Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying

The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300nm oxide coated silicon wafer substrate (Si+SiO2) for th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2016-03, Vol.149, p.53-61
Hauptverfasser: Aras, Nadir, Yalçın, Şerife
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 61
container_issue
container_start_page 53
container_title Talanta (Oxford)
container_volume 149
creator Aras, Nadir
Yalçın, Şerife
description The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3pg Cu, 3.3pg Mn, 79pg Cd and 48pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology. [Display omitted] •A laser induced breakdown method on direct analysis of dried droplets is described.•300nm thick oxide coated silicon wafer (Si+SiO2) was used as a substrate.•Energetic laser pulses are focused onto the droplets, at the out of focus condition.•Measurements indicate 7 times enhancement in S/N for Cu(I) line at 324.75nm.•Technique can identify pg amounts of toxic elements in aqueous environments.
doi_str_mv 10.1016/j.talanta.2015.11.031
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753008043</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914015304860</els_id><sourcerecordid>1753008043</sourcerecordid><originalsourceid>FETCH-LOGICAL-c478t-7a25be33beb0bafd281d280f6976893856c7d29dabafa231c8f8bd08e6dec66d3</originalsourceid><addsrcrecordid>eNqFUUGO1DAQtBCInV14AshHDpvQjiexc0JogAVpERzgbDl2BzwkdrCdQfsivomHGfbKodVquaqrXUXIMwY1A9a93NdZT9pnXTfA2pqxGjh7QDZMCl7xVvCHZAPA-6pnW7gglyntAaDhwB-Ti6YTTEjGN-T3GzzgFJYZfabaW3rQk7M6u-BpGKmmk04YK-ftatDSIaL-YcMvT9OCJseQTFicoTPm78HSMUS6TjnqqpRBajFjnJ2_37dbr-lHf0139q_Y5-HI1FOizlP9c8WwJmpjWCbMieqxsMt45_y3J-TRWHD49NyvyNd3b7_s3le3n24-7F7fVmYrZK6EbtoBOR9wgEGPtpGsFIxdLzrZc9l2Rtimt7o86oYzI0c5WJDYWTRdZ_kVeXHau8RQ7klZzS4ZnIrVx-MUEy0HkLDlBdqeoKbYkCKOaolu1vFOMVDHjNRenTNSx4wUY6pkVHjPzxLrMKO9Z_0LpQBenQBYPnpwGFUyDn3x38ViurLB_UfiD7ZrqS4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1753008043</pqid></control><display><type>article</type><title>Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying</title><source>Elsevier ScienceDirect Journals</source><creator>Aras, Nadir ; Yalçın, Şerife</creator><creatorcontrib>Aras, Nadir ; Yalçın, Şerife</creatorcontrib><description>The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3pg Cu, 3.3pg Mn, 79pg Cd and 48pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology. [Display omitted] •A laser induced breakdown method on direct analysis of dried droplets is described.•300nm thick oxide coated silicon wafer (Si+SiO2) was used as a substrate.•Energetic laser pulses are focused onto the droplets, at the out of focus condition.•Measurements indicate 7 times enhancement in S/N for Cu(I) line at 324.75nm.•Technique can identify pg amounts of toxic elements in aqueous environments.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2015.11.031</identifier><identifier>PMID: 26717813</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Laser-induced breakdown spectroscopy ; Liquid droplet analysis ; Oxidized silicon wafer substrate (Si+SiO2)</subject><ispartof>Talanta (Oxford), 2016-03, Vol.149, p.53-61</ispartof><rights>2015 Elsevier B.V.</rights><rights>Copyright © 2015 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c478t-7a25be33beb0bafd281d280f6976893856c7d29dabafa231c8f8bd08e6dec66d3</citedby><cites>FETCH-LOGICAL-c478t-7a25be33beb0bafd281d280f6976893856c7d29dabafa231c8f8bd08e6dec66d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914015304860$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26717813$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Aras, Nadir</creatorcontrib><creatorcontrib>Yalçın, Şerife</creatorcontrib><title>Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3pg Cu, 3.3pg Mn, 79pg Cd and 48pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology. [Display omitted] •A laser induced breakdown method on direct analysis of dried droplets is described.