Pulsed neutron imaging using 2-dimensional position sensitive detectors

2-dimensional position sensitive detectors are used for pulsed neutron imaging and at each pixel of the detector a time of flight spectrum is recorded. Therefore, a transmission spectrum through the object has wavelength dependent structure reflecting the neutron total cross section. For such measur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2014-07, Vol.9 (7), p.C07012-C07012
Hauptverfasser: Kiyanagi, Y, Kamiyama, T, Kino, K, Sato, H, Sato, S, Uno, S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page C07012
container_issue 7
container_start_page C07012
container_title Journal of instrumentation
container_volume 9
creator Kiyanagi, Y
Kamiyama, T
Kino, K
Sato, H
Sato, S
Uno, S
description 2-dimensional position sensitive detectors are used for pulsed neutron imaging and at each pixel of the detector a time of flight spectrum is recorded. Therefore, a transmission spectrum through the object has wavelength dependent structure reflecting the neutron total cross section. For such measurements, the detectors are required to have ability to store neutron events as a function of the flight time as well as to have good spatial resolution. Furthermore, high counting rate is also required at the high intensity neutron sources like J-PARC neutron source in Japan. We have developed several types of detectors with different characteristics; two counting type detectors for high counting rate with coarse spatial resolution and one camera type detector for high spatial resolution. One of counting type detectors is a pixel type. The highest counting rate is about 28 MHz. Better spatial resolution is obtained by a GEM detector. Effective area is 10 x 10 cm super(2), pixel size is 0.8 mm. The maximum counting rate is 3.65 MHz. To get higher spatial resolution we are now developing the camera type detector system using a neutron image intensifier, which have image integration function as a function of time of flight. We have succeeded to obtain time dependent images in this camera system. By using these detectors we performed transmission measurements for obtaining the crystallographic information and elemental distribution images.
doi_str_mv 10.1088/1748-0221/9/07/C07012
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753474758</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1753474758</sourcerecordid><originalsourceid>FETCH-LOGICAL-c286t-2b2e02eb543e32d0fbaba6c7227398d1c63933c9dbe2905377cbb0fe479633623</originalsourceid><addsrcrecordid>eNpNkEFLxDAUhIMouK7-BKFHL7UvSdM0R1l0V1jQg55Dk74ukbZZk1Tw39uyIl7eDMMw8D5CbincU6jrgsqyzoExWqgCZLEBCZSdkdVffv7PX5KrGD8AhBIlrMj2deojttmIUwp-zNzQHNx4yKa4XJa3bsAxOj82fXb00aXZZnGJkvvCrMWENvkQr8lF18xLN7-6Ju9Pj2-bXb5_2T5vHva5ZXWVcmYYAkMjSo6ctdCZxjSVlYxJruqW2oorzq1qDTIFgktpjYEOS6kqzivG1-TutHsM_nPCmPTgosW-b0b0U9RUCl7KUop6ropT1QYfY8BOH8P8XvjWFPQCTi9Q9AJFKw1Sn8DxHx4zYVY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1753474758</pqid></control><display><type>article</type><title>Pulsed neutron imaging using 2-dimensional position sensitive detectors</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Kiyanagi, Y ; Kamiyama, T ; Kino, K ; Sato, H ; Sato, S ; Uno, S</creator><creatorcontrib>Kiyanagi, Y ; Kamiyama, T ; Kino, K ; Sato, H ; Sato, S ; Uno, S</creatorcontrib><description>2-dimensional position sensitive detectors are used for pulsed neutron imaging and at each pixel of the detector a time of flight spectrum is recorded. Therefore, a transmission spectrum through the object has wavelength dependent structure reflecting the neutron total cross section. For such measurements, the detectors are required to have ability to store neutron events as a function of the flight time as well as to have good spatial resolution. Furthermore, high counting rate is also required at the high intensity neutron sources like J-PARC neutron source in Japan. We have developed several types of detectors with different characteristics; two counting type detectors for high counting rate with coarse spatial