Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time?
Background A fine needle aspiration biopsy (FNAB) of thyroid nodules – the least invasive and most accurate method used to investigate malignant lesions – may yield non-diagnostic specimens even under ultrasonographic guidance. Purpose To evaluate the effects of thyroid nodule volume and extent of c...
Gespeichert in:
Veröffentlicht in: | Acta radiologica (1987) 2015-10, Vol.56 (10), p.1203-1208 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1208 |
---|---|
container_issue | 10 |
container_start_page | 1203 |
container_title | Acta radiologica (1987) |
container_volume | 56 |
creator | Cengic, Ismet Tureli, Derya Ozden, Ferhat Bugdayci, Onur Aydin, Hilal Aribal, Erkin |
description | Background
A fine needle aspiration biopsy (FNAB) of thyroid nodules – the least invasive and most accurate method used to investigate malignant lesions – may yield non-diagnostic specimens even under ultrasonographic guidance.
Purpose
To evaluate the effects of thyroid nodule volume and extent of cystic degeneration on both the non-diagnostic specimen ratio as well as cytopathologist’s definitive cytological diagnosis time.
Material and Methods
In this single center study, FNAB was performed on 505 patients with single thyroid nodules greater than 10 mm. Nodule volume was calculated prior to FNAB and cystic degeneration ratio was recorded. All biopsies were performed by a single radiologist who also prepared specimen slides. Specimen adequacy and final diagnosis were made in the pathology laboratory by a single-blinded cytopathologist based on the Bethesda system. Definitive cytological diagnosis time was recorded upon reaching a definitive diagnosis.
Results
The specimen adequacy ratio was 85.3%. The mean nodule volume of adequate specimens was larger than those of non-diagnostic samples (6.00 mL vs. 3.05 mL; P = 0.001). There was no correlation between nodule volume and cytopathologist’s definitive cytological diagnosis time (r = 0.042). Biopsy of predominantly solid nodules yielded better specimen adequacy ratios compared to predominantly cystic nodules (87.8% vs. 75.3%; P = 0.028). Definitive cytological diagnosis times were longer in predominantly cystic nodules compared to predominantly solid nodules (376 s vs. 294 s; P = 0.019).
Conclusion
Predominantly cystic nodules are likely to benefit from repeated nodular sampling until the specimen is declared adequate by an on-site cytopathologist. If a cytopathologist is not available, obtaining more specimens per nodule may achieve desired adequacy ratios. |
doi_str_mv | 10.1177/0284185114554825 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1786170727</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0284185114554825</sage_id><sourcerecordid>1708898175</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-f077a7667ca45a661bea2071a170b91d5ad5fa8670227014b256161a735c7a923</originalsourceid><addsrcrecordid>eNqNkUFv1DAQhS0EotvCnRPykUvA4409WS4IVS1FqtRLOUcTe7K4Suw0TpDyJ_jNZNmFAxJST0-j9713mCfEG1DvARA_KF2VUBmA0piy0uaZ2IBVqlDr_VxsDnZx8M_Eec4PSoFGAy_FmTbbsjRKb8TP--_LmIKXbYgsI7PvWFIewkhTSFE2IQ15-Sh9kjH5eTV_pG7uVyZ66ZY8BSc97znyKfBbJLUtu0nmgV3oOUry_DiTW06xKXVpHxx10gfax5RDltMKfnolXrTUZX590gvx7frq_vKmuL378vXy823htqimolWIhNaio9KQtdAwaYVAgKrZgTfkTUuVRaU1KigbbSxYINwah7TT2wvx7tg7jOlx5jzVfciOu44ipznXgJVdu1DjE1BVVbsK0KyoOqJuTDmP3NbDGHoalxpUfRis_newNfL21D43Pfu_gT8LrUBxBDLtuX5I8xjXx_y_8BfcLp5m</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1708898175</pqid></control><display><type>article</type><title>Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time?</title><source>MEDLINE</source><source>SAGE Journals Online</source><creator>Cengic, Ismet ; Tureli, Derya ; Ozden, Ferhat ; Bugdayci, Onur ; Aydin, Hilal ; Aribal, Erkin</creator><creatorcontrib>Cengic, Ismet ; Tureli, Derya ; Ozden, Ferhat ; Bugdayci, Onur ; Aydin, Hilal ; Aribal, Erkin</creatorcontrib><description>Background
A fine needle aspiration biopsy (FNAB) of thyroid nodules – the least invasive and most accurate method used to investigate malignant lesions – may yield non-diagnostic specimens even under ultrasonographic guidance.
