A study of pickup and signal processing for HLS-II bunch current measurement system

For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics C 2013-09, Vol.37 (9), p.80-83
1. Verfasser: 杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 83
container_issue 9
container_start_page 80
container_title Chinese physics C
container_volume 37
creator 杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平
description For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays over time and this will affect the performance of bunch current detection. To overcome the bunch stretch influence in the HLS-II bunch current measurement, an evaluation about pickup type and signal processing is carried out. Strip-line pickup and button pickup are selectable, and the theoretical analysis and demonstration experiment are performed to find out an acceptable solution for the bunch current measurement system at HLS-H. The experimental data analysis shows that the normalized calibration factor will change by about 27% when the bunch length changes by about 19% if using the button pickup and processing by peak value of bunch signal; the influence will be reduced to 2% less if adopting the strip-line pickup and integral.
doi_str_mv 10.1088/1674-1137/37/9/097006
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793258877</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>47067900</cqvip_id><sourcerecordid>1793258877</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-692c1c97c3667ebfe20c4475a4007f2cf802781c6968529a914869bf510dde1c3</originalsourceid><addsrcrecordid>eNo9kE1LAzEQhoMoWKs_QYg3L2sn2XxsjqWoLRQ8VM8hzSbt6n60ye6h_94sLYUXZg7POwwPQs8E3ggUxYwIyTJCcjlLUTNQEkDcoAlQzrIcOL1Fkytzjx5i_E0AS9UJ2sxx7IfyhDuPD5X9Gw7YtCWO1a41NT6EzroYq3aHfRfwcr3JViu8HVq7x3YIwbU9bpyJQ3DNuMdT7F3ziO68qaN7uswp-vl4_14ss_XX52oxX2c256rPhKKWWCVtLoR0W-8oWMYkNwxAemp9AVQWxAolCk6VUYQVQm09J1CWjth8il7Pd9Obx8HFXjdVtK6uTeu6IWoiVU55UUiZUH5GbehiDM7rQ6gaE06agB4l6lGQHgXpFKXPElPv5dLbd-3umERci0yCkAog_wf-iW8_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1793258877</pqid></control><display><type>article</type><title>A study of pickup and signal processing for HLS-II bunch current measurement system</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><source>Alma/SFX Local Collection</source><creator>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</creator><creatorcontrib>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</creatorcontrib><description>For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays over time and this will affect the performance of bunch current detection. To overcome the bunch stretch influence in the HLS-II bunch current measurement, an evaluation about pickup type and signal processing is carried out. Strip-line pickup and button pickup are selectable, and the theoretical analysis and demonstration experiment are performed to find out an acceptable solution for the bunch current measurement system at HLS-H. The experimental data analysis shows that the normalized calibration factor will change by about 27% when the bunch length changes by about 19% if using the button pickup and processing by peak value of bunch signal; the influence will be reduced to 2% less if adopting the strip-line pickup and integral.</description><identifier>ISSN: 1674-1137</identifier><identifier>EISSN: 0254-3052</identifier><identifier>DOI: 10.1088/1674-1137/37/9/097006</identifier><language>eng</language><subject>Acceptability ; Buttons ; Calibration ; Data processing ; DCCT ; Decay rate ; HLS储存环 ; Integrals ; Signal processing ; 信号处理 ; 实验数据分析 ; 校准因子 ; 测量系统 ; 电流测量 ; 皮卡</subject><ispartof>Chinese physics C, 2013-09, Vol.37 (9), p.80-83</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-692c1c97c3667ebfe20c4475a4007f2cf802781c6968529a914869bf510dde1c3</citedby><cites>FETCH-LOGICAL-c359t-692c1c97c3667ebfe20c4475a4007f2cf802781c6968529a914869bf510dde1c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/92043A/92043A.jpg</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</creatorcontrib><title>A study of pickup and signal processing for HLS-II bunch current measurement system</title><title>Chinese physics C</title><addtitle>Chinese Physica C</addtitle><description>For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays over time and this will affect the performance of bunch current detection. To overcome the bunch stretch influence in the HLS-II bunch current measurement, an evaluation about pickup type and signal processing is carried out. Strip-line pickup and button pickup are selectable, and the theoretical analysis and demonstration experiment are performed to find out an acceptable solution for the bunch current measurement system at HLS-H. The experimental data analysis shows that the normalized calibration factor will change by about 27% when the bunch length changes by about 19% if using the button pickup and processing by peak value of bunch signal; the influence will be reduced to 2% less if adopting the strip-line pickup and integral.