resolution and one camera type detector for high spatial resolution. One of counting type detectors is a pixel type. The highest counting rate is about 28 MHz. Better spatial resolution is obtained by a GEM detector. Effective area is 10 x 10 cm super(2), pixel size is 0.8 mm. The maximum counting rate is 3.65 MHz. To get higher spatial resolution we are now developing the camera type detector system using a neutron image intensifier, which have image integration function as a function of time of flight. We have succeeded to obtain time dependent images in this camera system. By using these detectors we performed transmission measurements for obtaining the crystallographic information and elemental distribution images.</description><identifier>ISSN: 1748-0221</identifier><identifier>EISSN: 1748-0221</identifier><identifier>DOI: 10.1088/1748-0221/9/07/C07012</identifier><language>eng</language><subject>Cameras ; Counting ; Detectors ; Imaging ; Neutron sources ; Pixels ; Position sensitive ; Spatial resolution</subject><ispartof>Journal of instrumentation, 2014-07, Vol.9 (7), p.C07012-C07012</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c286t-2b2e02eb543e32d0fbaba6c7227398d1c63933c9dbe2905377cbb0fe479633623</citedby><cites>FETCH-LOGICAL-c286t-2b2e02eb543e32d0fbaba6c7227398d1c63933c9dbe2905377cbb0fe479633623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Kiyanagi, Y</creatorcontrib><creatorcontrib>Kamiyama, T</creatorcontrib><creatorcontrib>Kino, K</creatorcontrib><creatorcontrib>Sato, H</creatorcontrib><creatorcontrib>Sato, S</creatorcontrib><creatorcontrib>Uno, S</creatorcontrib><title>Pulsed neutron imaging using 2-dimensional position sensitive detectors</title><title>Journal of instrumentation</title><description>2-dimensional position sensitive detectors are used for pulsed neutron imaging and at each pixel of the detector a time of flight spectrum is recorded. Therefore, a transmission spectrum through the object has wavelength dependent structure reflecting the neutron total cross section. For such measurements, the detectors are required to have ability to store neutron events as a function of the flight time as well as to have good spatial resolution. Furthermore, high counting rate is also required at the high intensity neutron sources like J-PARC neutron source in Japan. We have developed several types of detectors with different characteristics; two counting type detectors for high counting rate with coarse spatial resolution and one camera type detector for high spatial resolution. One of counting type detectors is a pixel type. The highest counting rate is about 28 MHz. Better spatial resolution is obtained by a GEM detector. Effective area is 10 x 10 cm super(2), pixel size is 0.8 mm. The maximum counting rate is 3.65 MHz. To get higher spatial resolution we are now developing the camera type detector system using a neutron image intensifier, which have image integration function as a function of time of flight. We have succeeded to obtain time dependent images in this camera system. By using these detectors we performed transmission measurements for obtaining the crystallographic information and elemental distribution images.</description><subject>Cameras</subject><subject>Counting</subject><subject>Detectors</subject><subject>Imaging</subject><subject>Neutron sources</subject><subject>Pixels</subject><subject>Position sensitive</subject><subject>Spatial resolution</subject><issn>1748-0221</issn><issn>1748-0221</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpNkEFLxDAUhIMouK7-BKFHL7UvSdM0R1l0V1jQg55Dk74ukbZZk1Tw39uyIl7eDMMw8D5CbincU6jrgsqyzoExWqgCZLEBCZSdkdVffv7PX5KrGD8AhBIlrMj2deojttmIUwp-zNzQHNx4yKa4XJa3bsAxOj82fXb00aXZZnGJkvvCrMWENvkQr8lF18xLN7-6Ju9Pj2-bXb5_2T5vHva5ZXWVcmYYAkMjSo6ctdCZxjSVlYxJruqW2oorzq1qDTIFgktpjYEOS6kqzivG1-TutHsM_nPCmPTgosW-b0b0U9RUCl7KUop6ropT1QYfY8BOH8P8XvjWFPQCTi9Q9AJFKw1Sn8DxHx4zYVY</recordid><startdate>20140701</startdate><enddate>20140701</enddate><creator>Kiyanagi, Y</creator><creator>Kamiyama, T</creator><creator>Kino, K</creator><creator>Sato, H</creator><creator>Sato, S</creator><creator>Uno, S</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20140701</creationdate><title>Pulsed