Purpose
To evaluate the effects of thyroid nodule volume and extent of cystic degeneration on both the non-diagnostic specimen ratio as well as cytopathologist’s definitive cytological diagnosis time.
Material and Methods
In this single center study, FNAB was performed on 505 patients with single thyroid nodules greater than 10 mm. Nodule volume was calculated prior to FNAB and cystic degeneration ratio was recorded. All biopsies were performed by a single radiologist who also prepared specimen slides. Specimen adequacy and final diagnosis were made in the pathology laboratory by a single-blinded cytopathologist based on the Bethesda system. Definitive cytological diagnosis time was recorded upon reaching a definitive diagnosis.
Results
The specimen adequacy ratio was 85.3%. The mean nodule volume of adequate specimens was larger than those of non-diagnostic samples (6.00 mL vs. 3.05 mL; P = 0.001). There was no correlation between nodule volume and cytopathologist’s definitive cytological diagnosis time (r = 0.042). Biopsy of predominantly solid nodules yielded better specimen adequacy ratios compared to predominantly cystic nodules (87.8% vs. 75.3%; P = 0.028). Definitive cytological diagnosis times were longer in predominantly cystic nodules compared to predominantly solid nodules (376 s vs. 294 s; P = 0.019).
Conclusion
Predominantly cystic nodules are likely to benefit from repeated nodular sampling until the specimen is declared adequate by an on-site cytopathologist. If a cytopathologist is not available, obtaining more specimens per nodule may achieve desired adequacy ratios.</description><identifier>ISSN: 0284-1851</identifier><identifier>EISSN: 1600-0455</identifier><identifier>DOI: 10.1177/0284185114554825</identifier><identifier>PMID: 25344502</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Adequacy ; Adolescent ; Adult ; Aged ; Biopsy, Fine-Needle ; Degeneration ; Diagnosis ; Female ; Humans ; Male ; Mathematical analysis ; Middle Aged ; Needles ; Nodules ; Pathology ; Sampling ; Thyroid Neoplasms - pathology ; Thyroid Nodule - pathology ; Ultrasonography, Interventional</subject><ispartof>Acta radiologica (1987), 2015-10, Vol.56 (10), p.1203-1208</ispartof><rights>The Foundation Acta Radiologica 2014</rights><rights>The Foundation Acta Radiologica 2014.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-f077a7667ca45a661bea2071a170b91d5ad5fa8670227014b256161a735c7a923</citedby><cites>FETCH-LOGICAL-c370t-f077a7667ca45a661bea2071a170b91d5ad5fa8670227014b256161a735c7a923</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/0284185114554825$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/0284185114554825$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21799,27903,27904,43600,43601</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25344502$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cengic, Ismet</creatorcontrib><creatorcontrib>Tureli, Derya</creatorcontrib><creatorcontrib>Ozden, Ferhat</creatorcontrib><creatorcontrib>Bugdayci, Onur</creatorcontrib><creatorcontrib>Aydin, Hilal</creatorcontrib><creatorcontrib>Aribal, Erkin</creatorcontrib><title>Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time?</title><title>Acta radiologica (1987)</title><addtitle>Acta Radiol</addtitle><description>Background
A fine needle aspiration biopsy (FNAB) of thyroid nodules – the least invasive and most accurate method used to investigate malignant lesions – may yield non-diagnostic specimens even under ultrasonographic guidance.
Purpose
To evaluate the effects of thyroid nodule volume and extent of cystic degeneration on both the non-diagnostic specimen ratio as well as cytopathologist’s definitive cytological diagnosis time.
