The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties

In order to meet the need of medicine packing industry for Mechanical Properties such as high speed and accuracy, the electronic granulation counter is developed. The counter consists of LED light source, double linear array CCD sensors TCD1209D, synchronously driving circuit for double linear array...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advanced Materials Research 2013-01, Vol.644, p.47-50
Hauptverfasser: Sui, Xiu Wu, Sui, Xiu Mei, Liu, Lei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 50
container_issue
container_start_page 47
container_title Advanced Materials Research
container_volume 644
creator Sui, Xiu Wu
Sui, Xiu Mei
Liu, Lei
description In order to meet the need of medicine packing industry for Mechanical Properties such as high speed and accuracy, the electronic granulation counter is developed. The counter consists of LED light source, double linear array CCD sensors TCD1209D, synchronously driving circuit for double linear array CCD based on CPLD EPM3064A, synchronously data acquisition card with A/D converter TLC 5510 of the high speed, and host computer. The test channel is 400 millimeter wide, the horizontal resolution is 0.1 millimeter, the driving frequency of linear array CCD sensors is 10 MHz and the vertical resolution is 0.3 millimeter, software binarization is effective for identifying the medicine tablets of different light transmittance. The experiments show the electronic granulation counter is accurate and reliable, counting speed is over 8000 per minute, and can distinguish the broken tablets and the overlap tablets.
doi_str_mv 10.4028/www.scientific.net/AMR.644.47
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1793249224</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1793249224</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-be86057277f9d4d94e77615caf164ea268044eeddf9fff42743ac12ccd97b583</originalsourceid><addsrcrecordid>eNqNkE1LAzEQhoMfYNX-h70IXnbNZrP5OIjUWqtQUaQnLyFmJ3TLdlOTrMV_b6SCV08zzLzzMu-D0EWJC4qJuNrtdkUwLfSxta0peohXk6fXglFaUH6ARiVjJBdS1IdoLLmocMVFzTChR2mHCckZE_gEnYawxpjRktQj9LZcQXYHn9C57SY5Z85mkyG6jY6tyWYdmOhdn9q51_3Qpanrs6kb-gg-u9UBmiwNnsCsdFLpLnvxbgs-thDO0bHVXYDxbz1Dy_vZcvqQL57nj9PJIjdEipi_g2C45oRzKxvaSAqcs7I22paMgibpZ0oBmsZKay0lnFbalMSYRvL3WlRn6HJvu_XuY4AQ1aYNBrpO9-CGoEouK0IlITRJr_dS410IHqza-naj_ZcqsfpBrBJi9YdYJcQqIVYJsaI83d_s72OCEWIKrdZu8H1K90-HbyQkjFk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1793249224</pqid></control><display><type>article</type><title>The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties</title><source>Scientific.net Journals</source><creator>Sui, Xiu Wu ; Sui, Xiu Mei ; Liu, Lei</creator><creatorcontrib>Sui, Xiu Wu ; Sui, Xiu Mei ; Liu, Lei</creatorcontrib><description>In order to meet the need of medicine packing industry for Mechanical Properties such as high speed and accuracy, the electronic granulation counter is developed. The counter consists of LED light source, double linear array CCD sensors TCD1209D, synchronously driving circuit for double linear array CCD based on CPLD EPM3064A, synchronously data acquisition card with A/D converter TLC 5510 of the high speed, and host computer. The test channel is 400 millimeter wide, the horizontal resolution is 0.1 millimeter, the driving frequency of linear array CCD sensors is 10 MHz and the vertical resolution is 0.3 millimeter, software binarization is effective for identifying the medicine tablets of different light transmittance. The experiments show the electronic granulation counter is accurate and reliable, counting speed is over 8000 per minute, and can distinguish the broken tablets and the overlap tablets.</description><identifier>ISSN: 1022-6680</identifier><identifier>ISSN: 1662-8985</identifier><identifier>ISBN: 9783037856024</identifier><identifier>ISBN: 3037856025</identifier><identifier>EISSN: 1662-8985</identifier><identifier>DOI: 10.4028/www.scientific.net/AMR.644.47</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><subject>Electronics ; Granulation ; High speed ; Linear arrays ; Mechanical properties ; Medicine ; Sensors ; Tablets</subject><ispartof>Advanced Materials Research, 2013-01, Vol.644, p.47-50</ispartof><rights>2013 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c298t-be86057277f9d4d94e77615caf164ea268044eeddf9fff42743ac12ccd97b583</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/2225?width=600</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Sui, Xiu Wu</creatorcontrib><creatorcontrib>Sui, Xiu Mei</creatorcontrib><creatorcontrib>Liu, Lei</creatorcontrib><title>The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties</title><title>Advanced Materials Research</title><description>In order to meet the need of medicine packing industry for Mechanical Properties such as high speed and accuracy, the electronic granulation counter is developed. The counter consists of LED light source, double linear array CCD sensors TCD1209D, synchronously driving circuit for double linear array CCD based on CPLD EPM3064A, synchronously data acquisition card with A/D converter TLC 5510 of the high speed, and host computer. The test channel is 400 millimeter wide, the horizontal resolution is 0.1 millimeter, the driving frequency of linear array CCD sensors is 10 MHz and the vertical resolution is 0.3 millimeter, software binarization is effective for identifying the medicine tablets of different light transmittance. The experiments show the electronic granulation counter is accurate and reliable, counting speed is over 8000 per minute, and can distinguish the broken tablets and the overlap tablets.