Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution

Liquid storage of hematopoietic stem and progenitor cells often is necessary in clinical cell engineering. The interval between cell harvest and transplantation or processing may be as long as 1 or 2 days. We previously developed an infusible-grade solution, STM-Sav, for nonfrozen storage of periphe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cell preservation technology 2003, Vol.1 (1), p.45-51
Hauptverfasser: Schmid, J.L., McCullough, J., Burger, S.R., Hubel, A.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 51
container_issue 1
container_start_page 45
container_title Cell preservation technology
container_volume 1
creator Schmid, J.L.
McCullough, J.
Burger, S.R.
Hubel, A.
description Liquid storage of hematopoietic stem and progenitor cells often is necessary in clinical cell engineering. The interval between cell harvest and transplantation or processing may be as long as 1 or 2 days. We previously developed an infusible-grade solution, STM-Sav, for nonfrozen storage of peripheral blood stem cells. This study addresses the validation of the storage conditions using STM-Sav for the short-term storage of bone marrow. Bone marrow from normal donors was stored in STM-Sav in gas-permeable Cryocyte and plasma transfer bags at 4 degree C and room temperature. Cell viability, number, and morphology, percentage of CD34 super(+) cells, frequency of granulocyte/macrophage colony-forming units (CFU-GM), and solution pH were measured every 24 h for up to 72 h. More than 88% of viable nucleated cell recovery was observed at 72 h of liquid storage. CD34 super(+) cell recoveries were unchanged over the 72-h storage period as well, and the frequency of CFU-GM per 10 super(5) cells was also constant. The regulation of solution pH was improved with storage of the cells at 4 degree C in a plasma transfer bag. These results indicate that STM-Sav can be effective in preserving bone marrow viability over a 72-h period during liquid storage.
doi_str_mv 10.1089/15383440260073284
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17562832</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17562832</sourcerecordid><originalsourceid>FETCH-LOGICAL-c189t-57631b814277857a1db5f98259b4b75f543954314c11be5655e398cea91e04383</originalsourceid><addsrcrecordid>eNplkD9PwzAUxC0EEqXwAdg8MRHw85_YHqGCUqmFIUWCKXLSFxSUxsVOivrtSVXEwnC6G346vXeEXAK7AWbsLShhhJSMp4xpwY08IiNQSicGwB7vszDJALydkrMYPxnjnMl0RN6ffVuGnd8EjBi2uKL3vkW6cCH4b5p1PrgPpHVLs-Uiydz2mrqWztqqj3XRYDINboV0gk3zx2a-6bvat-fkpHJNxItfH5PXx4fl5CmZv0xnk7t5UoKxXaJ0KqAwILnWRmkHq0JV1nBlC1loVSkp7CCQJUCBKlUKhTUlOgvI5PD0mFwdejfBf_UYu3xdx3K4yLXo-5iDVik3gg8gHMAy-BgDVvkm1GsXdjmwfD9i_m9E8QP322KJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17562832</pqid></control><display><type>article</type><title>Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution</title><source>Mary Ann Liebert Online Subscription</source><creator>Schmid, J.L. ; McCullough, J. ; Burger, S.R. ; Hubel, A.</creator><creatorcontrib>Schmid, J.L. ; McCullough, J. ; Burger, S.R. ; Hubel, A.</creatorcontrib><description>Liquid storage of hematopoietic stem and progenitor cells often is necessary in clinical cell engineering. The interval between cell harvest and transplantation or processing may be as long as 1 or 2 days. We previously developed an infusible-grade solution, STM-Sav, for nonfrozen storage of peripheral blood stem cells. This study addresses the validation of the storage conditions using STM-Sav for the short-term storage of bone marrow. Bone marrow from normal donors was stored in STM-Sav in gas-permeable Cryocyte and plasma transfer bags at 4 degree C and room temperature. Cell viability, number, and morphology, percentage of CD34 super(+) cells, frequency of granulocyte/macrophage colony-forming units (CFU-GM), and solution pH were measured every 24 h for up to 72 h. More than 88% of viable nucleated cell recovery was observed at 72 h of liquid storage. CD34 super(+) cell recoveries were unchanged over the 72-h storage period as well, and the frequency of CFU-GM per 10 super(5) cells was also constant. The regulation of solution pH was improved with storage of the cells at 4 degree C in a plasma transfer bag. These results indicate that STM-Sav can be effective in preserving bone marrow viability over a 72-h period during liquid storage.</description><identifier>ISSN: 1538-344X</identifier><identifier>EISSN: 1557-8119</identifier><identifier>DOI: 10.1089/15383440260073284</identifier><language>eng</language><ispartof>Cell preservation technology, 2003, Vol.1 (1), p.45-51</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c189t-57631b814277857a1db5f98259b4b75f543954314c11be5655e398cea91e04383</citedby><cites>FETCH-LOGICAL-c189t-57631b814277857a1db5f98259b4b75f543954314c11be5655e398cea91e04383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,3042,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Schmid, J.L.</creatorcontrib><creatorcontrib>McCullough, J.</creatorcontrib><creatorcontrib>Burger, S.R.</creatorcontrib><creatorcontrib>Hubel, A.