Material and Methods
In this single center study, FNAB was performed on 505 patients with single thyroid nodules greater than 10 mm. Nodule volume was calculated prior to FNAB and cystic degeneration ratio was recorded. All biopsies were performed by a single radiologist who also prepared specimen slides. Specimen adequacy and final diagnosis were made in the pathology laboratory by a single-blinded cytopathologist based on the Bethesda system. Definitive cytological diagnosis time was recorded upon reaching a definitive diagnosis.
Results
The specimen adequacy ratio was 85.3%. The mean nodule volume of adequate specimens was larger than those of non-diagnostic samples (6.00 mL vs. 3.05 mL; P = 0.001). There was no correlation between nodule volume and cytopathologist’s definitive cytological diagnosis time (r = 0.042). Biopsy of predominantly solid nodules yielded better specimen adequacy ratios compared to predominantly cystic nodules (87.8% vs. 75.3%; P = 0.028). Definitive cytological diagnosis times were longer in predominantly cystic nodules compared to predominantly solid nodules (376 s vs. 294 s; P = 0.019).
Conclusion
Predominantly cystic nodules are likely to benefit from repeated nodular sampling until the specimen is declared adequate by an on-site cytopathologist. If a cytopathologist is not available, obtaining more specimens per nodule may achieve desired adequacy ratios.</description><subject>Adequacy</subject><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Biopsy, Fine-Needle</subject><subject>Degeneration</subject><subject>Diagnosis</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Mathematical analysis</subject><subject>Middle Aged</subject><subject>Needles</subject><subject>Nodules</subject><subject>Pathology</subject><subject>Sampling</subject><subject>Thyroid Neoplasms - pathology</subject><subject>Thyroid Nodule - pathology</subject><subject>Ultrasonography, Interventional</subject><issn>0284-1851</issn><issn>1600-0455</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkUFv1DAQhS0EotvCnRPykUvA4409WS4IVS1FqtRLOUcTe7K4Suw0TpDyJ_jNZNmFAxJST0-j9713mCfEG1DvARA_KF2VUBmA0piy0uaZ2IBVqlDr_VxsDnZx8M_Eec4PSoFGAy_FmTbbsjRKb8TP--_LmIKXbYgsI7PvWFIewkhTSFE2IQ15-Sh9kjH5eTV_pG7uVyZ66ZY8BSc97znyKfBbJLUtu0nmgV3oOUry_DiTW06xKXVpHxx10gfax5RDltMKfnolXrTUZX590gvx7frq_vKmuL378vXy823htqimolWIhNaio9KQtdAwaYVAgKrZgTfkTUuVRaU1KigbbSxYINwah7TT2wvx7tg7jOlx5jzVfciOu44ipznXgJVdu1DjE1BVVbsK0KyoOqJuTDmP3NbDGHoalxpUfRis_newNfL21D43Pfu_gT8LrUBxBDLtuX5I8xjXx_y_8BfcLp5m</recordid><startdate>201510</startdate><enddate>201510</enddate><creator>Cengic, Ismet</creator><creator>Tureli, Derya</creator><creator>Ozden, Ferhat</creator><creator>Bugdayci, Onur</creator><creator>Aydin, Hilal</creator><creator>Aribal, Erkin</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>201510</creationdate><title>Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time?</title><author>Cengic, Ismet ; Tureli, Derya ; Ozden, Ferhat ; Bugdayci, Onur ; Aydin, Hilal ; Aribal, Erkin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-f077a7667ca45a661bea2071a170b91d5ad5fa8670227014b256161a735c7a923</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adequacy</topic><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Biopsy, Fine-Needle</topic><topic>Degeneration</topic><topic>Diagnosis</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Mathematical analysis</topic><topic>Middle Aged</topic><topic>Needles</topic><topic>Nodules</topic><topic>Pathology</topic><topic>Sampling</topic><topic>Thyroid Neoplasms - pathology</topic><topic>Thyroid Nodule - pathology</topic><topic>Ultrasonography, Interventional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cengic, Ismet</creatorcontrib><creatorcontrib>Tureli, Derya</creatorcontrib><creatorcontrib>Ozden, Ferhat</creatorcontrib><creatorcontrib>Bugdayci, Onur</creatorcontrib><creatorcontrib>Aydin, Hilal</creatorcontrib><creatorcontrib>Aribal, Erkin</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Acta radiologica (1987)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cengic, Ismet</au><au>Tureli, Derya</au><au>Ozden, Ferhat</au><au>Bugdayci, Onur</au><au>Aydin, Hilal</au><au>Aribal, Erkin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time?</atitle><jtitle>Acta radiologica (1987)</jtitle><addtitle>Acta Radiol</addtitle><date>2015-10</date><risdate>2015</risdate><volume>56</volume><issue>10</issue><spage>1203</spage><epage>1208</epage><pages>1203-1208</pages><issn>0284-1851</issn><eissn>1600-0455</eissn><abstract>Background
A fine needle aspiration biopsy (FNAB) of thyroid nodules – the least invasive and most accurate method used to investigate malignant lesions – may yield non-diagnostic specimens even under ultrasonographic guidance.
