Accurate purification age determination of individual uranium–plutonium mixed particles
Age of individual uranium–plutonium (U/Pu) mixed particles with various U/Pu atomic ratios (1–70) were determined by inductively coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4–6 years since the las...
Gespeichert in:
Veröffentlicht in: | Analytical and bioanalytical chemistry 2015-09, Vol.407 (23), p.7165-7173 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 7173 |
---|---|
container_issue | 23 |
container_start_page | 7165 |
container_title | Analytical and bioanalytical chemistry |
container_volume | 407 |
creator | Miyamoto, Yutaka Suzuki, Daisuke Esaka, Fumitaka Magara, Masaaki |
description | Age of individual uranium–plutonium (U/Pu) mixed particles with various U/Pu atomic ratios (1–70) were determined by inductively coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4–6 years since the last purification (July 14, 2008). The Pu purification age was obtained from the ²⁴¹Am/²⁴¹Pu ratio which was calculated from the product of three measured ratios of Pu and Am isotopes in the eluted fractions. These ratios were measured by a high-resolution inductively coupled plasma mass spectrometer equipped with a desolvation system. Femto-gram to pico-gram quantities of Am, U, and Pu in a sample solution were sequentially separated on a small anion-exchange column. The ²⁴¹Am/²⁴¹Pu ratio was accurately determined by spiking pure ²⁴³Am into the sample solution. The average determined age for the particles for the five independent U/Pu ratios was in good agreement with the expected age with high accuracy (difference age 0.27 years) and high precision (standard deviation 0.44 years). The described analytical technique can serve as an effective tool for nuclear safeguards and environmental radiochemistry. Figure Young (4‒6 y) Pu purification age of individual U/Pu mixed micron-sized reference particles for the five independent U/Pu ratios (1‒70) were determined with 0.27±0.44 y difference from the expected age. Sub pico-gram quantities of Am, U and Pu were sequentially separated a small column, and their isotope ratios were accurately measured using an ICP-MS by applying the ²⁴³Am spiking technique to the analysis and correcting the impurity and the contaminations. |
doi_str_mv | 10.1007/s00216-015-8880-2 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753523678</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A426930289</galeid><sourcerecordid>A426930289</sourcerecordid><originalsourceid>FETCH-LOGICAL-c674t-c9e9006a8116a1cf2c5ba8421f7f1453ca5c21fa1e7bd12d0da095d03a7f492e3</originalsourceid><addsrcrecordid>eNqNkstu1TAQhiMEoqXwAGwgEptuUmZ8i7M8qqAgVeoCumBl-fhy5CqJg50g2PEOvCFPgqOUCrGoKi88M_7-8Vi_q-olwhkCtG8zAEHRAPJGSgkNeVQdo0DZEMHh8V3MyFH1LOcbKKBE8bQ6IoKAaIEfV192xixJz66elhR8MHoOcaz1wdXWzS4NYdwq0ddhtOFbsIvu6yIZwzL8_vlr6pc5rnE9hO_O1pNOczC9y8-rJ1732b243U-q6_fvPp9_aC6vLj6e7y4bI1o2N6ZzHYDQElFoNJ4YvteSEfStR8ap0dyURKNr9xaJBauh4xaobj3riKMn1enWd0rx6-LyrIaQjet7Pbq4ZIUtp5xQ0coHoExI2XWEPgAFibyVHSvom__Qm7iksbx5vZsJKhnFQp1t1EH3ToXRxzlpU5Z1QzBxdD6U-o4R0VEgsisC3AQmxZyT82pKYdDph0JQq_1qs18VV9VqvyJF8-p2lGU_OHun-Ot3AcgG5HI0Hlz6Z9Z7ur7eRF5HpQ8pZHX9iQAKWH8U5ZL-AXoGw9E</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1754638431</pqid></control><display><type>article</type><title>Accurate purification age determination of individual uranium–plutonium mixed particles</title><source>Springer Online Journals Complete</source><creator>Miyamoto, Yutaka ; Suzuki, Daisuke ; Esaka, Fumitaka ; Magara, Masaaki</creator><creatorcontrib>Miyamoto, Yutaka ; Suzuki, Daisuke ; Esaka, Fumitaka ; Magara, Masaaki</creatorcontrib><description>Age of individual uranium–plutonium (U/Pu) mixed particles with various U/Pu atomic ratios (1–70) were determined by inductively coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4–6 years since the last purification (July 14, 2008). The Pu purification age was obtained from the ²⁴¹Am/²⁴¹Pu ratio which was calculated from the product of three measured ratios of Pu and Am isotopes in