Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review

In-tube solid-phase microextraction (in-tube SPME or IT-SPME) is a sample preparation technique which has demonstrated over time its ability to couple with liquid chromatography (LC), as well as its advantages as a miniaturized technique. However, the in-tube SPME perspectives in the forthcoming yea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2016-02, Vol.906, p.41-57
Hauptverfasser: Fernández-Amado, M., Prieto-Blanco, M.C., López-Mahía, P., Muniategui-Lorenzo, S., Prada-Rodríguez, D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 57
container_issue
container_start_page 41
container_title Analytica chimica acta
container_volume 906
creator Fernández-Amado, M.
Prieto-Blanco, M.C.
López-Mahía, P.
Muniategui-Lorenzo, S.
Prada-Rodríguez, D.
description In-tube solid-phase microextraction (in-tube SPME or IT-SPME) is a sample preparation technique which has demonstrated over time its ability to couple with liquid chromatography (LC), as well as its advantages as a miniaturized technique. However, the in-tube SPME perspectives in the forthcoming years depend on solutions that can be brought to the environmental, industrial, food and biomedical analysis. The purpose of this scoping review is to examine the strengths and weaknesses of this technique during the period 2009 to 2015 in order to identify research gaps that should be addressed in the future, as well as the tendencies that are meant to strengthen the technique. In terms of methodological aspects, this scoping review shows the in-tube SPME strengths in the coupling with LC (LC-mass spectrometry, capillary LC, ultra-high-pressure LC), in the new performances (magnetic IT-SPME and electrochemically controlled in-tube SPME) and in the wide range of development of coatings and capillaries. Concerning the applicability, most in-tube SPME studies (around 80%) carry out environmental and biomedical analyses, a lower number food analyses and few industrial analyses. Some promising studies in proteomics have been performed. The review makes a critical description of parameters used in the optimization of in-tube SPME methods, highlighting the importance of some of them (i.e. type of capillary coatings). Commercial capillaries in environmental analysis and laboratory-prepared capillaries in biomedical analysis have been employed with good results. The most consolidated configuration is in-valve mode, however the cycle mode configuration is frequently chosen for biomedical analysis. This scoping review revealed that some aspects such as the combination of in-tube SPME with other sample treatment techniques for the analysis of solid samples should be developed in depth in the near future. [Display omitted] •A scoping review was carried out, which assesses the strengths and weaknesses of IT-SPME during the period 2009–2015.•Optimization parameters are discussed, with special emphasis on the most decisive ones.•New couplings, performances and capillaries as strength elements.•Benefits and drawbacks of the extraction modes and configurations.•IT-SPME applicability to different matrices and analytes.
doi_str_mv 10.1016/j.aca.2015.12.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793254996</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267015300350</els_id><sourcerecordid>1793254996</sourcerecordid><originalsourceid>FETCH-LOGICAL-c485t-154cd6655a6d7d1f2afbd791acd9c56b42b3bcb64053ce455037f7220e8b6cab3</originalsourceid><addsrcrecordid>eNqNkclOwzAQhi0EgrI8ABfkI5cE2_GSwAlVbBISQsDZ8jIBlzYpdsry9rhq4Yg4jWb0zX_4P4QOKSkpofJkUhpnSkaoKCkrCVEbaERrVRW8YnwTjQghVcGkIjtoN6VJXhklfBvt5JtilPERun8YInTPw0vCpvP4A8xrBylBwn2LQ1cMCws49dPgi_mLSYBnwcUePodo3BD67hSf4-T6eeiecYT3AB_7aKs10wQH67mHni4vHsfXxe3d1c34_LZwvBZDQQV3XkohjPTK05aZ1nrVUON844S0nNnKOis5EZUDLgSpVKsYI1Bb6Yyt9tDxKnce-7cFpEHPQnIwnZoO-kXSVDUVE7xp5D9QWYuacMH-g5JaqZo2GaUrNBeSUoRWz2OYmfilKdFLP3qisx-99KMp09lP_jlaxy_sDPzvx4-QDJytAMjV5TqjTi5A58CHCG7Qvg9_xH8DQfKfpA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1760877819</pqid></control><display><type>article</type><title>Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Fernández-Amado, M. ; Prieto-Blanco, M.C. ; López-Mahía, P. ; Muniategui-Lorenzo, S. ; Prada-Rodríguez, D.</creator><creatorcontrib>Fernández-Amado, M. ; Prieto-Blanco, M.C. ; López-Mahía, P. ; Muniategui-Lorenzo, S. ; Prada-Rodríguez, D.