Regulator Circuit Transformer Voltage-Second Product Analysis

With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2014-06, Vol.529 (Mechanical Automation and Materials Engineering II), p.501-505
Hauptverfasser: Zhang, Chi, He, Ming Zhi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 505
container_issue Mechanical Automation and Materials Engineering II
container_start_page 501
container_title Applied Mechanics and Materials
container_volume 529
creator Zhang, Chi
He, Ming Zhi
description With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the calculation of the primary current when thyristor turns off in three-phase power regulator circuit with transformer load, the impact of the thyristors turn-off order on the transformer primary current voltage-second product is analysised, and through simulation the exactness is verified.
doi_str_mv 10.4028/www.scientific.net/AMM.529.501
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1762090840</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3827072111</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2431-1b04b26262fb224e5070d882d12b6a48dcdee9a86fd2cba211b4aa3803de12503</originalsourceid><addsrcrecordid>eNqNkMtKxDAUQIMP8DX_UBDETTs3j7bpQnEYfIGi6Og2pEk6VjqNJimDf2_GERRXksVd5HDu5SB0hCFjQPh4uVxmXrWmD23Tqqw3YTy5vc1yUmU54A20i4uCpCXjZBONqpJToJzmUDG89fUHaUVpsYP2vH8FKBhmfBedPJj50MlgXTJtnRrakMyc7H1j3cK45Nl2Qc5N-miU7XVy76weVEgmvew-fOsP0HYjO29G33MfPV2cz6ZX6c3d5fV0cpMqwihOcQ2sJkV8TU0IMzmUoDknGpO6kIxrpY2pJC8aTVQtCcY1k5JyoNpgkgPdR8dr75uz74PxQSxar0zXyd7YwQtcFgQq4GyFHv5BX-3g4r0rClcYCCNlpE7XlHLWe2ca8ebahXQfAoNY1RaxtvipLWJtEWuLWFvE2lFwthaEVa1g1MuvPf9TfAIPDI2Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1719102427</pqid></control><display><type>article</type><title>Regulator Circuit Transformer Voltage-Second Product Analysis</title><source>Scientific.net Journals</source><creator>Zhang, Chi ; He, Ming Zhi</creator><creatorcontrib>Zhang, Chi ; He, Ming Zhi</creatorcontrib><description>With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the calculation of the primary current when thyristor turns off in three-phase power regulator circuit with transformer load, the impact of the thyristors turn-off order on the transformer primary current voltage-second product is analysised, and through simulation the exactness is verified.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783038350941</identifier><identifier>ISBN: 303835094X</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.529.501</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Circuits ; Computational efficiency ; Electronics ; Mathematical analysis ; Power regulators ; Regulators ; Thyristors ; Transformers</subject><ispartof>Applied Mechanics and Materials, 2014-06, Vol.529 (Mechanical Automation and Materials Engineering II), p.501-505</ispartof><rights>2014 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Jun 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/3172?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>He, Ming Zhi</creatorcontrib><title>Regulator Circuit Transformer Voltage-Second Product Analysis</title><title>Applied Mechanics and Materials</title><description>With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the calculation of the primary current when thyristor turns off in three-phase power regulator circuit with transformer load, the impact of the thyristors turn-off order on the transformer primary current voltage-second product is analysised, and through simulation the exactness is verified.</description><subject>Circuits</subject><subject>Computational efficiency</subject><subject>Electronics</subject><subject>Mathematical analysis</subject><subject>Power regulators</subject><subject>Regulators</subject><subject>Thyristors</subject><subject>Transformers</subject><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783038350941</isbn><isbn>303835094X</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkMtKxDAUQIMP8DX_UBDETTs3j7bpQnEYfIGi6Og2pEk6VjqNJimDf2_GERRXksVd5HDu5SB0hCFjQPh4uVxmXrWmD23Tqqw3YTy5vc1yUmU54A20i4uCpCXjZBONqpJToJzmUDG89fUHaUVpsYP2vH8FKBhmfBedPJj50MlgXTJtnRrakMyc7H1j3cK45Nl2Qc5N-miU7XVy76weVEgmvew-fOsP0HYjO29G33MfPV2cz6ZX6c3d5fV0cpMqwihOcQ2sJkV8TU0IMzmUoDknGpO6kIxrpY2pJC8aTVQtCcY1k5JyoNpgkgPdR8dr75uz74PxQSxar0zXyd7YwQtcFgQq4GyFHv5BX-3g4r0rClcYCCNlpE7XlHLWe2ca8ebahXQfAoNY1RaxtvipLWJtEWuLWFvE2lFwthaEVa1g1MuvPf9TfAIPDI2Y</recordid><startdate>20140601</startdate><enddate>20140601</enddate><creator>Zhang, Chi</creator><creator>He, Ming Zhi</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20140601</creationdate><title>Regulator Circuit Transformer Voltage-Second Product Analysis</title><author>Zhang, Chi ; He, Ming Zhi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2431-1b04b26262fb224e5070d882d12b6a48dcdee9a86fd2cba211b4aa3803de12503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Circuits</topic><topic>Computational efficiency</topic><topic>Electronics</topic><topic>Mathematical analysis</topic><topic>Power regulators</topic><topic>Regulators</topic><topic>Thyristors</topic><topic>Transformers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>He, Ming Zhi</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Chi</au><au>He, Ming Zhi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Regulator Circuit Transformer Voltage-Second Product Analysis</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2014-06-01</date><risdate>2014</risdate><volume>529</volume><issue>Mechanical Automation and Materials Engineering II</issue><spage>501</spage><epage>505</epage><pages>501-505</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783038350941</isbn><isbn>303835094X</isbn><abstract>With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the calculation of the primary current when thyristor turns off in three-phase power regulator circuit with transformer load, the impact of the thyristors turn-off order on the transformer primary current voltage-second product is analysised, and through simulation the exactness is verified.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.529.501</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1660-9336
ispartof Applied Mechanics and Materials, 2014-06, Vol.529 (Mechanical Automation and Materials Engineering II), p.501-505
issn 1660-9336
1662-7482
1662-7482
language eng
recordid cdi_proquest_miscellaneous_1762090840
source Scientific.net Journals
subjects Circuits
Computational efficiency
Electronics
Mathematical analysis
Power regulators
Regulators
Thyristors
Transformers
title Regulator Circuit Transformer Voltage-Second Product Analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T14%3A16%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Regulator%20Circuit%20Transformer%20Voltage-Second%20Product%20Analysis&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Zhang,%20Chi&rft.date=2014-06-01&rft.volume=529&rft.issue=Mechanical%20Automation%20and%20Materials%20Engineering%20II&rft.spage=501&rft.epage=505&rft.pages=501-505&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783038350941&rft.isbn_list=303835094X&rft_id=info:doi/10.4028/www.scientific.net/AMM.529.501&rft_dat=%3Cproquest_cross%3E3827072111%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1719102427&rft_id=info:pmid/&rfr_iscdi=true