Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists

Background The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate. Objective To assess the efficacy of Endocuff ® , a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is compos...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical endoscopy 2016-01, Vol.30 (1), p.288-295
Hauptverfasser: Pioche, Mathieu, Matsumoto, Minori, Takamaru, Hiroyuki, Sakamoto, Taku, Nakajima, Takeshi, Matsuda, Takahisa, Abe, Seiichiro, Kakugawa, Yasuo, Otake, Yosuke, Saito, Yutaka
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 295
container_issue 1
container_start_page 288
container_title Surgical endoscopy
container_volume 30
creator Pioche, Mathieu
Matsumoto, Minori
Takamaru, Hiroyuki
Sakamoto, Taku
Nakajima, Takeshi
Matsuda, Takahisa
Abe, Seiichiro
Kakugawa, Yasuo
Otake, Yosuke
Saito, Yutaka
description Background The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate. Objective To assess the efficacy of Endocuff ® , a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is composed of a plastic cap surrounded by flexible finger-like projections on the lateral sides of the cap that make holding of the folds during scope withdrawal easier. Design This was a simulated pilot study with one anatomic colorectal model, containing 13 polyps positioned in obvious locations and behind the folds. Thirty-two endoscopists (16 Japanese and 16 foreign visitors) with different levels of experience performed examinations on the model in a randomized order by using Endocuff ® -assisted colonoscopy (EAC) and standard colonoscope (SC). Main outcome measurements To assess the detection rate of polyps and the feasibility of Endocuff ® insertion. Results EAC detected significantly more polyps than SC with 9.9 versus 7.5 mean lesions ( p  = 0.03), respectively, comparing the 16 first colonoscopies in each group. Endocuff ® was useful independent of the level of experience of the participants. After crossover, EAC in second position allowed an additional detection of 1.8 polyps compared with SC ( p  = 0.001). After adjustment on experience, time of detection, and order of colonoscopy, EAC over-detected 1.2 polyps ( p  = 0.0037). The insertion time ( p  = 0.99) was identical. There was no difference in the mean time of polyp detection between EAC and SC groups ( p  = 0.520). Limitations This was not a clinical study. The stiffness of the folds in the colonic model was higher than in the human large bowel. Conclusion EAC was associated with a higher polyp detection rate. Even in such relatively stiff anatomic model, it was easier to spread out the colonic mucosa between the folds using this cap. This study provides an additional argument for the routine application of this easy-to-use accessory to improve polyp detection.
doi_str_mv 10.1007/s00464-015-4208-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1760901025</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1760901025</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-21b50ea6683c3fdd2e8cac91d4cef1751e889635d7510a9c69f81d12d5f8107e3</originalsourceid><addsrcrecordid>eNp9kc2KFTEQhYMoznX0AdxIlm6iSfovcSfD-AMDbnQdMkn10EO606bSA9f3cTsP4ZNZ7R1dCoEqOOd8FDmMvVTyjZJyeItStn0rpOpEq6UR5hE7qLbRQmtlHrODtI0UerDtGXuGeCvJblX3lJ3pzvTKyuHAfl4uMYdtHH_dC484YYXIQ055yRjyeuTTEgp4BORrTseVR6gQ6pQXXnyFd9xznOYt-T1XPMHm6QetWLe4h-9yupuWG-4Xer6SGv7gC0F84nOOkEiJvNHkrlDIRHCSgFj7CXQSPmdPRp8QXjzMc_btw-XXi0_i6svHzxfvr0RoVVuFVtedBN_3pgnNGKMGE3ywKrYBRjV0CoyxfdNFWqW3obejUVHp2NGUAzTn7PWJu5b8fQOsbp4wQEp-gbyhU0MvrVRSd2RVJ2soGbHA6NYyzb4cnZJub8ed2nHUjtvbcYYyrx7w2_UM8V_ibx1k0CcDkrTcQHG3eaMvSfgf6m-JNJ_a</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1760901025</pqid></control><display><type>article</type><title>Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists</title><source>MEDLINE</source><source>SpringerLink (Online service)</source><creator>Pioche, Mathieu ; Matsumoto, Minori ; Takamaru, Hiroyuki ; Sakamoto, Taku ; Nakajima, Takeshi ; Matsuda, Takahisa ; Abe, Seiichiro ; Kakugawa, Yasuo ; Otake, Yosuke ; Saito, Yutaka</creator><creatorcontrib>Pioche, Mathieu ; Matsumoto, Minori ; Takamaru, Hiroyuki ; Sakamoto, Taku ; Nakajima, Takeshi ; Matsuda, Takahisa ; Abe, Seiichiro ; Kakugawa, Yasuo ; Otake, Yosuke ; Saito, Yutaka</creatorcontrib><description>Background