Reproducibility of 3D kinematics and surface electromyography measurements of mastication

Abstract The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiology & behavior 2016-03, Vol.155, p.112-121
Hauptverfasser: Remijn, Lianne, Groen, Brenda E, Speyer, Renée, van Limbeek, Jacques, Nijhuis-van der Sanden, Maria W.G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 121
container_issue
container_start_page 112
container_title Physiology & behavior
container_volume 155
creator Remijn, Lianne
Groen, Brenda E
Speyer, Renée
van Limbeek, Jacques
Nijhuis-van der Sanden, Maria W.G
description Abstract The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland–Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for ‘ time-to-swallow ’, ‘ time-to-transport ’ and ‘number of chewing cycles ’, but ranged from 31.5% to 57.0% for ‘ change of chewing side ’. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables.
doi_str_mv 10.1016/j.physbeh.2015.11.018
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1768583776</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0031938415301797</els_id><sourcerecordid>1760883090</sourcerecordid><originalsourceid>FETCH-LOGICAL-c519t-63ba2f8ba07061044a089235f9e64a73507c6072b0288018864ecb6905c6e8fb3</originalsourceid><addsrcrecordid>eNqNUk1v1DAUtBCILoWfAMqRS8J7cWI7FxAqn1KlSgUkOFmO80K9TeLFTpDy73G0C4deii8-eOaNZ-Yx9hyhQEDxal8cbtbY0k1RAtYFYgGoHrAdKsnzGuT3h2wHwDFvuKrO2JMY95AOr_hjdlYKgbICvmM_rukQfLdY17rBzWvm-4y_y27dRKOZnY2ZmbosLqE3ljIayM7Bj6v_GUzSz0Yy6Y1Gmua4UUcTEykR_fSUPerNEOnZ6T5n3z68_3rxKb-8-vj54u1lbmts5lzw1pS9ag1IEAhVZUA1Ja_7hkRlJE9WrABZtlAqlSwqUZFtRQO1FaT6lp-zl8e5ycevheKsRxctDYOZyC9RoxSqVlxK8T9QUIpDAwlaH6E2-BgD9foQ3GjCqhH0VoDe61MBeitAI-r0u8R7cZJY2pG6f6y_iSfAmyOAUia_HQUdraPJUudCCld33t0r8frOBDu4KaU-3NJKce-XMKXANepYatBfti3YlgBrDigbyf8AyuauUA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1760883090</pqid></control><display><type>article</type><title>Reproducibility of 3D kinematics and surface electromyography measurements of mastication</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Remijn, Lianne ; Groen, Brenda E ; Speyer, Renée ; van Limbeek, Jacques ; Nijhuis-van der Sanden, Maria W.G</creator><creatorcontrib>Remijn, Lianne ; Groen, Brenda E ; Speyer, Renée ; van Limbeek, Jacques ; Nijhuis-van der Sanden, Maria W.G</creatorcontrib><description>Abstract The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland–Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for ‘ time-to-swallow ’, ‘ time-to-transport ’ and ‘number of chewing cycles ’, but ranged from 31.5% to 57.0% for ‘ change of chewing side ’. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables.</description><identifier>ISSN: 0031-9384</identifier><identifier>EISSN: 1873-507X</identifier><identifier>DOI: 10.1016/j.physbeh.2015.11.018</identifier><identifier>PMID: 26617403</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Adult ; Biomechanical Phenomena ; Chewing movement ; Electromyography - methods ; Female ; Food ; Humans ; Imaging, Three-Dimensional - methods ; Jaw - physiology ; Kinematics ; Male ; Mastication ; Mastication - physiology ; Masticatory Muscles - physiology ; Psychiatry ; Reproducibility of Results ; sEMG ; Textures</subject><ispartof>Physiology &amp; behavior, 2016-03, Vol.155, p.112-121</ispartof><rights>Elsevier Inc.</rights><rights>2015 Elsevier Inc.</rights><rights>Copyright © 2015 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c519t-63ba2f8ba07061044a089235f9e64a73507c6072b0288018864ecb6905c6e8fb3</citedby><cites>FETCH-LOGICAL-c519t-63ba2f8ba07061044a089235f9e64a73507c6072b0288018864ecb6905c6e8fb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0031938415301797$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26617403$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Remijn, Lianne</creatorcontrib><creatorcontrib>Groen, Brenda E</creatorcontrib><creatorcontrib>Speyer, Renée</creatorcontrib><creatorcontrib>van Limbeek, Jacques</creatorcontrib><creatorcontrib>Nijhuis-van der Sanden, Maria W.G</creatorcontrib><title>Reproducibility of 3D kinematics and surface electromyography measurements of mastication</title><title>Physiology &amp; behavior</title><addtitle>Physiol Behav</addtitle><description>Abstract The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland–Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for ‘ time-to-swallow ’, ‘ time-to-transport ’ and ‘number of chewing cycles ’, but ranged from 31.5% to 57.0% for ‘ change of chewing side ’. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables.