Long-Term Mechanical Circulatory Support in Pediatric Patients
This retrospective study reviews our results regarding the long‐term support in pediatric patients using two ventricular assist systems between January 2008 and April 2014. We implanted the Berlin Heart EXCOR in 29 patients (median age 3.4 years [interquartile range (IQR) 0.2–16.5], median weight 13...
Gespeichert in:
Veröffentlicht in: | Artificial organs 2016-03, Vol.40 (3), p.225-232 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This retrospective study reviews our results regarding the long‐term support in pediatric patients using two ventricular assist systems between January 2008 and April 2014. We implanted the Berlin Heart EXCOR in 29 patients (median age 3.4 years [interquartile range (IQR) 0.2–16.5], median weight 13 kg [IQR 4.2–67.2]). Twenty‐two patients (75.8%) received a left ventricular assist device. Three patients (10.3%) had single‐ventricle physiology. One patient (3.4%) had mechanical mitral valve prosthesis. The HeartWare System was implanted in nine patients. The median age was 15.6 years (IQR 12.2–17.9), and the median weight was 54.9 kg (IQR 27.7–66). In the Berlin Heart group, the median support time was 65 days (IQR 4–619), with 3647 days of cardiac support. Nineteen patients (65.5%) were transplanted, six patients (20.7%) recovered, one patient (3.4%) is on support, and three patients (10.3%) died on support. Survival rate was 89.7%. Fourteen blood pumps had been exchanged. Four patients (13.8%) had local signs of infection, and three patients (10.3%) had neurological complications. In the HeartWare group, the median support time was 180 days (IQR 1–1124), with 2839 days of cardiac support. Four patients (44.4%) had local signs of infection, and three (33.3%) had neurological complications. Eight patients (88.9%) have been transplanted, and one patient (11.1%) died on support. Survival rate was 88.9%. Excellent survival is possible after long‐term mechanical circulatory support in patients with two‐ and single‐ventricle physiology with a low rate of adverse events. |
---|---|
ISSN: | 0160-564X 1525-1594 |
DOI: | 10.1111/aor.12552 |