•300nm thick oxide coated silicon wafer (Si+SiO2) was used as a substrate.•Energetic laser pulses are focused onto the droplets, at the out of focus condition.•Measurements indicate 7 times enhancement in S/N for Cu(I) line at 324.75nm.•Technique can identify pg amounts of toxic elements in aqueous environments.</description><subject>Laser-induced breakdown spectroscopy</subject><subject>Liquid droplet analysis</subject><subject>Oxidized silicon wafer substrate (Si+SiO2)</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqFUUGO1DAQtBCInV14AshHDpvQjiexc0JogAVpERzgbDl2BzwkdrCdQfsivomHGfbKodVquaqrXUXIMwY1A9a93NdZT9pnXTfA2pqxGjh7QDZMCl7xVvCHZAPA-6pnW7gglyntAaDhwB-Ti6YTTEjGN-T3GzzgFJYZfabaW3rQk7M6u-BpGKmmk04YK-ftatDSIaL-YcMvT9OCJseQTFicoTPm78HSMUS6TjnqqpRBajFjnJ2_37dbr-lHf0139q_Y5-HI1FOizlP9c8WwJmpjWCbMieqxsMt45_y3J-TRWHD49NyvyNd3b7_s3le3n24-7F7fVmYrZK6EbtoBOR9wgEGPtpGsFIxdLzrZc9l2Rtimt7o86oYzI0c5WJDYWTRdZ_kVeXHau8RQ7klZzS4ZnIrVx-MUEy0HkLDlBdqeoKbYkCKOaolu1vFOMVDHjNRenTNSx4wUY6pkVHjPzxLrMKO9Z_0LpQBenQBYPnpwGFUyDn3x38ViurLB_UfiD7ZrqS4</recordid><startdate>20160301</startdate><enddate>20160301</enddate><creator>Aras, Nadir</creator><creator>Yalçın, Şerife</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20160301</creationdate><title>Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying</title><author>Aras, Nadir ; Yalçın, Şerife</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c478t-7a25be33beb0bafd281d280f6976893856c7d29dabafa231c8f8bd08e6dec66d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Laser-induced breakdown spectroscopy</topic><topic>Liquid droplet analysis</topic><topic>Oxidized silicon wafer substrate (Si+SiO2)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aras, Nadir</creatorcontrib><creatorcontrib>Yalçın, Şerife</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aras, Nadir</au><au>Yalçın, Şerife</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2016-03-01</date><risdate>2016</risdate><volume>149</volume><spage>53</spage><epage>61</epage><pages>53-61</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3pg Cu, 3.3pg Mn, 79pg Cd and 48pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology. [Display omitted] •A laser induced breakdown method on direct analysis of dried droplets is described.•300nm thick oxide coated silicon wafer (Si+SiO2) was used as a substrate.•Energetic laser pulses are focused onto the droplets, at the out of focus condition.•Measurements indicate 7 times enhancement in S/N for Cu(I) line at 324.75nm.•Technique can identify pg amounts of toxic elements in aqueous environments.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>26717813</pmid><doi>10.1016/j.talanta.2015.11.031</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2016-03, Vol.149, p.53-61
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1753008043
source Elsevier ScienceDirect Journals
subjects Laser-induced breakdown spectroscopy
Liquid droplet analysis
Oxidized silicon wafer substrate (Si+SiO2)
title Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T18%3A34%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20validation%20of%20a%20laser-induced%20breakdown%20spectroscopic%20method%20for%20ultra-trace%20determination%20of%20Cu,%20Mn,%20Cd%20and%20Pb%20metals%20in%20aqueous%20droplets%20after%20drying&rft.jtitle=Talanta%20(Oxford)&rft.au=Aras,%20Nadir&rft.date=2016-03-01&rft.volume=149&rft.spage=53&rft.epage=61&rft.pages=53-61&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2015.11.031&rft_dat=%3Cproquest_cross%3E1753008043%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1753008043&rft_id=info:pmid/26717813&rft_els_id=S0039914015304860&rfr_iscdi=true