</description><subject>Adult</subject><subject>Biomechanical Phenomena</subject><subject>Chewing movement</subject><subject>Electromyography - methods</subject><subject>Female</subject><subject>Food</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional - methods</subject><subject>Jaw - physiology</subject><subject>Kinematics</subject><subject>Male</subject><subject>Mastication</subject><subject>Mastication - physiology</subject><subject>Masticatory Muscles - physiology</subject><subject>Psychiatry</subject><subject>Reproducibility of Results</subject><subject>sEMG</subject><subject>Textures</subject><issn>0031-9384</issn><issn>1873-507X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNUk1v1DAUtBCILoWfAMqRS8J7cWI7FxAqn1KlSgUkOFmO80K9TeLFTpDy73G0C4deii8-eOaNZ-Yx9hyhQEDxal8cbtbY0k1RAtYFYgGoHrAdKsnzGuT3h2wHwDFvuKrO2JMY95AOr_hjdlYKgbICvmM_rukQfLdY17rBzWvm-4y_y27dRKOZnY2ZmbosLqE3ljIayM7Bj6v_GUzSz0Yy6Y1Gmua4UUcTEykR_fSUPerNEOnZ6T5n3z68_3rxKb-8-vj54u1lbmts5lzw1pS9ag1IEAhVZUA1Ja_7hkRlJE9WrABZtlAqlSwqUZFtRQO1FaT6lp-zl8e5ycevheKsRxctDYOZyC9RoxSqVlxK8T9QUIpDAwlaH6E2-BgD9foQ3GjCqhH0VoDe61MBeitAI-r0u8R7cZJY2pG6f6y_iSfAmyOAUia_HQUdraPJUudCCld33t0r8frOBDu4KaU-3NJKce-XMKXANepYatBfti3YlgBrDigbyf8AyuauUA</recordid><startdate>20160301</startdate><enddate>20160301</enddate><creator>Remijn, Lianne</creator><creator>Groen, Brenda E</creator><creator>Speyer, Renée</creator><creator>van Limbeek, Jacques</creator><creator>Nijhuis-van der Sanden, Maria W.G</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7QG</scope><scope>7TK</scope></search><sort><creationdate>20160301</creationdate><title>Reproducibility of 3D kinematics and surface electromyography measurements of mastication</title><author>Remijn, Lianne ; Groen, Brenda E ; Speyer, Renée ; van Limbeek, Jacques ; Nijhuis-van der Sanden, Maria W.G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c519t-63ba2f8ba07061044a089235f9e64a73507c6072b0288018864ecb6905c6e8fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adult</topic><topic>Biomechanical Phenomena</topic><topic>Chewing movement</topic><topic>Electromyography - methods</topic><topic>Female</topic><topic>Food</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional - methods</topic><topic>Jaw - physiology</topic><topic>Kinematics</topic><topic>Male</topic><topic>Mastication</topic><topic>Mastication - physiology</topic><topic>Masticatory Muscles - physiology</topic><topic>Psychiatry</topic><topic>Reproducibility of Results</topic><topic>sEMG</topic><topic>Textures</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Remijn, Lianne</creatorcontrib><creatorcontrib>Groen, Brenda E</creatorcontrib><creatorcontrib>Speyer, Renée</creatorcontrib><creatorcontrib>van Limbeek, Jacques</creatorcontrib><creatorcontrib>Nijhuis-van der Sanden, Maria W.G</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Animal Behavior Abstracts</collection><collection>Neurosciences Abstracts</collection><jtitle>Physiology &amp; behavior</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Remijn, Lianne</au><au>Groen, Brenda E</au><au>Speyer, Renée</au><au>van Limbeek, Jacques</au><au>Nijhuis-van der Sanden, Maria W.G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reproducibility of 3D kinematics and surface electromyography measurements of mastication</atitle><jtitle>Physiology &amp; behavior</jtitle><addtitle>Physiol Behav</addtitle><date>2016-03-01</date><risdate>2016</risdate><volume>155</volume><spage>112</spage><epage>121</epage><pages>112-121</pages><issn>0031-9384</issn><eissn>1873-507X</eissn><abstract>Abstract The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland–Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for ‘ time-to-swallow ’, ‘ time-to-transport ’ and ‘number of chewing cycles ’, but ranged from 31.5% to 57.0% for ‘ change of chewing side ’. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>26617403</pmid><doi>10.1016/j.physbeh.2015.11.018</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9384
ispartof Physiology & behavior, 2016-03, Vol.155, p.112-121
issn 0031-9384
1873-507X
language eng
recordid cdi_proquest_miscellaneous_1768583776
source MEDLINE; Elsevier ScienceDirect Journals
subjects Adult
Biomechanical Phenomena
Chewing movement
Electromyography - methods
Female
Food
Humans
Imaging, Three-Dimensional - methods
Jaw - physiology
Kinematics
Male
Mastication
Mastication - physiology
Masticatory Muscles - physiology
Psychiatry
Reproducibility of Results
sEMG
Textures
title Reproducibility of 3D kinematics and surface electromyography measurements of mastication
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T21%3A49%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reproducibility%20of%203D%20kinematics%20and%20surface%20electromyography%20measurements%20of%20mastication&rft.jtitle=Physiology%20&%20behavior&rft.au=Remijn,%20Lianne&rft.date=2016-03-01&rft.volume=155&rft.spage=112&rft.epage=121&rft.pages=112-121&rft.issn=0031-9384&rft.eissn=1873-507X&rft_id=info:doi/10.1016/j.physbeh.2015.11.018&rft_dat=%3Cproquest_cross%3E1760883090%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1760883090&rft_id=info:pmid/26617403&rft_els_id=S0031938415301797&rfr_iscdi=true