the eluted fractions. These ratios were measured by a high-resolution inductively coupled plasma mass spectrometer equipped with a desolvation system. Femto-gram to pico-gram quantities of Am, U, and Pu in a sample solution were sequentially separated on a small anion-exchange column. The ²⁴¹Am/²⁴¹Pu ratio was accurately determined by spiking pure ²⁴³Am into the sample solution. The average determined age for the particles for the five independent U/Pu ratios was in good agreement with the expected age with high accuracy (difference age 0.27 years) and high precision (standard deviation 0.44 years). The described analytical technique can serve as an effective tool for nuclear safeguards and environmental radiochemistry. Figure Young (4‒6 y) Pu purification age of individual U/Pu mixed micron-sized reference particles for the five independent U/Pu ratios (1‒70) were determined with 0.27±0.44 y difference from the expected age. Sub pico-gram quantities of Am, U and Pu were sequentially separated a small column, and their isotope ratios were accurately measured using an ICP-MS by applying the ²⁴³Am spiking technique to the analysis and correcting the impurity and the contaminations.</description><identifier>ISSN: 1618-2642</identifier><identifier>EISSN: 1618-2650</identifier><identifier>DOI: 10.1007/s00216-015-8880-2</identifier><identifier>PMID: 26206705</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Age ; Age determination ; Analytical Chemistry ; anion exchange ; Biochemistry ; Characterization and Evaluation of Materials ; Chemistry ; Chemistry and Materials Science ; Chromatography ; Food Science ; Inductively coupled plasma ; Isotopes ; Laboratory Medicine ; Mass spectrometers ; Mass spectrometry ; Mathematical analysis ; Monitoring/Environmental Analysis ; Nuclear accidents & safety ; Plutonium ; Purification ; Radiochemistry ; Ratios ; Reference materials ; Research Paper ; Scientific imaging ; spectrometers ; Standard deviation ; Uranium</subject><ispartof>Analytical and bioanalytical chemistry, 2015-09, Vol.407 (23), p.7165-7173</ispartof><rights>Springer-Verlag Berlin Heidelberg 2015</rights><rights>COPYRIGHT 2015 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c674t-c9e9006a8116a1cf2c5ba8421f7f1453ca5c21fa1e7bd12d0da095d03a7f492e3</citedby><cites>FETCH-LOGICAL-c674t-c9e9006a8116a1cf2c5ba8421f7f1453ca5c21fa1e7bd12d0da095d03a7f492e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00216-015-8880-2$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00216-015-8880-2$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>315,781,785,27929,27930,41493,42562,51324</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26206705$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miyamoto, Yutaka</creatorcontrib><creatorcontrib>Suzuki, Daisuke</creatorcontrib><creatorcontrib>Esaka, Fumitaka</creatorcontrib><creatorcontrib>Magara, Masaaki</creatorcontrib><title>Accurate purification age determination of individual uranium–plutonium mixed particles</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><addtitle>Anal Bioanal Chem</addtitle><description>Age of individual uranium–plutonium (U/Pu) mixed particles with various U/Pu atomic ratios (1–70) were determined by inductively coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4–6 years since the last purification (July 14, 2008). The Pu purification age was obtained from the ²⁴¹Am/²⁴¹Pu ratio which was calculated from the product of three measured ratios of Pu and Am isotopes in the eluted fractions. These ratios were measured by a high-resolution inductively coupled plasma mass spectrometer equipped with a desolvation system. Femto-gram to pico-gram quantities of Am, U, and Pu in a sample solution were sequentially separated on a small anion-exchange column. The ²⁴¹Am/²⁴¹Pu ratio was accurately determined by spiking pure ²⁴³Am into the sample solution. The average determined age for the particles for the five independent U/Pu ratios was in good agreement with the expected age with high accuracy (difference age 0.27 