</creatorcontrib><description>In-tube solid-phase microextraction (in-tube SPME or IT-SPME) is a sample preparation technique which has demonstrated over time its ability to couple with liquid chromatography (LC), as well as its advantages as a miniaturized technique. However, the in-tube SPME perspectives in the forthcoming years depend on solutions that can be brought to the environmental, industrial, food and biomedical analysis. The purpose of this scoping review is to examine the strengths and weaknesses of this technique during the period 2009 to 2015 in order to identify research gaps that should be addressed in the future, as well as the tendencies that are meant to strengthen the technique. In terms of methodological aspects, this scoping review shows the in-tube SPME strengths in the coupling with LC (LC-mass spectrometry, capillary LC, ultra-high-pressure LC), in the new performances (magnetic IT-SPME and electrochemically controlled in-tube SPME) and in the wide range of development of coatings and capillaries. Concerning the applicability, most in-tube SPME studies (around 80%) carry out environmental and biomedical analyses, a lower number food analyses and few industrial analyses. Some promising studies in proteomics have been performed. The review makes a critical description of parameters used in the optimization of in-tube SPME methods, highlighting the importance of some of them (i.e. type of capillary coatings). Commercial capillaries in environmental analysis and laboratory-prepared capillaries in biomedical analysis have been employed with good results. The most consolidated configuration is in-valve mode, however the cycle mode configuration is frequently chosen for biomedical analysis. This scoping review revealed that some aspects such as the combination of in-tube SPME with other sample treatment techniques for the analysis of solid samples should be developed in depth in the near future. [Display omitted] •A scoping review was carried out, which assesses the strengths and weaknesses of IT-SPME during the period 2009–2015.•Optimization parameters are discussed, with special emphasis on the most decisive ones.•New couplings, performances and capillaries as strength elements.•Benefits and drawbacks of the extraction modes and configurations.•IT-SPME applicability to different matrices and analytes.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2015.12.007</identifier><identifier>PMID: 26772124</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Biomedical analysis ; Biomolecules ; Capillarity ; Chromatography, Liquid ; Coatings ; Environmental analysis ; Food analysis ; Foods ; In-tube SPME ; In-tube SPME couplings ; In-tube SPME parameters ; In-tube SPME performances ; IT-SPME ; Joining ; Liquid chromatography ; Mass Spectrometry ; Mathematical analysis ; Solid Phase Microextraction - methods ; Spectrometry ; Strength</subject><ispartof>Analytica chimica acta, 2016-02, Vol.906, p.41-57</ispartof><rights>2015 Elsevier B.V.</rights><rights>Copyright © 2015 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c485t-154cd6655a6d7d1f2afbd791acd9c56b42b3bcb64053ce455037f7220e8b6cab3</citedby><cites>FETCH-LOGICAL-c485t-154cd6655a6d7d1f2afbd791acd9c56b42b3bcb64053ce455037f7220e8b6cab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0003267015300350$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26772124$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fernández-Amado, M.</creatorcontrib><creatorcontrib>Prieto-Blanco, M.C.</creatorcontrib><creatorcontrib>López-Mahía, P.</creatorcontrib><creatorcontrib>Muniategui-Lorenzo, S.</creatorcontrib><creatorcontrib>Prada-Rodríguez, D.