Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility

Laser scanners have become very popular means of point clouds acquisition and 3D reconstruction. However, the accuracy specifications given by laser scanner producers in their publications and pamphlets are not consistent. Experience shows that sometimes these should not be trusted. Therefore, how t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key engineering materials 2014-08, Vol.625, p.14-19
Hauptverfasser: Li, Jian Shuang, Qian, Zheng Yu, Deng, Xiang Rui
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 19
container_issue
container_start_page 14
container_title Key engineering materials
container_volume 625
creator Li, Jian Shuang
Qian, Zheng Yu
Deng, Xiang Rui
description Laser scanners have become very popular means of point clouds acquisition and 3D reconstruction. However, the accuracy specifications given by laser scanner producers in their publications and pamphlets are not consistent. Experience shows that sometimes these should not be trusted. Therefore, how to reasonably evaluate and quantify main technical parameters of the instruments is particularly important. It is very necessary to investigate in calibration devices and methods that are suitable for laser scanners. The 80m indoor ranging facility of the National Institute of Metrology (NIM) at Beijing, China, is equipped with an interferometer comparator, precise air flotation rail systems and environmental parameter automatical compensation system. The facility is a closed loop feedback control system and can provide a high-precision reference distance value with different intervals. A expanded standard uncertainty (k=2) of U(Ls) is superior to 0.5μm+0.5×10-6L. This paper describes the calibration principle and procedure, including mounting white standard spheres with surfaces of diffuse reflection at the mobile platform as non-contact targets, scanning and measuring the white spheres , fitting the coordinates of the sphere centers and calculating the relative distance among sphere centers. As an example, this paper also presents analysis and evaluation on the measurement uncertainty of ranging accuracy.
doi_str_mv 10.4028/www.scientific.net/KEM.625.14
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753528862</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1753528862</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2134-b9e93a7d08c7005d814e40542c9b7ca26bd01b8b525ae8eeefdb4ae00db9d5453</originalsourceid><addsrcrecordid>eNqNkF9LwzAUxYMoOKffIS-CL-2SNGnTBxEdmw43Bf88hzS93TK6dCYdY9_eyARffbr3cs85cH4IXVOScsLkaL_fp8FYcL1trEkd9KPnySLNmUgpP0EDmucsKYtSnMad0CwpJcvP0UUIa0IyKqkYoOexbm3ldW87h5vO47kO4PG70c6BD_ghnjWOv34F-GW2wJJs8MzVXZS-abe0bomn2tjW9odLdNboNsDV7xyiz-nkY_yUzF8fZ-P7eWIYzXhSlVBmuqiJNAUhopaUAyeCM1NWhdEsr2pCK1kJJjRIAGjqimsgpK7KWnCRDdHNMXfru68dhF5tbDDQttpBtwuKFiITTMqcRentUWp8F4KHRm293Wh_UJSoH4gqQlR_EFWEqCJEFSEqyqP_7ujvvXahB7NS627nXaz3z4RveLuChg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1753528862</pqid></control><display><type>article</type><title>Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility</title><source>Scientific.net Journals</source><creator>Li, Jian Shuang ; Qian, Zheng Yu ; Deng, Xiang Rui</creator><creatorcontrib>Li, Jian Shuang ; Qian, Zheng Yu ; Deng, Xiang Rui</creatorcontrib><description>Laser scanners have become very popular means of point clouds acquisition and 3D reconstruction. However, the accuracy specifications given by laser scanner producers in their publications and pamphlets are not consistent. Experience shows that sometimes these should not be trusted. Therefore, how to reasonably evaluate and quantify main technical parameters of the instruments is particularly important. It is very necessary to investigate in calibration devices and methods that are suitable for laser scanners. The 80m indoor ranging facility of the National Institute of Metrology (NIM) at Beijing, China, is equipped with an interferometer comparator, precise air flotation rail systems and environmental parameter automatical compensation system. The facility is a closed loop feedback control system and can provide a high-precision reference distance value with different intervals. A expanded standard uncertainty (k=2) of U(Ls) is superior to 0.5μm+0.5×10-6L. This paper describes the calibration principle and procedure, including mounting white standard spheres with surfaces of diffuse reflection at the mobile platform as non-contact targets, scanning and measuring the white spheres , fitting the coordinates of the sphere centers and calculating the relative distance among sphere centers. As an example, this paper also presents analysis and evaluation on the measurement uncertainty of ranging accuracy.</description><identifier>ISSN: 1013-9826</identifier><identifier>ISSN: 1662-9795</identifier><identifier>EISSN: 1662-9795</identifier><identifier>DOI: 10.4028/www.scientific.net/KEM.625.14</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><subject>Calibration ; Feedback control ; Indoor ; Interferometers ; Lasers ; Scanners ; Three dimensional models ; Uncertainty</subject><ispartof>Key engineering materials, 2014-08, Vol.625, p.14-19</ispartof><rights>2015 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2134-b9e93a7d08c7005d814e40542c9b7ca26bd01b8b525ae8eeefdb4ae00db9d5453</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/3392?width=600</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Li, Jian Shuang</creatorcontrib><creatorcontrib>Qian, Zheng Yu</creatorcontrib><creatorcontrib>Deng, Xiang Rui</creatorcontrib><title>Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility</title><title>Key engineering materials</title><description>Laser scanners have become very popular means of point clouds acquisition and 3D reconstruction. However, the accuracy specifications given by laser scanner producers in their publications and