontrib>Li, Jiangbo</creatorcontrib><creatorcontrib>Huang, Wenqian</creatorcontrib><creatorcontrib>Wang, Chaopeng</creatorcontrib><collection>CrossRef</collection><collection>Environmental Engineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Biosystems engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fan, Shuxiang</au><au>Zhang, Baohua</au><au>Li, Jiangbo</au><au>Huang, Wenqian</au><au>Wang, Chaopeng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple</atitle><jtitle>Biosystems engineering</jtitle><date>2016-03</date><risdate>2016</risdate><volume>143</volume><spage>9</spage><epage>19</epage><pages>9-19</pages><issn>1537-5110</issn><eissn>1537-5129</eissn><abstract>In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation of spectrum measurement position a negligible interference for SSC prediction. •Effect of spectrum measurement position on NIR model of apple SSC was studied.•The spectrum measurement position affected the prediction accuracy of SSC.•The Global model based on effective wavelengths was robust.•A potential method for eliminating the effect of the spectrum measurement position.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.biosystemseng.2015.12.012</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1537-5110
ispartof Biosystems engineering, 2016-03, Vol.143, p.9-19
issn 1537-5110
1537-5129
language eng
recordid cdi_proquest_miscellaneous_1793264140
source Elsevier ScienceDirect Journals Complete
subjects Accuracy
Apple
Calibration
Mathematical models
NIR
Position measurement
Robustness
Soluble solids content
Spectra
Spectroscopy
Spectrum measurement position
Wavelengths
title Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-31T00%3A43%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20spectrum%20measurement%20position%20variation%20on%20the%20robustness%20of%20NIR%20spectroscopy%20models%20for%20soluble%20solids%20content%20of%20apple&rft.jtitle=Biosystems%20engineering&rft.au=Fan,%20Shuxiang&rft.date=2016-03&rft.volume=143&rft.spage=9&rft.epage=19&rft.pages=9-19&rft.issn=1537-5110&rft.eissn=1537-5129&rft_id=info:doi/10.1016/j.biosystemseng.2015.12.012&rft_dat=%3Cproquest_cross%3E1793264140%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1793264140&rft_id=info:pmid/&rft_els_id=S1537511015303470&rfr_iscdi=true