Accommodating perceptions of risk in performance-based building fire safety code development

Differing perceptions of risk by various stakeholders have long played a role in influencing the development of prescriptive-based building fire safety codes. As performance-based building fire safety codes are developed, differing perceptions of risk will continue to be a significant influence. In...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fire safety journal 2000-04, Vol.34 (3), p.297-309
Hauptverfasser: Wolski, Armin, Dembsey, Nicholas A, Meacham, Brian J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 309
container_issue 3
container_start_page 297
container_title Fire safety journal
container_volume 34
creator Wolski, Armin
Dembsey, Nicholas A
Meacham, Brian J
description Differing perceptions of risk by various stakeholders have long played a role in influencing the development of prescriptive-based building fire safety codes. As performance-based building fire safety codes are developed, differing perceptions of risk will continue to be a significant influence. In this paper, the concepts of revealed preference, risk factors, risk adjustment factors and risk conversion factors are discussed, and two methods to address risk perceptions in a performance-based building fire safety code are introduced. The first method proposes the use of risk factors to classify buildings in terms such as low, medium, and high risk. Each class of building would be assigned a risk adjustment factor. Similar to safety factors, risk adjustment factors would be applied during deterministic building fire safety design to provide an increased level of safety in buildings where the risk perceptions would mandate greater safety. The second method would be used with a probabilistic-based building fire safety design approach, and uses risk factors to develop risk conversion factors (RCFs). In the probabilistic approach, a maximum expected-risk-to-life (ERL) value would be established by the code, with appropriate RCFs being applied to adjust maximum ERL values depending on how the building's fire safety risk is perceived.
doi_str_mv 10.1016/S0379-7112(00)00003-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17539550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0379711200000035</els_id><sourcerecordid>17539550</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-62ff226fa06d0716bc93eb38b55287c65e7f9ad46940198a2365a96d476852e3</originalsourceid><addsrcrecordid>eNqFkEtLxDAQx3tQcH18BKEHET1UJ80maU6yiC8QPLhHIaTJRKJtU5Pugt_ednfRo3MZGP4P5pdlpwSuCBB-_QpUyEIQUl4AXMI4tGB72ez3fJAdpvQBQASAnGVvC2NC2warB9-95z1Gg_3gQ5fy4PLo02fuu-nsQmx1Z7CodUKb1yvf2MnhfMQ8aYfDd26CxdziGpvQt9gNx9m-003Ck90-ypb3d8vbx-L55eHpdvFcGMrFUPDSubLkTgO3IAivjaRY06pmrKyE4QyFk9rOuZwDkZUuKWdacjsXvGIl0qPsfBvbx_C1wjSo1ieDTaM7DKukiGBUMgajkG2FJoaUIjrVR9_q-K0IqAmf2uBTEycFoDb4FBt9Z7sCnYxuXBxB-PRnpkzOqyn-ZivD8de1x6iS8TgysyMjMygb_D9FP25Ohlk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17539550</pqid></control><display><type>article</type><title>Accommodating perceptions of risk in performance-based building fire safety code development</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Wolski, Armin ; Dembsey, Nicholas A ; Meacham, Brian J</creator><creatorcontrib>Wolski, Armin ; Dembsey, Nicholas A ; Meacham, Brian J</creatorcontrib><description>Differing perceptions of risk by various stakeholders have long played a role in influencing the development of prescriptive-based building fire safety codes. As performance-based building fire safety codes are developed, differing perceptions of risk will continue to be a significant influence. In this paper, the concepts of revealed preference, risk factors, risk adjustment factors and risk conversion factors are discussed, and two methods to address risk perceptions in a performance-based building fire safety code are introduced. The first method proposes the use of risk factors to classify buildings in terms such as low, medium, and high risk. Each class of building would be assigned a risk adjustment factor. Similar to safety factors, risk adjustment factors would be applied during deterministic building fire safety design to provide an increased level of safety in buildings where the risk perceptions would mandate greater safety. The second method would be used with a probabilistic-based building fire safety design approach, and uses risk factors to develop risk conversion factors (RCFs). In the probabilistic approach, a maximum expected-risk-to-life (ERL) value would be established by the code, with appropriate RCFs being applied to adjust maximum ERL values depending on how the building's fire safety risk is perceived.</description><identifier>ISSN: 0379-7112</identifier><identifier>DOI: 10.1016/S0379-7112(00)00003-5</identifier><identifier>CODEN: FSJODZ</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; building codes ; Building technical equipments ; Buildings ; Buildings. Public works ; Exact sciences and technology ; Fire protection ; Fire safety. Legislation</subject><ispartof>Fire safety journal, 2000-04, Vol.34 (3), p.297-309</ispartof><rights>2000 Elsevier Science B.V.</rights><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-62ff226fa06d0716bc93eb38b55287c65e7f9ad46940198a2365a96d476852e3</citedby><cites>FETCH-LOGICAL-c367t-62ff226fa06d0716bc93eb38b55287c65e7f9ad46940198a2365a96d476852e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0379-7112(00)00003-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,27907,27908,45978</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1359480$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Wolski, Armin</creatorcontrib><creatorcontrib>Dembsey, Nicholas A</creatorcontrib><creatorcontrib>Meacham, Brian J</creatorcontrib><title>Accommodating perceptions of risk in performance-based building fire safety code development</title><title>Fire safety journal</title><description>Differing perceptions of risk by various stakeholders have long played a role in influencing the development of prescriptive-based building fire safety codes. As performance-based building fire safety codes are developed, differing