</description><subject>Acceptability</subject><subject>Buttons</subject><subject>Calibration</subject><subject>Data processing</subject><subject>DCCT</subject><subject>Decay rate</subject><subject>HLS储存环</subject><subject>Integrals</subject><subject>Signal processing</subject><subject>信号处理</subject><subject>实验数据分析</subject><subject>校准因子</subject><subject>测量系统</subject><subject>电流测量</subject><subject>皮卡</subject><issn>1674-1137</issn><issn>0254-3052</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNo9kE1LAzEQhoMoWKs_QYg3L2sn2XxsjqWoLRQ8VM8hzSbt6n60ye6h_94sLYUXZg7POwwPQs8E3ggUxYwIyTJCcjlLUTNQEkDcoAlQzrIcOL1Fkytzjx5i_E0AS9UJ2sxx7IfyhDuPD5X9Gw7YtCWO1a41NT6EzroYq3aHfRfwcr3JViu8HVq7x3YIwbU9bpyJQ3DNuMdT7F3ziO68qaN7uswp-vl4_14ss_XX52oxX2c256rPhKKWWCVtLoR0W-8oWMYkNwxAemp9AVQWxAolCk6VUYQVQm09J1CWjth8il7Pd9Obx8HFXjdVtK6uTeu6IWoiVU55UUiZUH5GbehiDM7rQ6gaE06agB4l6lGQHgXpFKXPElPv5dLbd-3umERci0yCkAog_wf-iW8_</recordid><startdate>20130901</startdate><enddate>20130901</enddate><creator>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20130901</creationdate><title>A study of pickup and signal processing for HLS-II bunch current measurement system</title><author>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-692c1c97c3667ebfe20c4475a4007f2cf802781c6968529a914869bf510dde1c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Acceptability</topic><topic>Buttons</topic><topic>Calibration</topic><topic>Data processing</topic><topic>DCCT</topic><topic>Decay rate</topic><topic>HLS储存环</topic><topic>Integrals</topic><topic>Signal processing</topic><topic>信号处理</topic><topic>实验数据分析</topic><topic>校准因子</topic><topic>测量系统</topic><topic>电流测量</topic><topic>皮卡</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Chinese physics C</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>杨永良 马天骥 孙葆根 王季刚 邹俊颖 程超才 卢平</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A study of pickup and signal processing for HLS-II bunch current measurement system</atitle><jtitle>Chinese physics C</jtitle><addtitle>Chinese Physica C</addtitle><date>2013-09-01</date><risdate>2013</risdate><volume>37</volume><issue>9</issue><spage>80</spage><epage>83</epage><pages>80-83</pages><issn>1674-1137</issn><eissn>0254-3052</eissn><abstract>For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays over time and this will affect the performance of bunch current detection. To overcome the bunch stretch influence in the HLS-II bunch current measurement, an evaluation about pickup type and signal processing is carried out. Strip-line pickup and button pickup are selectable, and the theoretical analysis and demonstration experiment are performed to find out an acceptable solution for the bunch current measurement system at HLS-H. The experimental data analysis shows that the normalized calibration factor will change by about 27% when the bunch length changes by about 19% if using the button pickup and processing by peak value of bunch signal; the influence will be reduced to 2% less if adopting the strip-line pickup and integral.</abstract><doi>10.1088/1674-1137/37/9/097006</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1674-1137
ispartof Chinese physics C, 2013-09, Vol.37 (9), p.80-83
issn 1674-1137
0254-3052
language eng
recordid cdi_proquest_miscellaneous_1793258877
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link; Alma/SFX Local Collection
subjects Acceptability
Buttons
Calibration
Data processing
DCCT
Decay rate
HLS储存环
Integrals
Signal processing
信号处理
实验数据分析
校准因子
测量系统
电流测量
皮卡
title A study of pickup and signal processing for HLS-II bunch current measurement system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T18%3A42%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20study%20of%20pickup%20and%20signal%20processing%20for%20HLS-II%20bunch%20current%20measurement%20system&rft.jtitle=Chinese%20physics%20C&rft.au=%E6%9D%A8%E6%B0%B8%E8%89%AF%20%E9%A9%AC%E5%A4%A9%E9%AA%A5%20%E5%AD%99%E8%91%86%E6%A0%B9%20%E7%8E%8B%E5%AD%A3%E5%88%9A%20%E9%82%B9%E4%BF%8A%E9%A2%96%20%E7%A8%8B%E8%B6%85%E6%89%8D%20%E5%8D%A2%E5%B9%B3&rft.date=2013-09-01&rft.volume=37&rft.issue=9&rft.spage=80&rft.epage=83&rft.pages=80-83&rft.issn=1674-1137&rft.eissn=0254-3052&rft_id=info:doi/10.1088/1674-1137/37/9/097006&rft_dat=%3Cproquest_cross%3E1793258877%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1793258877&rft_id=info:pmid/&rft_cqvip_id=47067900&rfr_iscdi=true