years) and high precision (standard deviation 0.44 years). The described analytical technique can serve as an effective tool for nuclear safeguards and environmental radiochemistry. Figure Young (4‒6 y) Pu purification age of individual U/Pu mixed micron-sized reference particles for the five independent U/Pu ratios (1‒70) were determined with 0.27±0.44 y difference from the expected age. Sub pico-gram quantities of Am, U and Pu were sequentially separated a small column, and their isotope ratios were accurately measured using an ICP-MS by applying the ²⁴³Am spiking technique to the analysis and correcting the impurity and the contaminations.</description><subject>Age</subject><subject>Age determination</subject><subject>Analytical Chemistry</subject><subject>anion exchange</subject><subject>Biochemistry</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Chromatography</subject><subject>Food Science</subject><subject>Inductively coupled plasma</subject><subject>Isotopes</subject><subject>Laboratory Medicine</subject><subject>Mass spectrometers</subject><subject>Mass spectrometry</subject><subject>Mathematical analysis</subject><subject>Monitoring/Environmental Analysis</subject><subject>Nuclear accidents & safety</subject><subject>Plutonium</subject><subject>Purification</subject><subject>Radiochemistry</subject><subject>Ratios</subject><subject>Reference materials</subject><subject>Research Paper</subject><subject>Scientific imaging</subject><subject>spectrometers</subject><subject>Standard deviation</subject><subject>Uranium</subject><issn>1618-2642</issn><issn>1618-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqNkstu1TAQhiMEoqXwAGwgEptuUmZ8i7M8qqAgVeoCumBl-fhy5CqJg50g2PEOvCFPgqOUCrGoKi88M_7-8Vi_q-olwhkCtG8zAEHRAPJGSgkNeVQdo0DZEMHh8V3MyFH1LOcbKKBE8bQ6IoKAaIEfV192xixJz66elhR8MHoOcaz1wdXWzS4NYdwq0ddhtOFbsIvu6yIZwzL8_vlr6pc5rnE9hO_O1pNOczC9y8-rJ1732b243U-q6_fvPp9_aC6vLj6e7y4bI1o2N6ZzHYDQElFoNJ4YvteSEfStR8ap0dyURKNr9xaJBauh4xaobj3riKMn1enWd0rx6-LyrIaQjet7Pbq4ZIUtp5xQ0coHoExI2XWEPgAFibyVHSvom__Qm7iksbx5vZsJKhnFQp1t1EH3ToXRxzlpU5Z1QzBxdD6U-o4R0VEgsisC3AQmxZyT82pKYdDph0JQq_1qs18VV9VqvyJF8-p2lGU_OHun-Ot3AcgG5HI0Hlz6Z9Z7ur7eRF5HpQ8pZHX9iQAKWH8U5ZL-AXoGw9E</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Miyamoto, Yutaka</creator><creator>Suzuki, Daisuke</creator><creator>Esaka, Fumitaka</creator><creator>Magara, Masaaki</creator><general>Springer Berlin Heidelberg</general><general>Springer</general><general>Springer Nature B.V</general><scope>FBQ</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U7</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>H8G</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KB.</scope><scope>KR7</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>P64</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>7QH</scope><scope>7UA</scope></search><sort><creationdate>20150901</creationdate><title>Accurate purification age determination of individual uranium–plutonium mixed particles</title><author>Miyamoto, Yutaka ; Suzuki, Daisuke ; Esaka, Fumitaka ; Magara, Masaaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c674t-c9e9006a8116a1cf2c5ba8421f7f1453ca5c21fa1e7bd12d0da095d03a7f492e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Age</topic><topic>Age determination</topic><topic>Analytical Chemistry</topic><topic>anion exchange</topic><topic>Biochemistry</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Chromatography</topic><topic>Food Science</topic><topic>Inductively coupled plasma</topic><topic>Isotopes</topic><topic>Laboratory Medicine</topic><topic>Mass spectrometers</topic><topic>Mass spectrometry</topic><topic>Mathematical analysis</topic><topic>Monitoring/Environmental Analysis</topic><topic>Nuclear accidents & safety</topic><topic>Plutonium</topic><topic>Purification</topic><topic>Radiochemistry</topic><topic>Ratios</topic><topic>Reference materials</topic><topic>Research Paper</topic><topic>Scientific imaging</topic><topic>spectrometers</topic><topic>Standard