</creatorcontrib><title>Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution</title><title>Cell preservation technology</title><description>Liquid storage of hematopoietic stem and progenitor cells often is necessary in clinical cell engineering. The interval between cell harvest and transplantation or processing may be as long as 1 or 2 days. We previously developed an infusible-grade solution, STM-Sav, for nonfrozen storage of peripheral blood stem cells. This study addresses the validation of the storage conditions using STM-Sav for the short-term storage of bone marrow. Bone marrow from normal donors was stored in STM-Sav in gas-permeable Cryocyte and plasma transfer bags at 4 degree C and room temperature. Cell viability, number, and morphology, percentage of CD34 super(+) cells, frequency of granulocyte/macrophage colony-forming units (CFU-GM), and solution pH were measured every 24 h for up to 72 h. More than 88% of viable nucleated cell recovery was observed at 72 h of liquid storage. CD34 super(+) cell recoveries were unchanged over the 72-h storage period as well, and the frequency of CFU-GM per 10 super(5) cells was also constant. The regulation of solution pH was improved with storage of the cells at 4 degree C in a plasma transfer bag. These results indicate that STM-Sav can be effective in preserving bone marrow viability over a 72-h period during liquid storage.</description><issn>1538-344X</issn><issn>1557-8119</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNplkD9PwzAUxC0EEqXwAdg8MRHw85_YHqGCUqmFIUWCKXLSFxSUxsVOivrtSVXEwnC6G346vXeEXAK7AWbsLShhhJSMp4xpwY08IiNQSicGwB7vszDJALydkrMYPxnjnMl0RN6ffVuGnd8EjBi2uKL3vkW6cCH4b5p1PrgPpHVLs-Uiydz2mrqWztqqj3XRYDINboV0gk3zx2a-6bvat-fkpHJNxItfH5PXx4fl5CmZv0xnk7t5UoKxXaJ0KqAwILnWRmkHq0JV1nBlC1loVSkp7CCQJUCBKlUKhTUlOgvI5PD0mFwdejfBf_UYu3xdx3K4yLXo-5iDVik3gg8gHMAy-BgDVvkm1GsXdjmwfD9i_m9E8QP322KJ</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Schmid, J.L.</creator><creator>McCullough, J.</creator><creator>Burger, S.R.</creator><creator>Hubel, A.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>2003</creationdate><title>Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution</title><author>Schmid, J.L. ; McCullough, J. ; Burger, S.R. ; Hubel, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c189t-57631b814277857a1db5f98259b4b75f543954314c11be5655e398cea91e04383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Schmid, J.L.</creatorcontrib><creatorcontrib>McCullough, J.</creatorcontrib><creatorcontrib>Burger, S.R.</creatorcontrib><creatorcontrib>Hubel, A.</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Cell preservation technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schmid, J.L.</au><au>McCullough, J.</au><au>Burger, S.R.</au><au>Hubel, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution</atitle><jtitle>Cell preservation technology</jtitle><date>2003</date><risdate>2003</risdate><volume>1</volume><issue>1</issue><spage>45</spage><epage>51</epage><pages>45-51</pages><issn>1538-344X</issn><eissn>1557-8119</eissn><abstract>Liquid storage of hematopoietic stem and progenitor cells often is necessary in clinical cell engineering. The interval between cell harvest and transplantation or processing may be as long as 1 or 2 days. We previously developed an infusible-grade solution, STM-Sav, for nonfrozen storage of peripheral blood stem cells. This study addresses the validation of the storage conditions using STM-Sav for the short-term storage of bone marrow. Bone marrow from normal donors was stored in STM-Sav in gas-permeable Cryocyte and plasma transfer bags at 4 degree C and room temperature. Cell viability, number, and morphology, percentage of CD34 super(+) cells, frequency of granulocyte/macrophage colony-forming units (CFU-GM), and solution pH were measured every 24 h for up to 72 h. More than 88% of viable nucleated cell recovery was observed at 72 h of liquid storage. CD34 super(+) cell recoveries were unchanged over the 72-h storage period as well, and the frequency of CFU-GM per 10 super(5) cells was also constant. The regulation of solution pH was improved with storage of the cells at 4 degree C in a plasma transfer bag. These results indicate that STM-Sav can be effective in preserving bone marrow viability over a 72-h period during liquid storage.</abstract><doi>10.1089/15383440260073284</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1538-344X
ispartof Cell preservation technology, 2003, Vol.1 (1), p.45-51
issn 1538-344X
1557-8119
language eng
recordid cdi_proquest_miscellaneous_17562832
source Mary Ann Liebert Online Subscription
title Noncryopreserved Bone Marrow Storage in STM-Sav, an Infusible-Grade Cell Storage Solution
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T12%3A35%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Noncryopreserved%20Bone%20Marrow%20Storage%20in%20STM-Sav,%20an%20Infusible-Grade%20Cell%20Storage%20Solution&rft.jtitle=Cell%20preservation%20technology&rft.au=Schmid,%20J.L.&rft.date=2003&rft.volume=1&rft.issue=1&rft.spage=45&rft.epage=51&rft.pages=45-51&rft.issn=1538-344X&rft.eissn=1557-8119&rft_id=info:doi/10.1089/15383440260073284&rft_dat=%3Cproquest_cross%3E17562832%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17562832&rft_id=info:pmid/&rfr_iscdi=true