Impact of Advance Control on Microturbine Generation System Performance
Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigat...
Gespeichert in:
Veröffentlicht in: | IOP conference series. Earth and environmental science 2013-01, Vol.16 (1), p.1-4 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | 1 |
container_start_page | 1 |
container_title | IOP conference series. Earth and environmental science |
container_volume | 16 |
creator | Hussin, Ahmad Kamil Mat Wanik, Mohd Zamri Che |
description | Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier. |
doi_str_mv | 10.1088/1755-1315/16/1/012018 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1786177040</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2534293400</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</originalsourceid><addsrcrecordid>eNqFUcFKxDAQDaLguvoJQsGLl7WZpJOkx2XRdWFFQT2HNE2hS9usSSvs39uyIuLFy8zwePOYeY-Qa6B3QJVKQSIugAOmIFJIKTAK6oTMfvDTX_M5uYhxR6mQGc9nZL1p98b2ia-SZflpOuuSle_64JvEd8lTbYPvh1DUnUvWrnPB9PWIvx5i79rkxYXKh3bauiRnlWmiu_ruc_L-cP-2elxsn9eb1XK7sDxj_VhLhlayUgojGTcGCiwcywFziZXKqMkMKIDcsByrwtiiRLSqREp5lUnD5-T2qLsP_mNwsddtHa1rGtM5P0QNUgmQkmb0fyoKobhArkbqzR_qzg-hGx_RDMfDc57RSRCPrNGUGIOr9D7UrQkHDVRPSejJZT25rEFo0Mck-Bdz6Hnr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2534293400</pqid></control><display><type>article</type><title>Impact of Advance Control on Microturbine Generation System Performance</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Institute of Physics Open Access Journal Titles</source><source>IOPscience extra</source><creator>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</creator><creatorcontrib>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</creatorcontrib><description>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</description><identifier>ISSN: 1755-1315</identifier><identifier>ISSN: 1755-1307</identifier><identifier>EISSN: 1755-1315</identifier><identifier>DOI: 10.1088/1755-1315/16/1/012018</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Control systems ; Earth ; Energy conversion ; Faults ; Rectifiers ; Riding ; Simulation ; Topology</subject><ispartof>IOP conference series. Earth and environmental science, 2013-01, Vol.16 (1), p.1-4</ispartof><rights>2013. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Hussin, Ahmad Kamil Mat</creatorcontrib><creatorcontrib>Wanik, Mohd Zamri Che</creatorcontrib><title>Impact of Advance Control on Microturbine Generation System Performance</title><title>IOP conference series. Earth and environmental science</title><description>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</description><subject>Control systems</subject><subject>Earth</subject><subject>Energy conversion</subject><subject>Faults</subject><subject>Rectifiers</subject><subject>Riding</subject><subject>Simulation</subject><subject>Topology</subject><issn>1755-1315</issn><issn>1755-1307</issn><issn>1755-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqFUcFKxDAQDaLguvoJQsGLl7WZpJOkx2XRdWFFQT2HNE2hS9usSSvs39uyIuLFy8zwePOYeY-Qa6B3QJVKQSIugAOmIFJIKTAK6oTMfvDTX_M5uYhxR6mQGc9nZL1p98b2ia-SZflpOuuSle_64JvEd8lTbYPvh1DUnUvWrnPB9PWIvx5i79rkxYXKh3bauiRnlWmiu_ruc_L-cP-2elxsn9eb1XK7sDxj_VhLhlayUgojGTcGCiwcywFziZXKqMkMKIDcsByrwtiiRLSqREp5lUnD5-T2qLsP_mNwsddtHa1rGtM5P0QNUgmQkmb0fyoKobhArkbqzR_qzg-hGx_RDMfDc57RSRCPrNGUGIOr9D7UrQkHDVRPSejJZT25rEFo0Mck-Bdz6Hnr</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Hussin, Ahmad Kamil Mat</creator><creator>Wanik, Mohd Zamri Che</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>PATMY</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PYCSY</scope><scope>7QH</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H95</scope><scope>H97</scope><scope>L.G</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20130101</creationdate><title>Impact of Advance Control on Microturbine Generation System Performance</title><author>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Control systems</topic><topic>Earth</topic><topic>Energy conversion</topic><topic>Faults</topic><topic>Rectifiers</topic><topic>Riding</topic><topic>Simulation</topic><topic>Topology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hussin, Ahmad Kamil Mat</creatorcontrib><creatorcontrib>Wanik, Mohd Zamri Che</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Agricultural & Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Environmental Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Environmental Science Collection</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 1: Biological Sciences & Living Resources</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IOP conference series. Earth and environmental science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hussin, Ahmad Kamil Mat</au><au>Wanik, Mohd Zamri Che</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of Advance Control on Microturbine Generation System Performance</atitle><jtitle>IOP conference series. Earth and environmental science</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>16</volume><issue>1</issue><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>1755-1315</issn><issn>1755-1307</issn><eissn>1755-1315</eissn><abstract>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1755-1315/16/1/012018</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1755-1315 |
ispartof | IOP conference series. Earth and environmental science, 2013-01, Vol.16 (1), p.1-4 |
issn | 1755-1315 1755-1307 1755-1315 |
language | eng |
recordid | cdi_proquest_miscellaneous_1786177040 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Institute of Physics Open Access Journal Titles; IOPscience extra |
subjects | Control systems Earth Energy conversion Faults Rectifiers Riding Simulation Topology |
title | Impact of Advance Control on Microturbine Generation System Performance |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T00%3A55%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20Advance%20Control%20on%20Microturbine%20Generation%20System%20Performance&rft.jtitle=IOP%20conference%20series.%20Earth%20and%20environmental%20science&rft.au=Hussin,%20Ahmad%20Kamil%20Mat&rft.date=2013-01-01&rft.volume=16&rft.issue=1&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=1755-1315&rft.eissn=1755-1315&rft_id=info:doi/10.1088/1755-1315/16/1/012018&rft_dat=%3Cproquest_cross%3E2534293400%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2534293400&rft_id=info:pmid/&rfr_iscdi=true |