deviation</topic><topic>Uranium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miyamoto, Yutaka</creatorcontrib><creatorcontrib>Suzuki, Daisuke</creatorcontrib><creatorcontrib>Esaka, Fumitaka</creatorcontrib><creatorcontrib>Magara, Masaaki</creatorcontrib><collection>AGRIS</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miyamoto, Yutaka</au><au>Suzuki, Daisuke</au><au>Esaka, Fumitaka</au><au>Magara, Masaaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accurate purification age determination of individual uranium–plutonium mixed particles</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><stitle>Anal Bioanal Chem</stitle><addtitle>Anal Bioanal Chem</addtitle><date>2015-09-01</date><risdate>2015</risdate><volume>407</volume><issue>23</issue><spage>7165</spage><epage>7173</epage><pages>7165-7173</pages><issn>1618-2642</issn><eissn>1618-2650</eissn><abstract>Age of individual uranium–plutonium (U/Pu) mixed particles with various U/Pu atomic ratios (1–70) were determined by inductively coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4–6 years since the last purification (July 14, 2008). The Pu purification age was obtained from the ²⁴¹Am/²⁴¹Pu ratio which was calculated from the product of three measured ratios of Pu and Am isotopes in the eluted fractions. These ratios were measured by a high-resolution inductively coupled plasma mass spectrometer equipped with a desolvation system. Femto-gram to pico-gram quantities of Am, U, and Pu in a sample solution were sequentially separated on a small anion-exchange column. The ²⁴¹Am/²⁴¹Pu ratio was accurately determined by spiking pure ²⁴³Am into the sample solution. The average determined age for the particles for the five independent U/Pu ratios was in good agreement with the expected age with high accuracy (difference age 0.27 years) and high precision (standard deviation 0.44 years). The described analytical technique can serve as an effective tool for nuclear safeguards and environmental radiochemistry. Figure Young (4‒6 y) Pu purification age of individual U/Pu mixed micron-sized reference particles for the five independent U/Pu ratios (1‒70) were determined with 0.27±0.44 y difference from the expected age. Sub pico-gram quantities of Am, U and Pu were sequentially separated a small column, and their isotope ratios were accurately measured using an ICP-MS by applying the ²⁴³Am spiking technique to the analysis and correcting the impurity and the contaminations.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>26206705</pmid><doi>10.1007/s00216-015-8880-2</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1618-2642 |
ispartof | Analytical and bioanalytical chemistry, 2015-09, Vol.407 (23), p.7165-7173 |
issn | 1618-2642 1618-2650 |
language | eng |
recordid | cdi_proquest_miscellaneous_1753523678 |
source | Springer Online Journals Complete |
subjects | Age Age determination Analytical Chemistry anion exchange Biochemistry Characterization and Evaluation of Materials Chemistry Chemistry and Materials Science Chromatography Food Science Inductively coupled plasma Isotopes Laboratory Medicine Mass spectrometers Mass spectrometry Mathematical analysis Monitoring/Environmental Analysis Nuclear accidents & safety Plutonium Purification Radiochemistry Ratios Reference materials Research Paper Scientific imaging spectrometers Standard deviation Uranium |
title | Accurate purification age determination of individual uranium–plutonium mixed particles |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T06%3A44%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accurate%20purification%20age%20determination%20of%20individual%20uranium%E2%80%93plutonium%20mixed%20particles&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=Miyamoto,%20Yutaka&rft.date=2015-09-01&rft.volume=407&rft.issue=23&rft.spage=7165&rft.epage=7173&rft.pages=7165-7173&rft.issn=1618-2642&rft.eissn=1618-2650&rft_id=info:doi/10.1007/s00216-015-8880-2&rft_dat=%3Cgale_proqu%3EA426930289%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1754638431&rft_id=info:pmid/26206705&rft_galeid=A426930289&rfr_iscdi=true |