</description><subject>Electronics</subject><subject>Granulation</subject><subject>High speed</subject><subject>Linear arrays</subject><subject>Mechanical properties</subject><subject>Medicine</subject><subject>Sensors</subject><subject>Tablets</subject><issn>1022-6680</issn><issn>1662-8985</issn><issn>1662-8985</issn><isbn>9783037856024</isbn><isbn>3037856025</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LAzEQhoMfYNX-h70IXnbNZrP5OIjUWqtQUaQnLyFmJ3TLdlOTrMV_b6SCV08zzLzzMu-D0EWJC4qJuNrtdkUwLfSxta0peohXk6fXglFaUH6ARiVjJBdS1IdoLLmocMVFzTChR2mHCckZE_gEnYawxpjRktQj9LZcQXYHn9C57SY5Z85mkyG6jY6tyWYdmOhdn9q51_3Qpanrs6kb-gg-u9UBmiwNnsCsdFLpLnvxbgs-thDO0bHVXYDxbz1Dy_vZcvqQL57nj9PJIjdEipi_g2C45oRzKxvaSAqcs7I22paMgibpZ0oBmsZKay0lnFbalMSYRvL3WlRn6HJvu_XuY4AQ1aYNBrpO9-CGoEouK0IlITRJr_dS410IHqza-naj_ZcqsfpBrBJi9YdYJcQqIVYJsaI83d_s72OCEWIKrdZu8H1K90-HbyQkjFk</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Sui, Xiu Wu</creator><creator>Sui, Xiu Mei</creator><creator>Liu, Lei</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QQ</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20130101</creationdate><title>The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties</title><author>Sui, Xiu Wu ; Sui, Xiu Mei ; Liu, Lei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-be86057277f9d4d94e77615caf164ea268044eeddf9fff42743ac12ccd97b583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Electronics</topic><topic>Granulation</topic><topic>High speed</topic><topic>Linear arrays</topic><topic>Mechanical properties</topic><topic>Medicine</topic><topic>Sensors</topic><topic>Tablets</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sui, Xiu Wu</creatorcontrib><creatorcontrib>Sui, Xiu Mei</creatorcontrib><creatorcontrib>Liu, Lei</creatorcontrib><collection>CrossRef</collection><collection>Ceramic Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Advanced Materials Research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sui, Xiu Wu</au><au>Sui, Xiu Mei</au><au>Liu, Lei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties</atitle><jtitle>Advanced Materials Research</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>644</volume><spage>47</spage><epage>50</epage><pages>47-50</pages><issn>1022-6680</issn><issn>1662-8985</issn><eissn>1662-8985</eissn><isbn>9783037856024</isbn><isbn>3037856025</isbn><abstract>In order to meet the need of medicine packing industry for Mechanical Properties such as high speed and accuracy, the electronic granulation counter is developed. The counter consists of LED light source, double linear array CCD sensors TCD1209D, synchronously driving circuit for double linear array CCD based on CPLD EPM3064A, synchronously data acquisition card with A/D converter TLC 5510 of the high speed, and host computer. The test channel is 400 millimeter wide, the horizontal resolution is 0.1 millimeter, the driving frequency of linear array CCD sensors is 10 MHz and the vertical resolution is 0.3 millimeter, software binarization is effective for identifying the medicine tablets of different light transmittance. The experiments show the electronic granulation counter is accurate and reliable, counting speed is over 8000 per minute, and can distinguish the broken tablets and the overlap tablets.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMR.644.47</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1022-6680
ispartof Advanced Materials Research, 2013-01, Vol.644, p.47-50
issn 1022-6680
1662-8985
1662-8985
language eng
recordid cdi_proquest_miscellaneous_1793249224
source Scientific.net Journals
subjects Electronics
Granulation
High speed
Linear arrays
Mechanical properties
Medicine
Sensors
Tablets
title The Development of Automatic Electronic Granulation Counter Based on Mechanical Properties
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T07%3A57%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Development%20of%20Automatic%20Electronic%20Granulation%20Counter%20Based%20on%20Mechanical%20Properties&rft.jtitle=Advanced%20Materials%20Research&rft.au=Sui,%20Xiu%20Wu&rft.date=2013-01-01&rft.volume=644&rft.spage=47&rft.epage=50&rft.pages=47-50&rft.issn=1022-6680&rft.eissn=1662-8985&rft.isbn=9783037856024&rft.isbn_list=3037856025&rft_id=info:doi/10.4028/www.scientific.net/AMR.644.47&rft_dat=%3Cproquest_cross%3E1793249224%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1793249224&rft_id=info:pmid/&rfr_iscdi=true