neutron imaging using 2-dimensional position sensitive detectors</title><author>Kiyanagi, Y ; Kamiyama, T ; Kino, K ; Sato, H ; Sato, S ; Uno, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c286t-2b2e02eb543e32d0fbaba6c7227398d1c63933c9dbe2905377cbb0fe479633623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Cameras</topic><topic>Counting</topic><topic>Detectors</topic><topic>Imaging</topic><topic>Neutron sources</topic><topic>Pixels</topic><topic>Position sensitive</topic><topic>Spatial resolution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kiyanagi, Y</creatorcontrib><creatorcontrib>Kamiyama, T</creatorcontrib><creatorcontrib>Kino, K</creatorcontrib><creatorcontrib>Sato, H</creatorcontrib><creatorcontrib>Sato, S</creatorcontrib><creatorcontrib>Uno, S</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of instrumentation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kiyanagi, Y</au><au>Kamiyama, T</au><au>Kino, K</au><au>Sato, H</au><au>Sato, S</au><au>Uno, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pulsed neutron imaging using 2-dimensional position sensitive detectors</atitle><jtitle>Journal of instrumentation</jtitle><date>2014-07-01</date><risdate>2014</risdate><volume>9</volume><issue>7</issue><spage>C07012</spage><epage>C07012</epage><pages>C07012-C07012</pages><issn>1748-0221</issn><eissn>1748-0221</eissn><abstract>2-dimensional position sensitive detectors are used for pulsed neutron imaging and at each pixel of the detector a time of flight spectrum is recorded. Therefore, a transmission spectrum through the object has wavelength dependent structure reflecting the neutron total cross section. For such measurements, the detectors are required to have ability to store neutron events as a function of the flight time as well as to have good spatial resolution. Furthermore, high counting rate is also required at the high intensity neutron sources like J-PARC neutron source in Japan. We have developed several types of detectors with different characteristics; two counting type detectors for high counting rate with coarse spatial resolution and one camera type detector for high spatial resolution. One of counting type detectors is a pixel type. The highest counting rate is about 28 MHz. Better spatial resolution is obtained by a GEM detector. Effective area is 10 x 10 cm super(2), pixel size is 0.8 mm. The maximum counting rate is 3.65 MHz. To get higher spatial resolution we are now developing the camera type detector system using a neutron image intensifier, which have image integration function as a function of time of flight. We have succeeded to obtain time dependent images in this camera system. By using these detectors we performed transmission measurements for obtaining the crystallographic information and elemental distribution images.</abstract><doi>10.1088/1748-0221/9/07/C07012</doi></addata></record>
fulltext fulltext
identifier ISSN: 1748-0221
ispartof Journal of instrumentation, 2014-07, Vol.9 (7), p.C07012-C07012
issn 1748-0221
1748-0221
language eng
recordid cdi_proquest_miscellaneous_1753474758
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Cameras
Counting
Detectors
Imaging
Neutron sources
Pixels
Position sensitive
Spatial resolution
title Pulsed neutron imaging using 2-dimensional position sensitive detectors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T04%3A03%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pulsed%20neutron%20imaging%20using%202-dimensional%20position%20sensitive%20detectors&rft.jtitle=Journal%20of%20instrumentation&rft.au=Kiyanagi,%20Y&rft.date=2014-07-01&rft.volume=9&rft.issue=7&rft.spage=C07012&rft.epage=C07012&rft.pages=C07012-C07012&rft.issn=1748-0221&rft.eissn=1748-0221&rft_id=info:doi/10.1088/1748-0221/9/07/C07012&rft_dat=%3Cproquest_cross%3E1753474758%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1753474758&rft_id=info:pmid/&rfr_iscdi=true