Early Warning for DC Power Failure System
Electrical systems and devices suffer from unexpected failures due to various reasons such as input voltage fluctuation and low or high voltages. This paper discussedabout the development of a device for detecting imminent failure of electric products such as refrigerators, ovens, Air-conditions and...
Gespeichert in:
Veröffentlicht in: | Applied mechanics and materials 2015-09, Vol.793 (Electrical Power Engineering and Sustainable Development of Industry), p.124-128 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 128 |
---|---|
container_issue | Electrical Power Engineering and Sustainable Development of Industry |
container_start_page | 124 |
container_title | Applied mechanics and materials |
container_volume | 793 |
creator | Yusoff, Mohd Irwan Hussain, Abadal Salam T. Mahmoud, Jailani O. Abdullah, Ahmad Zaidi Irwanto Misrun, Muhammad Dahham, Israa A. Taha, Taha A. Malek, F. Jeflawi, Qais H. Shasidharan, Gomesh Nair |
description | Electrical systems and devices suffer from unexpected failures due to various reasons such as input voltage fluctuation and low or high voltages. This paper discussedabout the development of a device for detecting imminent failure of electric products such as refrigerators, ovens, Air-conditions and etc. The main objective of this developed preventive device is todetect voltage drop or rise and produce an alarmsignal to enable and activates other protection circuitry.The mechanismof the detector/sensing circuit is based on differentiating the voltage level using dualcomparator; this makes the system more considerate. The method enables real-time monitoring of stability boundaries and the corresponding margin to the observed operating point, which is used to provide an early warning for emerging stability problems. |
doi_str_mv | 10.4028/www.scientific.net/AMM.793.124 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753521683</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1753521683</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2214-f44360a8f2d51722735ae0e1b11a04c1cda4cac0d3d6cd49a0cfdf1b45ca77ba3</originalsourceid><addsrcrecordid>eNqNkF1LwzAUQIMf4Jz7DwVB9KFdvpO-iGNuKmwoqPgYsjTRjq6dScvYvzc6QfHJp_twD-deDgBnCGYUYjncbDZZMKWt29KVJqttOxzN55nISYYw3QM9xDlOBZV4HwxyIQkkkjCWS3rwtYNpTgg_AschLCHkFFHZAxcT7att8qJ9XdaviWt8cj1OHpqN9clUl1XnbfK4Da1dnYBDp6tgB9-zD56nk6fxbTq7v7kbj2apwRjR1FFKONTS4YIhgbEgTFto0QIhDalBptDUaAMLUnBT0FxD4wqHFpQZLcRCkz4433nXvnnvbGjVqgzGVpWubdMFhQQjDCMuSURP_6DLpvN1_C5SiJOcSSkidbmjjG9C8NaptS9X2m8VguqzrIpl1U9ZFcuqWFbFsiqWjYKrnaD1uo4pzNuvO_9TfAAc54Ye</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1716395887</pqid></control><display><type>article</type><title>Early Warning for DC Power Failure System</title><source>Scientific.net Journals</source><creator>Yusoff, Mohd Irwan ; Hussain, Abadal Salam T. ; Mahmoud, Jailani O. ; Abdullah, Ahmad Zaidi ; Irwanto Misrun, Muhammad ; Dahham, Israa A. ; Taha, Taha A. ; Malek, F. ; Jeflawi, Qais H. ; Shasidharan, Gomesh Nair</creator><creatorcontrib>Yusoff, Mohd Irwan ; Hussain, Abadal Salam T. ; Mahmoud, Jailani O. ; Abdullah, Ahmad Zaidi ; Irwanto Misrun, Muhammad ; Dahham, Israa A. ; Taha, Taha A. ; Malek, F. ; Jeflawi, Qais H. ; Shasidharan, Gomesh Nair</creatorcontrib><description>Electrical systems and devices suffer from unexpected failures due to various reasons such as input voltage fluctuation and low or high voltages. This paper discussedabout the development of a device for detecting imminent failure of electric products such as refrigerators, ovens, Air-conditions and etc. The main objective of this developed preventive device is todetect voltage drop or rise and produce an alarmsignal to enable and activates other protection circuitry.The mechanismof the detector/sensing circuit is based on differentiating the voltage level using dualcomparator; this makes the system more considerate. The method enables real-time monitoring of stability boundaries and the corresponding margin to the observed operating point, which is used to provide an early warning for emerging stability problems.