The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate. Objective To assess the efficacy of Endocuff ® , a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is composed of a plastic cap surrounded by flexible finger-like projections on the lateral sides of the cap that make holding of the folds during scope withdrawal easier. Design This was a simulated pilot study with one anatomic colorectal model, containing 13 polyps positioned in obvious locations and behind the folds. Thirty-two endoscopists (16 Japanese and 16 foreign visitors) with different levels of experience performed examinations on the model in a randomized order by using Endocuff ® -assisted colonoscopy (EAC) and standard colonoscope (SC). Main outcome measurements To assess the detection rate of polyps and the feasibility of Endocuff ® insertion. Results EAC detected significantly more polyps than SC with 9.9 versus 7.5 mean lesions ( p  = 0.03), respectively, comparing the 16 first colonoscopies in each group. Endocuff ® was useful independent of the level of experience of the participants. After crossover, EAC in second position allowed an additional detection of 1.8 polyps compared with SC ( p  = 0.001). After adjustment on experience, time of detection, and order of colonoscopy, EAC over-detected 1.2 polyps ( p  = 0.0037). The insertion time ( p  = 0.99) was identical. There was no difference in the mean time of polyp detection between EAC and SC groups ( p  = 0.520). Limitations This was not a clinical study. The stiffness of the folds in the colonic model was higher than in the human large bowel. Conclusion EAC was associated with a higher polyp detection rate. Even in such relatively stiff anatomic model, it was easier to spread out the colonic mucosa between the folds using this cap. This study provides an additional argument for the routine application of this easy-to-use accessory to improve polyp detection.</description><identifier>ISSN: 0930-2794</identifier><identifier>EISSN: 1432-2218</identifier><identifier>DOI: 10.1007/s00464-015-4208-8</identifier><identifier>PMID: 25861907</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Abdominal Surgery ; Adult ; Colonic Polyps - diagnosis ; Colonic Polyps - surgery ; Colonoscopes ; Colonoscopy ; Female ; Gastroenterology ; Gynecology ; Hepatology ; Humans ; Male ; Medicine ; Medicine &amp; Public Health ; Middle Aged ; Models, Anatomic ; Pilot Projects ; Proctology ; Prospective Studies ; Random Allocation ; Surgery</subject><ispartof>Surgical endoscopy, 2016-01, Vol.30 (1), p.288-295</ispartof><rights>Springer Science+Business Media New York 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-21b50ea6683c3fdd2e8cac91d4cef1751e889635d7510a9c69f81d12d5f8107e3</citedby><cites>FETCH-LOGICAL-c414t-21b50ea6683c3fdd2e8cac91d4cef1751e889635d7510a9c69f81d12d5f8107e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00464-015-4208-8$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00464-015-4208-8$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25861907$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pioche, Mathieu</creatorcontrib><creatorcontrib>Matsumoto, Minori</creatorcontrib><creatorcontrib>Takamaru, Hiroyuki</creatorcontrib><creatorcontrib>Sakamoto, Taku</creatorcontrib><creatorcontrib>Nakajima, Takeshi</creatorcontrib><creatorcontrib>Matsuda, Takahisa</creatorcontrib><creatorcontrib>Abe, Seiichiro</creatorcontrib><creatorcontrib>Kakugawa, Yasuo</creatorcontrib><creatorcontrib>Otake, Yosuke</creatorcontrib><creatorcontrib>Saito, Yutaka</creatorcontrib><title>Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists</title><title>Surgical endoscopy</title><addtitle>Surg Endosc</addtitle><addtitle>Surg Endosc</addtitle><description>Background The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate. Objective To assess the efficacy of Endocuff ® , a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is composed of a plastic cap surrounded by flexible finger-like projections on the lateral sides of the cap that make holding of the folds during scope withdrawal easier. Design This was a simulated pilot study with one anatomic colorectal model, containing 13 polyps positioned in obvious locations and behind the folds. Thirty-two endoscopists (16 Japanese and 