Multiplexed Quantification of Proglucagon-Derived Peptides by Immunoaffinity Enrichment and Tandem Mass Spectrometry after a Meal Tolerance Test

Proglucagon-derived peptides (PGDPs), which include glucagon-like peptide (GLP)-1, glucagon, and oxyntomodulin, are key regulators of glucose homeostasis and satiety. These peptide hormones are typically measured with immuno-based assays (e.g., ELISA, RIA), which often suffer from issues of selectiv...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry (Baltimore, Md.) Md.), 2016-01, Vol.62 (1), p.227-235
Hauptverfasser: Lee, Anita Y H, Chappell, Derek L, Bak, Monika J, Judo, Michael, Liang, Linda, Churakova, Tatyana, Ayanoglu, Gulesi, Castro-Perez, Jose, Zhou, Haihong, Previs, Stephen, Souza, Sandra C, Lassman, Michael E, Laterza, Omar F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Proglucagon-derived peptides (PGDPs), which include glucagon-like peptide (GLP)-1, glucagon, and oxyntomodulin, are key regulators of glucose homeostasis and satiety. These peptide hormones are typically measured with immuno-based assays (e.g., ELISA, RIA), which often suffer from issues of selectivity. We developed a multiplexed assay for measuring PGDPs including GLP-1 (7-36) amide, GLP-1 (9-36) amide, glucagon, and oxyntomodulin by mass spectrometry and used this assay to examine the effect of a meal tolerance test on circulating concentrations of these hormones. Participants fasted overnight and were either given a meal (n = 8) or continued to fast (n = 4), with multiple blood collections over the course of 3 h. Plasma samples were analyzed by microflow immunoaffinity (IA)-LC-MS/MS with an isotope dilution strategy. Assay performance characteristics were examined and established during analytical validation for all peptides. Intra- and interassay imprecision were found to be 2.2%-10.7% and 6.8%-22.5%, respectively. Spike recovery was >76%, and dilution linearity was established up to a 16-fold dilution. Immediately after the meal tolerance test, GLP-1 and oxyntomodulin concentrations increased and had an almost identical temporal relationship, and glucagon concentrations increased with a slight delay. IA-LC-MS/MS was used for the simultaneous and selective measurement of PGDPs. This work includes the first indication of the physiological concentrations and modulation of oxyntomodulin after a meal.
ISSN:0009-9147
1530-8561
DOI:10.1373/clinchem.2015.244251