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783038355984</identifier><identifier>ISBN: 3038355984</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.793.124</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Circuits ; Devices ; Electric potential ; Failure ; Refrigerators ; Stability ; Voltage ; Warning</subject><ispartof>Applied mechanics and materials, 2015-09, Vol.793 (Electrical Power Engineering and Sustainable Development of Industry), p.124-128</ispartof><rights>2015 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Sep 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2214-f44360a8f2d51722735ae0e1b11a04c1cda4cac0d3d6cd49a0cfdf1b45ca77ba3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/4172?width=600</thumbnail><link.rule.ids>315,782,786,27933,27934</link.rule.ids></links><search><creatorcontrib>Yusoff, Mohd Irwan</creatorcontrib><creatorcontrib>Hussain, Abadal Salam T.</creatorcontrib><creatorcontrib>Mahmoud, Jailani O.</creatorcontrib><creatorcontrib>Abdullah, Ahmad Zaidi</creatorcontrib><creatorcontrib>Irwanto Misrun, Muhammad</creatorcontrib><creatorcontrib>Dahham, Israa A.</creatorcontrib><creatorcontrib>Taha, Taha A.</creatorcontrib><creatorcontrib>Malek, F.</creatorcontrib><creatorcontrib>Jeflawi, Qais H.</creatorcontrib><creatorcontrib>Shasidharan, Gomesh Nair</creatorcontrib><title>Early Warning for DC Power Failure System</title><title>Applied mechanics and materials</title><description>Electrical systems and devices suffer from unexpected failures due to various reasons such as input voltage fluctuation and low or high voltages. This paper discussedabout the development of a device for detecting imminent failure of electric products such as refrigerators, ovens, Air-conditions and etc. The main objective of this developed preventive device is todetect voltage drop or rise and produce an alarmsignal to enable and activates other protection circuitry.The mechanismof the detector/sensing circuit is based on differentiating the voltage level using dualcomparator; this makes the system more considerate. The method enables real-time monitoring of stability boundaries and the corresponding margin to the observed operating point, which is used to provide an early warning for emerging stability problems.</description><subject>Circuits</subject><subject>Devices</subject><subject>Electric potential</subject><subject>Failure</subject><subject>Refrigerators</subject><subject>Stability</subject><subject>Voltage</subject><subject>Warning</subject><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783038355984</isbn><isbn>3038355984</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkF1LwzAUQIMf4Jz7DwVB9KFdvpO-iGNuKmwoqPgYsjTRjq6dScvYvzc6QfHJp_twD-deDgBnCGYUYjncbDZZMKWt29KVJqttOxzN55nISYYw3QM9xDlOBZV4HwxyIQkkkjCWS3rwtYNpTgg_AschLCHkFFHZAxcT7att8qJ9XdaviWt8cj1OHpqN9clUl1XnbfK4Da1dnYBDp6tgB9-zD56nk6fxbTq7v7kbj2apwRjR1FFKONTS4YIhgbEgTFto0QIhDalBptDUaAMLUnBT0FxD4wqHFpQZLcRCkz4433nXvnnvbGjVqgzGVpWubdMFhQQjDCMuSURP_6DLpvN1_C5SiJOcSSkidbmjjG9C8NaptS9X2m8VguqzrIpl1U9ZFcuqWFbFsiqWjYKrnaD1uo4pzNuvO_9TfAAc54Ye</recordid><startdate>20150901</startdate><enddate>20150901</enddate><creator>Yusoff, Mohd Irwan</creator><creator>Hussain, Abadal Salam T.</creator><creator>Mahmoud, Jailani O.</creator><creator>Abdullah, Ahmad Zaidi</creator><creator>Irwanto Misrun, Muhammad</creator><creator>Dahham, Israa A.</creator><creator>Taha, Taha A.</creator><creator>Malek, F.</creator><creator>Jeflawi, Qais H.