</creatorcontrib><title>Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>In-tube solid-phase microextraction (in-tube SPME or IT-SPME) is a sample preparation technique which has demonstrated over time its ability to couple with liquid chromatography (LC), as well as its advantages as a miniaturized technique. However, the in-tube SPME perspectives in the forthcoming years depend on solutions that can be brought to the environmental, industrial, food and biomedical analysis. The purpose of this scoping review is to examine the strengths and weaknesses of this technique during the period 2009 to 2015 in order to identify research gaps that should be addressed in the future, as well as the tendencies that are meant to strengthen the technique. In terms of methodological aspects, this scoping review shows the in-tube SPME strengths in the coupling with LC (LC-mass spectrometry, capillary LC, ultra-high-pressure LC), in the new performances (magnetic IT-SPME and electrochemically controlled in-tube SPME) and in the wide range of development of coatings and capillaries. Concerning the applicability, most in-tube SPME studies (around 80%) carry out environmental and biomedical analyses, a lower number food analyses and few industrial analyses. Some promising studies in proteomics have been performed. The review makes a critical description of parameters used in the optimization of in-tube SPME methods, highlighting the importance of some of them (i.e. type of capillary coatings). Commercial capillaries in environmental analysis and laboratory-prepared capillaries in biomedical analysis have been employed with good results. The most consolidated configuration is in-valve mode, however the cycle mode configuration is frequently chosen for biomedical analysis. This scoping review revealed that some aspects such as the combination of in-tube SPME with other sample treatment techniques for the analysis of solid samples should be developed in depth in the near future. [Display omitted] •A scoping review was carried out, which assesses the strengths and weaknesses of IT-SPME during the period 2009–2015.•Optimization parameters are discussed, with special emphasis on the most decisive ones.•New couplings, performances and capillaries as strength elements.•Benefits and drawbacks of the extraction modes and configurations.•IT-SPME applicability to different matrices and analytes.</description><subject>Biomedical analysis</subject><subject>Biomolecules</subject><subject>Capillarity</subject><subject>Chromatography, Liquid</subject><subject>Coatings</subject><subject>Environmental analysis</subject><subject>Food analysis</subject><subject>Foods</subject><subject>In-tube SPME</subject><subject>In-tube SPME couplings</subject><subject>In-tube SPME parameters</subject><subject>In-tube SPME performances</subject><subject>IT-SPME</subject><subject>Joining</subject><subject>Liquid chromatography</subject><subject>Mass Spectrometry</subject><subject>Mathematical analysis</subject><subject>Solid Phase Microextraction - methods</subject><subject>Spectrometry</subject><subject>Strength</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkclOwzAQhi0EgrI8ABfkI5cE2_GSwAlVbBISQsDZ8jIBlzYpdsry9rhq4Yg4jWb0zX_4P4QOKSkpofJkUhpnSkaoKCkrCVEbaERrVRW8YnwTjQghVcGkIjtoN6VJXhklfBvt5JtilPERun8YInTPw0vCpvP4A8xrBylBwn2LQ1cMCws49dPgi_mLSYBnwcUePodo3BD67hSf4-T6eeiecYT3AB_7aKs10wQH67mHni4vHsfXxe3d1c34_LZwvBZDQQV3XkohjPTK05aZ1nrVUON844S0nNnKOis5EZUDLgSpVKsYI1Bb6Yyt9tDxKnce-7cFpEHPQnIwnZoO-kXSVDUVE7xp5D9QWYuacMH-g5JaqZo2GaUrNBeSUoRWz2OYmfilKdFLP3qisx-99KMp09lP_jlaxy_sDPzvx4-QDJytAMjV5TqjTi5A58CHCG7Qvg9_xH8DQfKfpA</recordid><startdate>20160204</startdate><enddate>20160204</enddate><creator>Fernández-Amado, M.</creator><creator>Prieto-Blanco, M.C.</creator><creator>López-Mahía, P.</creator><creator>Muniategui-Lorenzo, S.</creator><creator>Prada-Rodríguez, D.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7SU</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20160204</creationdate><title>Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review</title><author>Fernández-Amado, M. ; Prieto-Blanco, M.C. ; López-Mahía, P. ; Muniategui-Lorenzo, S. ; Prada-Rodríguez, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c485t-154cd6655a6d7d1f2afbd791acd9c56b42b3bcb64053ce455037f7220e8b6cab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Biomedical analysis</topic><topic>Biomolecules</topic><topic>Capillarity</topic><topic>Chromatography, Liquid</topic><topic>Coatings</topic><topic>Environmental analysis</topic><topic>Food analysis</topic><topic>Foods</topic><topic>In-tube SPME</topic><topic>In-tube SPME couplings</topic><topic>In-tube SPME parameters</topic><topic>In-tube SPME performances</topic><topic>IT-SPME</topic><topic>Joining</topic><topic>Liquid chromatography</topic><topic>Mass Spectrometry</topic><topic>Mathematical analysis</topic><topic>Solid Phase Microextraction - methods</topic><topic>Spectrometry</topic><topic>Strength</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fernández-Amado, M.