16 foreign visitors) with different levels of experience performed examinations on the model in a randomized order by using Endocuff ® -assisted colonoscopy (EAC) and standard colonoscope (SC). Main outcome measurements To assess the detection rate of polyps and the feasibility of Endocuff ® insertion. Results EAC detected significantly more polyps than SC with 9.9 versus 7.5 mean lesions ( p  = 0.03), respectively, comparing the 16 first colonoscopies in each group. Endocuff ® was useful independent of the level of experience of the participants. After crossover, EAC in second position allowed an additional detection of 1.8 polyps compared with SC ( p  = 0.001). After adjustment on experience, time of detection, and order of colonoscopy, EAC over-detected 1.2 polyps ( p  = 0.0037). The insertion time ( p  = 0.99) was identical. There was no difference in the mean time of polyp detection between EAC and SC groups ( p  = 0.520). Limitations This was not a clinical study. The stiffness of the folds in the colonic model was higher than in the human large bowel. Conclusion EAC was associated with a higher polyp detection rate. Even in such relatively stiff anatomic model, it was easier to spread out the colonic mucosa between the folds using this cap. This study provides an additional argument for the routine application of this easy-to-use accessory to improve polyp detection.</description><subject>Abdominal Surgery</subject><subject>Adult</subject><subject>Colonic Polyps - diagnosis</subject><subject>Colonic Polyps - surgery</subject><subject>Colonoscopes</subject><subject>Colonoscopy</subject><subject>Female</subject><subject>Gastroenterology</subject><subject>Gynecology</subject><subject>Hepatology</subject><subject>Humans</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Middle Aged</subject><subject>Models, Anatomic</subject><subject>Pilot Projects</subject><subject>Proctology</subject><subject>Prospective Studies</subject><subject>Random Allocation</subject><subject>Surgery</subject><issn>0930-2794</issn><issn>1432-2218</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc2KFTEQhYMoznX0AdxIlm6iSfovcSfD-AMDbnQdMkn10EO606bSA9f3cTsP4ZNZ7R1dCoEqOOd8FDmMvVTyjZJyeItStn0rpOpEq6UR5hE7qLbRQmtlHrODtI0UerDtGXuGeCvJblX3lJ3pzvTKyuHAfl4uMYdtHH_dC484YYXIQ055yRjyeuTTEgp4BORrTseVR6gQ6pQXXnyFd9xznOYt-T1XPMHm6QetWLe4h-9yupuWG-4Xer6SGv7gC0F84nOOkEiJvNHkrlDIRHCSgFj7CXQSPmdPRp8QXjzMc_btw-XXi0_i6svHzxfvr0RoVVuFVtedBN_3pgnNGKMGE3ywKrYBRjV0CoyxfdNFWqW3obejUVHp2NGUAzTn7PWJu5b8fQOsbp4wQEp-gbyhU0MvrVRSd2RVJ2soGbHA6NYyzb4cnZJub8ed2nHUjtvbcYYyrx7w2_UM8V_ibx1k0CcDkrTcQHG3eaMvSfgf6m-JNJ_a</recordid><startdate>20160101</startdate><enddate>20160101</enddate><creator>Pioche, Mathieu</creator><creator>Matsumoto, Minori</creator><creator>Takamaru, Hiroyuki</creator><creator>Sakamoto, Taku</creator><creator>Nakajima, Takeshi</creator><creator>Matsuda, Takahisa</creator><creator>Abe, Seiichiro</creator><creator>Kakugawa, Yasuo</creator><creator>Otake, Yosuke</creator><creator>Saito, Yutaka</creator><general>Springer US</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20160101</creationdate><title>Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists</title><author>Pioche, Mathieu ; Matsumoto, Minori ; Takamaru, Hiroyuki ; Sakamoto, Taku ; Nakajima, Takeshi ; Matsuda, Takahisa ; Abe, Seiichiro ; Kakugawa, Yasuo ; Otake, Yosuke ; Saito, Yutaka</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-21b50ea6683c3fdd2e8cac91d4cef1751e889635d7510a9c69f81d12d5f8107e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Abdominal Surgery</topic><topic>Adult</topic><topic>Colonic Polyps - diagnosis</topic><topic>Colonic Polyps - surgery</topic><topic>Colonoscopes</topic><topic>Colonoscopy</topic><topic>Female</topic><topic>Gastroenterology</topic><topic>Gynecology</topic><topic>Hepatology</topic><topic>Humans</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Middle Aged</topic><topic>Models, Anatomic</topic><topic>Pilot Projects</topic><topic>Proctology</topic><topic>Prospective Studies</topic><topic>Random