pamphlets are not consistent. Experience shows that sometimes these should not be trusted. Therefore, how to reasonably evaluate and quantify main technical parameters of the instruments is particularly important. It is very necessary to investigate in calibration devices and methods that are suitable for laser scanners. The 80m indoor ranging facility of the National Institute of Metrology (NIM) at Beijing, China, is equipped with an interferometer comparator, precise air flotation rail systems and environmental parameter automatical compensation system. The facility is a closed loop feedback control system and can provide a high-precision reference distance value with different intervals. A expanded standard uncertainty (k=2) of U(Ls) is superior to 0.5μm+0.5×10-6L. This paper describes the calibration principle and procedure, including mounting white standard spheres with surfaces of diffuse reflection at the mobile platform as non-contact targets, scanning and measuring the white spheres , fitting the coordinates of the sphere centers and calculating the relative distance among sphere centers. As an example, this paper also presents analysis and evaluation on the measurement uncertainty of ranging accuracy.</description><subject>Calibration</subject><subject>Feedback control</subject><subject>Indoor</subject><subject>Interferometers</subject><subject>Lasers</subject><subject>Scanners</subject><subject>Three dimensional models</subject><subject>Uncertainty</subject><issn>1013-9826</issn><issn>1662-9795</issn><issn>1662-9795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqNkF9LwzAUxYMoOKffIS-CL-2SNGnTBxEdmw43Bf88hzS93TK6dCYdY9_eyARffbr3cs85cH4IXVOScsLkaL_fp8FYcL1trEkd9KPnySLNmUgpP0EDmucsKYtSnMad0CwpJcvP0UUIa0IyKqkYoOexbm3ldW87h5vO47kO4PG70c6BD_ghnjWOv34F-GW2wJJs8MzVXZS-abe0bomn2tjW9odLdNboNsDV7xyiz-nkY_yUzF8fZ-P7eWIYzXhSlVBmuqiJNAUhopaUAyeCM1NWhdEsr2pCK1kJJjRIAGjqimsgpK7KWnCRDdHNMXfru68dhF5tbDDQttpBtwuKFiITTMqcRentUWp8F4KHRm293Wh_UJSoH4gqQlR_EFWEqCJEFSEqyqP_7ujvvXahB7NS627nXaz3z4RveLuChg</recordid><startdate>20140801</startdate><enddate>20140801</enddate><creator>Li, Jian Shuang</creator><creator>Qian, Zheng Yu</creator><creator>Deng, Xiang Rui</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20140801</creationdate><title>Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility</title><author>Li, Jian Shuang ; Qian, Zheng Yu ; Deng, Xiang Rui</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2134-b9e93a7d08c7005d814e40542c9b7ca26bd01b8b525ae8eeefdb4ae00db9d5453</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Calibration</topic><topic>Feedback control</topic><topic>Indoor</topic><topic>Interferometers</topic><topic>Lasers</topic><topic>Scanners</topic><topic>Three dimensional models</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Jian Shuang</creatorcontrib><creatorcontrib>Qian, Zheng Yu</creatorcontrib><creatorcontrib>Deng, Xiang Rui</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Key engineering materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Jian Shuang</au><au>Qian, Zheng Yu</au><au>Deng, Xiang Rui</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility</atitle><jtitle>Key engineering materials</jtitle><date>2014-08-01</date><risdate>2014</risdate><volume>625</volume><spage>14</spage><epage>19</epage><pages>14-19</pages><issn>1013-9826</issn><issn>1662-9795</issn><eissn>1662-9795</eissn><abstract>Laser scanners have become very popular means of point clouds acquisition and 3D reconstruction. However, the accuracy specifications given by laser scanner producers in their publications and pamphlets are not consistent. Experience shows that sometimes these should not be trusted. Therefore, how to reasonably evaluate and quantify main technical parameters of the instruments is particularly important. It is very necessary to investigate in calibration devices and methods that are suitable for laser scanners. The 80m indoor ranging facility of the National Institute of Metrology (NIM) at Beijing, China, is equipped with an interferometer comparator, precise air flotation rail systems and environmental parameter automatical compensation system. The facility is a closed loop feedback control system and can provide a high-precision reference distance value with different intervals. A expanded standard uncertainty (k=2) of U(Ls) is superior to 0.5μm+0.5×10-6L. This paper describes the calibration principle and procedure, including mounting white standard spheres with surfaces of diffuse reflection at the mobile platform as non-contact targets, scanning and measuring the white spheres , fitting the coordinates of the sphere centers and calculating the relative distance among sphere centers. As an example, this paper also presents analysis and evaluation on the measurement uncertainty of ranging accuracy.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/KEM.625.14</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1013-9826
ispartof Key engineering materials, 2014-08, Vol.625, p.14-19
issn 1013-9826
1662-9795
1662-9795
language eng
recordid cdi_proquest_miscellaneous_1753528862
source Scientific.net Journals
subjects Calibration
Feedback control
Indoor
Interferometers
Lasers
Scanners
Three dimensional models
Uncertainty
title Calibration for Laser Scanners Based on the NIM 80m Indoor Ranging Facility
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T11%3A49%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20for%20Laser%20Scanners%20Based%20on%20the%20NIM%2080m%20Indoor%20Ranging%20Facility&rft.jtitle=Key%20engineering%20materials&rft.au=Li,%20Jian%20Shuang&rft.date=2014-08-01&rft.volume=625&rft.spage=14&rft.epage=19&rft.pages=14-19&rft.issn=1013-9826&rft.eissn=1662-9795&rft_id=info:doi/10.4028/www.scientific.net/KEM.625.14&rft_dat=%3Cproquest_cross%3E1753528862%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1753528862&rft_id=info:pmid/&rfr_iscdi=true