</creatorcontrib><creatorcontrib>Prieto-Blanco, M.C.</creatorcontrib><creatorcontrib>López-Mahía, P.</creatorcontrib><creatorcontrib>Muniategui-Lorenzo, S.</creatorcontrib><creatorcontrib>Prada-Rodríguez, D.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fernández-Amado, M.</au><au>Prieto-Blanco, M.C.</au><au>López-Mahía, P.</au><au>Muniategui-Lorenzo, S.</au><au>Prada-Rodríguez, D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2016-02-04</date><risdate>2016</risdate><volume>906</volume><spage>41</spage><epage>57</epage><pages>41-57</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>In-tube solid-phase microextraction (in-tube SPME or IT-SPME) is a sample preparation technique which has demonstrated over time its ability to couple with liquid chromatography (LC), as well as its advantages as a miniaturized technique. However, the in-tube SPME perspectives in the forthcoming years depend on solutions that can be brought to the environmental, industrial, food and biomedical analysis. The purpose of this scoping review is to examine the strengths and weaknesses of this technique during the period 2009 to 2015 in order to identify research gaps that should be addressed in the future, as well as the tendencies that are meant to strengthen the technique. In terms of methodological aspects, this scoping review shows the in-tube SPME strengths in the coupling with LC (LC-mass spectrometry, capillary LC, ultra-high-pressure LC), in the new performances (magnetic IT-SPME and electrochemically controlled in-tube SPME) and in the wide range of development of coatings and capillaries. Concerning the applicability, most in-tube SPME studies (around 80%) carry out environmental and biomedical analyses, a lower number food analyses and few industrial analyses. Some promising studies in proteomics have been performed. The review makes a critical description of parameters used in the optimization of in-tube SPME methods, highlighting the importance of some of them (i.e. type of capillary coatings). Commercial capillaries in environmental analysis and laboratory-prepared capillaries in biomedical analysis have been employed with good results. The most consolidated configuration is in-valve mode, however the cycle mode configuration is frequently chosen for biomedical analysis. This scoping review revealed that some aspects such as the combination of in-tube SPME with other sample treatment techniques for the analysis of solid samples should be developed in depth in the near future. [Display omitted] •A scoping review was carried out, which assesses the strengths and weaknesses of IT-SPME during the period 2009–2015.•Optimization parameters are discussed, with special emphasis on the most decisive ones.•New couplings, performances and capillaries as strength elements.•Benefits and drawbacks of the extraction modes and configurations.•IT-SPME applicability to different matrices and analytes.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>26772124</pmid><doi>10.1016/j.aca.2015.12.007</doi><tpages>17</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2016-02, Vol.906, p.41-57
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_1793254996
source MEDLINE; Elsevier ScienceDirect Journals
subjects Biomedical analysis
Biomolecules
Capillarity
Chromatography, Liquid
Coatings
Environmental analysis
Food analysis
Foods
In-tube SPME
In-tube SPME couplings
In-tube SPME parameters
In-tube SPME performances
IT-SPME
Joining
Liquid chromatography
Mass Spectrometry
Mathematical analysis
Solid Phase Microextraction - methods
Spectrometry
Strength
title Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T08%3A31%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Strengths%20and%20weaknesses%20of%20in-tube%20solid-phase%20microextraction:%20A%20scoping%20review&rft.jtitle=Analytica%20chimica%20acta&rft.au=Fern%C3%A1ndez-Amado,%20M.&rft.date=2016-02-04&rft.volume=906&rft.spage=41&rft.epage=57&rft.pages=41-57&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/j.aca.2015.12.007&rft_dat=%3Cproquest_cross%3E1793254996%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1760877819&rft_id=info:pmid/26772124&rft_els_id=S0003267015300350&rfr_iscdi=true