Purpose
To evaluate the effects of thyroid nodule volume and extent of cystic degeneration on both the non-diagnostic specimen ratio as well as cytopathologist’s definitive cytological diagnosis time.
Material and Methods
In this single center study, FNAB was performed on 505 patients with single thyroid nodules greater than 10 mm. Nodule volume was calculated prior to FNAB and cystic degeneration ratio was recorded. All biopsies were performed by a single radiologist who also prepared specimen slides. Specimen adequacy and final diagnosis were made in the pathology laboratory by a single-blinded cytopathologist based on the Bethesda system. Definitive cytological diagnosis time was recorded upon reaching a definitive diagnosis.
Results
The specimen adequacy ratio was 85.3%. The mean nodule volume of adequate specimens was larger than those of non-diagnostic samples (6.00 mL vs. 3.05 mL; P = 0.001). There was no correlation between nodule volume and cytopathologist’s definitive cytological diagnosis time (r = 0.042). Biopsy of predominantly solid nodules yielded better specimen adequacy ratios compared to predominantly cystic nodules (87.8% vs. 75.3%; P = 0.028). Definitive cytological diagnosis times were longer in predominantly cystic nodules compared to predominantly solid nodules (376 s vs. 294 s; P = 0.019).
Conclusion
Predominantly cystic nodules are likely to benefit from repeated nodular sampling until the specimen is declared adequate by an on-site cytopathologist. If a cytopathologist is not available, obtaining more specimens per nodule may achieve desired adequacy ratios.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>25344502</pmid><doi>10.1177/0284185114554825</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0284-1851 |
ispartof | Acta radiologica (1987), 2015-10, Vol.56 (10), p.1203-1208 |
issn | 0284-1851 1600-0455 |
language | eng |
recordid | cdi_proquest_miscellaneous_1786170727 |
source | MEDLINE; SAGE Journals Online |
subjects | Adequacy Adolescent Adult Aged Biopsy, Fine-Needle Degeneration Diagnosis Female Humans Male Mathematical analysis Middle Aged Needles Nodules Pathology Sampling Thyroid Neoplasms - pathology Thyroid Nodule - pathology Ultrasonography, Interventional |
title | Thyroid fine needle aspiration biopsy: do nodule volume and cystic degeneration ratio affect specimen adequacy and cytological diagnosis time? |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T00%3A49%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Thyroid%20fine%20needle%20aspiration%20biopsy:%20do%20nodule%20volume%20and%20cystic%20degeneration%20ratio%20affect%20specimen%20adequacy%20and%20cytological%20diagnosis%20time?&rft.jtitle=Acta%20radiologica%20(1987)&rft.au=Cengic,%20Ismet&rft.date=2015-10&rft.volume=56&rft.issue=10&rft.spage=1203&rft.epage=1208&rft.pages=1203-1208&rft.issn=0284-1851&rft.eissn=1600-0455&rft_id=info:doi/10.1177/0284185114554825&rft_dat=%3Cproquest_cross%3E1708898175%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1708898175&rft_id=info:pmid/25344502&rft_sage_id=10.1177_0284185114554825&rfr_iscdi=true |