Automatic calibration method of voxel size for cone-beam 3D-CT scanning system

For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics C 2014-04, Vol.38 (4), p.69-74
1. Verfasser: 杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 74
container_issue 4
container_start_page 69
container_title Chinese physics C
container_volume 38
creator 杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波
description For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy.
doi_str_mv 10.1088/1674-1137/38/4/046202
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793256889</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>49091192</cqvip_id><sourcerecordid>1793256889</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-d8a42d16888d1f02a52b7d39a9316290ae9ad34951cdc448dd4c294a24cbeb573</originalsourceid><addsrcrecordid>eNo9kMtOwzAURC0EEqXwCUhmx8bEz8ReVuUpVbApa8uxnTYosVs7RZSvJ1VRV3cWc0a6B4Bbgh8IlrIgZcURIawqmCx4gXlJMT0DE0wFRwwLeg4mp84luMr5C-OSj-gEvM92Q-zN0FpoTdfWaYwxwN4P6-hgbOB3_PEdzO2vh01M0MbgUe1ND9kjmi9htiaENqxg3ufB99fgojFd9jf_dwo-n5-W81e0-Hh5m88WyLJKDshJw6kjpZTSkQZTI2hdOaaMYqSkChuvjGNcCWKd5Vw6xy1V3FBua1-Lik3B_XF3k-J25_Og-zZb33Um-LjLmlSKUTHuq7EqjlWbYs7JN3qT2t6kvSZYH_zpgxt9cKOZ1Fwf_Y3c3T-3jmG1HX88gVxhRYii7A-87m3L</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1793256889</pqid></control><display><type>article</type><title>Automatic calibration method of voxel size for cone-beam 3D-CT scanning system</title><source>IOP Publishing Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>IOPscience extra</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><source>Alma/SFX Local Collection</source><creator>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</creator><creatorcontrib>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</creatorcontrib><description>For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy.</description><identifier>ISSN: 1674-1137</identifier><identifier>EISSN: 0254-3052</identifier><identifier>DOI: 10.1088/1674-1137/38/4/046202</identifier><language>eng</language><subject>Accuracy ; Automation ; Calibration ; Dynamical systems ; Linear equations ; Motion systems ; Scanning ; X-rays ; X-射线 ; 三维CT ; 像素 ; 扫描系统 ; 校准方法 ; 计算机断层扫描 ; 锥束 ; 非线性最小二乘拟合</subject><ispartof>Chinese physics C, 2014-04, Vol.38 (4), p.69-74</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-d8a42d16888d1f02a52b7d39a9316290ae9ad34951cdc448dd4c294a24cbeb573</citedby><cites>FETCH-LOGICAL-c378t-d8a42d16888d1f02a52b7d39a9316290ae9ad34951cdc448dd4c294a24cbeb573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/92043A/92043A.jpg</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</creatorcontrib><title>Automatic calibration method of voxel size for cone-beam 3D-CT scanning system</title><title>Chinese physics C</title><addtitle>Chinese Physica C</addtitle><description>For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy.</description><subject>Accuracy</subject><subject>Automation</subject><subject>Calibration</subject><subject>Dynamical systems</subject><subject>Linear equations</subject><subject>Motion systems</subject><subject>Scanning</subject><subject>X-rays</subject><subject>X-射线</subject><subject>三维CT</subject><subject>像素</subject><subject>扫描系统</subject><subject>校准方法</subject><subject>计算机断层扫描</subject><subject>锥束</subject><subject>非线性最小二乘拟合</subject><issn>1674-1137</issn><issn>0254-3052</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNo9kMtOwzAURC0EEqXwCUhmx8bEz8ReVuUpVbApa8uxnTYosVs7RZSvJ1VRV3cWc0a6B4Bbgh8IlrIgZcURIawqmCx4gXlJMT0DE0wFRwwLeg4mp84luMr5C-OSj-gEvM92Q-zN0FpoTdfWaYwxwN4P6-hgbOB3_PEdzO2vh01M0MbgUe1ND9kjmi9htiaENqxg3ufB99fgojFd9jf_dwo-n5-W81e0-Hh5m88WyLJKDshJw6kjpZTSkQZTI2hdOaaMYqSkChuvjGNcCWKd5Vw6xy1V3FBua1-Lik3B_XF3k-J25_Og-zZb33Um-LjLmlSKUTHuq7EqjlWbYs7JN3qT2t6kvSZYH_zpgxt9cKOZ1Fwf_Y3c3T-3jmG1HX88gVxhRYii7A-87m3L</recordid><startdate>20140401</startdate><enddate>20140401</enddate><creator>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20140401</creationdate><title>Automatic calibration method of voxel size for cone-beam 3D-CT scanning system</title><author>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-d8a42d16888d1f02a52b7d39a9316290ae9ad34951cdc448dd4c294a24cbeb573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Accuracy</topic><topic>Automation</topic><topic>Calibration</topic><topic>Dynamical systems</topic><topic>Linear equations</topic><topic>Motion systems</topic><topic>Scanning</topic><topic>X-rays</topic><topic>X-射线</topic><topic>三维CT</topic><topic>像素</topic><topic>扫描系统</topic><topic>校准方法</topic><topic>计算机断层扫描</topic><topic>锥束</topic><topic>非线性最小二乘拟合</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Chinese physics C</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>杨民 王晓龙 刘义鹏 孟凡勇 李兴东 刘文丽 魏东波</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automatic calibration method of voxel size for cone-beam 3D-CT scanning system</atitle><jtitle>Chinese physics C</jtitle><addtitle>Chinese Physica C</addtitle><date>2014-04-01</date><risdate>2014</risdate><volume>38</volume><issue>4</issue><spage>69</spage><epage>74</epage><pages>69-74</pages><issn>1674-1137</issn><eissn>0254-3052</eissn><abstract>For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy.</abstract><doi>10.1088/1674-1137/38/4/046202</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1674-1137
ispartof Chinese physics C, 2014-04, Vol.38 (4), p.69-74
issn 1674-1137
0254-3052
language eng
recordid cdi_proquest_miscellaneous_1793256889
source IOP Publishing Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; IOPscience extra; Institute of Physics (IOP) Journals - HEAL-Link; Alma/SFX Local Collection
subjects Accuracy
Automation
Calibration
Dynamical systems
Linear equations
Motion systems
Scanning
X-rays
X-射线
三维CT
像素
扫描系统
校准方法
计算机断层扫描
锥束
非线性最小二乘拟合
title Automatic calibration method of voxel size for cone-beam 3D-CT scanning system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T17%3A14%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automatic%20calibration%20method%20of%20voxel%20size%20for%20cone-beam%203D-CT%20scanning%20system&rft.jtitle=Chinese%20physics%20C&rft.au=%E6%9D%A8%E6%B0%91%20%E7%8E%8B%E6%99%93%E9%BE%99%20%E5%88%98%E4%B9%89%E9%B9%8F%20%E5%AD%9F%E5%87%A1%E5%8B%87%20%E6%9D%8E%E5%85%B4%E4%B8%9C%20%E5%88%98%E6%96%87%E4%B8%BD%20%E9%AD%8F%E4%B8%9C%E6%B3%A2&rft.date=2014-04-01&rft.volume=38&rft.issue=4&rft.spage=69&rft.epage=74&rft.pages=69-74&rft.issn=1674-1137&rft.eissn=0254-3052&rft_id=info:doi/10.1088/1674-1137/38/4/046202&rft_dat=%3Cproquest_cross%3E1793256889%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1793256889&rft_id=info:pmid/&rft_cqvip_id=49091192&rfr_iscdi=true