</creator><creator>Shasidharan, Gomesh Nair</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>7SP</scope><scope>L7M</scope></search><sort><creationdate>20150901</creationdate><title>Early Warning for DC Power Failure System</title><author>Yusoff, Mohd Irwan ; Hussain, Abadal Salam T. ; Mahmoud, Jailani O. ; Abdullah, Ahmad Zaidi ; Irwanto Misrun, Muhammad ; Dahham, Israa A. ; Taha, Taha A. ; Malek, F. ; Jeflawi, Qais H. ; Shasidharan, Gomesh Nair</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2214-f44360a8f2d51722735ae0e1b11a04c1cda4cac0d3d6cd49a0cfdf1b45ca77ba3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Circuits</topic><topic>Devices</topic><topic>Electric potential</topic><topic>Failure</topic><topic>Refrigerators</topic><topic>Stability</topic><topic>Voltage</topic><topic>Warning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yusoff, Mohd Irwan</creatorcontrib><creatorcontrib>Hussain, Abadal Salam T.</creatorcontrib><creatorcontrib>Mahmoud, Jailani O.</creatorcontrib><creatorcontrib>Abdullah, Ahmad Zaidi</creatorcontrib><creatorcontrib>Irwanto Misrun, Muhammad</creatorcontrib><creatorcontrib>Dahham, Israa A.</creatorcontrib><creatorcontrib>Taha, Taha A.</creatorcontrib><creatorcontrib>Malek, F.</creatorcontrib><creatorcontrib>Jeflawi, Qais H.</creatorcontrib><creatorcontrib>Shasidharan, Gomesh Nair</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central UK/Ireland</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>Electronics & Communications Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied mechanics and materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yusoff, Mohd Irwan</au><au>Hussain, Abadal Salam T.</au><au>Mahmoud, Jailani O.</au><au>Abdullah, Ahmad Zaidi</au><au>Irwanto Misrun, Muhammad</au><au>Dahham, Israa A.</au><au>Taha, Taha A.</au><au>Malek, F.</au><au>Jeflawi, Qais H.</au><au>Shasidharan, Gomesh Nair</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Early Warning for DC Power Failure System</atitle><jtitle>Applied mechanics and materials</jtitle><date>2015-09-01</date><risdate>2015</risdate><volume>793</volume><issue>Electrical Power Engineering and Sustainable Development of Industry</issue><spage>124</spage><epage>128</epage><pages>124-128</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783038355984</isbn><isbn>3038355984</isbn><abstract>Electrical systems and devices suffer from unexpected failures due to various reasons such as input voltage fluctuation and low or high voltages. This paper discussedabout the development of a device for detecting imminent failure of electric products such as refrigerators, ovens, Air-conditions and etc. The main objective of this developed preventive device is todetect voltage drop or rise and produce an alarmsignal to enable and activates other protection circuitry.The mechanismof the detector/sensing circuit is based on differentiating the voltage level using dualcomparator; this makes the system more considerate. The method enables real-time monitoring of stability boundaries and the corresponding margin to the observed operating point, which is used to provide an early warning for emerging stability problems.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.793.124</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1660-9336 |
ispartof | Applied mechanics and materials, 2015-09, Vol.793 (Electrical Power Engineering and Sustainable Development of Industry), p.124-128 |
issn | 1660-9336 1662-7482 1662-7482 |
language | eng |
recordid | cdi_proquest_miscellaneous_1753521683 |
source | Scientific.net Journals |
subjects | Circuits Devices Electric potential Failure Refrigerators Stability Voltage Warning |
title | Early Warning for DC Power Failure System |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-03T14%3A27%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Early%20Warning%20for%20DC%20Power%20Failure%20System&rft.jtitle=Applied%20mechanics%20and%20materials&rft.au=Yusoff,%20Mohd%20Irwan&rft.date=2015-09-01&rft.volume=793&rft.issue=Electrical%20Power%20Engineering%20and%20Sustainable%20Development%20of%20Industry&rft.spage=124&rft.epage=128&rft.pages=124-128&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783038355984&rft.isbn_list=3038355984&rft_id=info:doi/10.4028/www.scientific.net/AMM.793.124&rft_dat=%3Cproquest_cross%3E1753521683%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1716395887&rft_id=info:pmid/&rfr_iscdi=true |