perceptions of risk will continue to be a significant influence. In this paper, the concepts of revealed preference, risk factors, risk adjustment factors and risk conversion factors are discussed, and two methods to address risk perceptions in a performance-based building fire safety code are introduced. The first method proposes the use of risk factors to classify buildings in terms such as low, medium, and high risk. Each class of building would be assigned a risk adjustment factor. Similar to safety factors, risk adjustment factors would be applied during deterministic building fire safety design to provide an increased level of safety in buildings where the risk perceptions would mandate greater safety. The second method would be used with a probabilistic-based building fire safety design approach, and uses risk factors to develop risk conversion factors (RCFs). In the probabilistic approach, a maximum expected-risk-to-life (ERL) value would be established by the code, with appropriate RCFs being applied to adjust maximum ERL values depending on how the building's fire safety risk is perceived.</description><subject>Applied sciences</subject><subject>building codes</subject><subject>Building technical equipments</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Exact sciences and technology</subject><subject>Fire protection</subject><subject>Fire safety. Legislation</subject><issn>0379-7112</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLxDAQx3tQcH18BKEHET1UJ80maU6yiC8QPLhHIaTJRKJtU5Pugt_ednfRo3MZGP4P5pdlpwSuCBB-_QpUyEIQUl4AXMI4tGB72ez3fJAdpvQBQASAnGVvC2NC2warB9-95z1Gg_3gQ5fy4PLo02fuu-nsQmx1Z7CodUKb1yvf2MnhfMQ8aYfDd26CxdziGpvQt9gNx9m-003Ck90-ypb3d8vbx-L55eHpdvFcGMrFUPDSubLkTgO3IAivjaRY06pmrKyE4QyFk9rOuZwDkZUuKWdacjsXvGIl0qPsfBvbx_C1wjSo1ieDTaM7DKukiGBUMgajkG2FJoaUIjrVR9_q-K0IqAmf2uBTEycFoDb4FBt9Z7sCnYxuXBxB-PRnpkzOqyn-ZivD8de1x6iS8TgysyMjMygb_D9FP25Ohlk</recordid><startdate>20000401</startdate><enddate>20000401</enddate><creator>Wolski, Armin</creator><creator>Dembsey, Nicholas A</creator><creator>Meacham, Brian J</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U1</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>20000401</creationdate><title>Accommodating perceptions of risk in performance-based building fire safety code development</title><author>Wolski, Armin ; Dembsey, Nicholas A ; Meacham, Brian J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-62ff226fa06d0716bc93eb38b55287c65e7f9ad46940198a2365a96d476852e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Applied sciences</topic><topic>building codes</topic><topic>Building technical equipments</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Exact sciences and technology</topic><topic>Fire protection</topic><topic>Fire safety. Legislation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wolski, Armin</creatorcontrib><creatorcontrib>Dembsey, Nicholas A</creatorcontrib><creatorcontrib>Meacham, Brian J</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Risk Abstracts</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Fire safety journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wolski, Armin</au><au>Dembsey, Nicholas A</au><au>Meacham, Brian J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accommodating perceptions of risk in performance-based building fire safety code development</atitle><jtitle>Fire safety journal</jtitle><date>2000-04-01</date><risdate>2000</risdate><volume>34</volume><issue>3</issue><spage>297</spage><epage>309</epage><pages>297-309</pages><issn>0379-7112</issn><coden>FSJODZ</coden><abstract>Differing perceptions of risk by various stakeholders have long played a role in influencing the development of prescriptive-based building fire safety codes. As performance-based building fire safety codes are developed, differing perceptions of risk will continue to be a significant influence. In this paper, the concepts of revealed preference, risk factors, risk adjustment factors and risk conversion factors are discussed, and two methods to address risk perceptions in a performance-based building fire safety code are introduced. The first method proposes the use of risk factors to classify buildings in terms such as low, medium, and high risk. Each class of building would be assigned a risk adjustment factor. Similar to safety factors, risk adjustment factors would be applied during deterministic building fire safety design to provide an increased level of safety in buildings where the risk perceptions would mandate greater safety. The second method would be used with a probabilistic-based building fire safety design approach, and uses risk factors to develop risk conversion factors (RCFs). In the probabilistic approach, a maximum expected-risk-to-life (ERL) value would be established by the code, with appropriate RCFs being applied to adjust maximum ERL values depending on how the building's fire safety risk is perceived.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/S0379-7112(00)00003-5</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0379-7112
ispartof Fire safety journal, 2000-04, Vol.34 (3), p.297-309
issn 0379-7112
language eng
recordid cdi_proquest_miscellaneous_17539550
source Elsevier ScienceDirect Journals Complete - AutoHoldings
subjects Applied sciences
building codes
Building technical equipments
Buildings
Buildings. Public works
Exact sciences and technology
Fire protection
Fire safety. Legislation
title Accommodating perceptions of risk in performance-based building fire safety code development
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T14%3A17%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accommodating%20perceptions%20of%20risk%20in%20performance-based%20building%20fire%20safety%20code%20development&rft.jtitle=Fire%20safety%20journal&rft.au=Wolski,%20Armin&rft.date=2000-04-01&rft.volume=34&rft.issue=3&rft.spage=297&rft.epage=309&rft.pages=297-309&rft.issn=0379-7112&rft.coden=FSJODZ&rft_id=info:doi/10.1016/S0379-7112(00)00003-5&rft_dat=%3Cproquest_cross%3E17539550%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17539550&rft_id=info:pmid/&rft_els_id=S0379711200000035&rfr_iscdi=true