Allocation</topic><topic>Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pioche, Mathieu</creatorcontrib><creatorcontrib>Matsumoto, Minori</creatorcontrib><creatorcontrib>Takamaru, Hiroyuki</creatorcontrib><creatorcontrib>Sakamoto, Taku</creatorcontrib><creatorcontrib>Nakajima, Takeshi</creatorcontrib><creatorcontrib>Matsuda, Takahisa</creatorcontrib><creatorcontrib>Abe, Seiichiro</creatorcontrib><creatorcontrib>Kakugawa, Yasuo</creatorcontrib><creatorcontrib>Otake, Yosuke</creatorcontrib><creatorcontrib>Saito, Yutaka</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Surgical endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pioche, Mathieu</au><au>Matsumoto, Minori</au><au>Takamaru, Hiroyuki</au><au>Sakamoto, Taku</au><au>Nakajima, Takeshi</au><au>Matsuda, Takahisa</au><au>Abe, Seiichiro</au><au>Kakugawa, Yasuo</au><au>Otake, Yosuke</au><au>Saito, Yutaka</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists</atitle><jtitle>Surgical endoscopy</jtitle><stitle>Surg Endosc</stitle><addtitle>Surg Endosc</addtitle><date>2016-01-01</date><risdate>2016</risdate><volume>30</volume><issue>1</issue><spage>288</spage><epage>295</epage><pages>288-295</pages><issn>0930-2794</issn><eissn>1432-2218</eissn><abstract>Background The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate. Objective To assess the efficacy of Endocuff ® , a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is composed of a plastic cap surrounded by flexible finger-like projections on the lateral sides of the cap that make holding of the folds during scope withdrawal easier. Design This was a simulated pilot study with one anatomic colorectal model, containing 13 polyps positioned in obvious locations and behind the folds. Thirty-two endoscopists (16 Japanese and 16 foreign visitors) with different levels of experience performed examinations on the model in a randomized order by using Endocuff ® -assisted colonoscopy (EAC) and standard colonoscope (SC). Main outcome measurements To assess the detection rate of polyps and the feasibility of Endocuff ® insertion. Results EAC detected significantly more polyps than SC with 9.9 versus 7.5 mean lesions ( p  = 0.03), respectively, comparing the 16 first colonoscopies in each group. Endocuff ® was useful independent of the level of experience of the participants. After crossover, EAC in second position allowed an additional detection of 1.8 polyps compared with SC ( p  = 0.001). After adjustment on experience, time of detection, and order of colonoscopy, EAC over-detected 1.2 polyps ( p  = 0.0037). The insertion time ( p  = 0.99) was identical. There was no difference in the mean time of polyp detection between EAC and SC groups ( p  = 0.520). Limitations This was not a clinical study. The stiffness of the folds in the colonic model was higher than in the human large bowel. Conclusion EAC was associated with a higher polyp detection rate. Even in such relatively stiff anatomic model, it was easier to spread out the colonic mucosa between the folds using this cap. This study provides an additional argument for the routine application of this easy-to-use accessory to improve polyp detection.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>25861907</pmid><doi>10.1007/s00464-015-4208-8</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0930-2794
ispartof Surgical endoscopy, 2016-01, Vol.30 (1), p.288-295
issn 0930-2794
1432-2218
language eng
recordid cdi_proquest_miscellaneous_1760901025
source MEDLINE; SpringerLink (Online service)
subjects Abdominal Surgery
Adult
Colonic Polyps - diagnosis
Colonic Polyps - surgery
Colonoscopes
Colonoscopy
Female
Gastroenterology
Gynecology
Hepatology
Humans
Male
Medicine
Medicine & Public Health
Middle Aged
Models, Anatomic
Pilot Projects
Proctology
Prospective Studies
Random Allocation
Surgery
title Endocuff®-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T12%3A19%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endocuff%C2%AE-assisted%20colonoscopy%20increases%20polyp%20detection%20rate:%20a%20simulated%20randomized%20study%20involving%20an%20anatomic%20colorectal%20model%20and%2032%20international%20endoscopists&rft.jtitle=Surgical%20endoscopy&rft.au=Pioche,%20Mathieu&rft.date=2016-01-01&rft.volume=30&rft.issue=1&rft.spage=288&rft.epage=295&rft.pages=288-295&rft.issn=0930-2794&rft.eissn=1432-2218&rft_id=info:doi/10.1007/s00464-015-4208-8&rft_dat=%3Cproquest_cross%3E1760901025%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1760901025&rft_id=info:pmid/25861907&rfr_iscdi=true