Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model

Thermal insulation is one of the most effective energy-conservation measures in buildings. Despite the widespread use of insulation materials in recent years, little is known regarding their optimum thickness under dynamic thermal conditions. Insulated concrete blocks are among the units most common...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied energy 2005-12, Vol.82 (4), p.313-330
Hauptverfasser: Al-Sanea, Sami A., Zedan, M.F., Al-Ajlan, Saleh A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 330
container_issue 4
container_start_page 313
container_title Applied energy
container_volume 82
creator Al-Sanea, Sami A.
Zedan, M.F.
Al-Ajlan, Saleh A.
description Thermal insulation is one of the most effective energy-conservation measures in buildings. Despite the widespread use of insulation materials in recent years, little is known regarding their optimum thickness under dynamic thermal conditions. Insulated concrete blocks are among the units most commonly used in the construction of building walls in Saudi Arabia. Typically, the insulation layer thickness is fixed at a value in the range 2.5–7.5 cm, regardless of the climatic conditions, type and cost of insulation material, and other economic parameters. In the present study, a numerical model based on a finite-volume, time-dependent implicit procedure, which has been previously validated, is used to compute the yearly cooling and heating transmission loads under steady periodic conditions through a typical building wall, for different insulation thicknesses. The transmission loads, calculated by using the climatic conditions of Riyadh for a west-facing wall, are fed into an economic model in order to determine the optimum thickness of insulation ( L opt). The latter corresponds to the minimum total cost, which includes the cost of insulation material and its installation plus the present value of energy consumption cost over the lifetime of the building. The optimum insulation thickness depends on the electricity tariff as well as the cost of insulation material, lifetime of the building, inflation and discount rates, and coefficient of performance of the air-conditioning equipment. In the present study, the effect of electricity tariff on the computed optimum insulation thickness is investigated. Different average electricity tariffs are considered; namely, 0.05, 0.1, 0.2, 0.3 and 0.4 SR/kWh (designated as Cases 1–5, respectively; 1 US$ = 3.75 Saudi Riyals). Results using moulded polystyrene as an insulating material show that the values of L opt are: 4.8, 7.2, 10.9, 13.7 and 16.0 cm for Cases 1–5. Under the conditions of optimal insulation thickness for each electricity tariff, Case 1 gives the lowest total cost of 17.4 SR/m 2, while Case 5 gives the highest total cost of 53.1 SR/m 2. Corresponding thermal performance characteristics in terms of yearly total and peak transmission loads, R-value, time lag and decrement factor are presented.
doi_str_mv 10.1016/j.apenergy.2004.10.014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17447886</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0306261904001965</els_id><sourcerecordid>17447886</sourcerecordid><originalsourceid>FETCH-LOGICAL-c506t-ddd3cb07739d2da9addff77a25bfc1e28be59fca3a85bd80b022fb63bd885c3</originalsourceid><addsrcrecordid>eNqFUcuO1DAQjBBIDAu_gHyBWwY_8pobaLW8tBIHuFsdu73jwXGC7SzKkT-nR7PAkUN1t1pVrVJ1Vb0UfC-46N6c9rBgxHS37SXnDS33XDSPqp0YelkfhBgeVzuueFfLThyeVs9yPnHOpZB8V_26cQ5NYbNjGGhI3viysQLJO8fmyMoR2bwUP60T8zGvAYqfY12O3nyPmDMt2bj6YH28Yz8hhMwgM4sF0-QjWjZuDJjdIkzesCNCqUuCmB0mNs0Ww_PqiYOQ8cVDv6q-vr_5dv2xvv3y4dP1u9vatLwrtbVWmZH3vTpYaeEA1jrX9yDb0RmBchixPTgDCoZ2tAMfuZRu7BTNQ2vUVfX6cnVJ848Vc9GTzwZDgIjzmrXom6Yfho6I3YVo0pxzQqeX5CdImxZcn_PWJ_0nb33O-7ynvEn4-SJMuKD5q0JEWM58fa_Jm6SyEUjZUvOEhrAQlFBaKa6PZaJjrx7sQjYQHCVmfP5npRf0y4ET7-2Fh5Tcvceks_EYDVqf6Jvazv5_vn8Dk9K3Jg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17447886</pqid></control><display><type>article</type><title>Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model</title><source>RePEc</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Al-Sanea, Sami A. ; Zedan, M.F. ; Al-Ajlan, Saleh A.</creator><creatorcontrib>Al-Sanea, Sami A. ; Zedan, M.F. ; Al-Ajlan, Saleh A.</creatorcontrib><description>Thermal insulation is one of the most effective energy-conservation measures in buildings. Despite the widespread use of insulation materials in recent years, little is known regarding their optimum thickness under dynamic thermal conditions. Insulated concrete blocks are among the units most commonly used in the construction of building walls in Saudi Arabia. Typically, the insulation layer thickness is fixed at a value in the range 2.5–7.5 cm, regardless of the climatic conditions, type and cost of insulation material, and other economic parameters. In the present study, a numerical model based on a finite-volume, time-dependent implicit procedure, which has been previously validated, is used to compute the yearly cooling and heating transmission loads under steady periodic conditions through a typical building wall, for different insulation thicknesses. The transmission loads, calculated by using the climatic conditions of Riyadh for a west-facing wall, are fed into an economic model in order to determine the optimum thickness of insulation ( L opt). The latter corresponds to the minimum total cost, which includes the cost of insulation material and its installation plus the present value of energy consumption cost over the lifetime of the building. The optimum insulation thickness depends on the electricity tariff as well as the cost of insulation material, lifetime of the building, inflation and discount rates, and coefficient of performance of the air-conditioning equipment. In the present study, the effect of electricity tariff on the computed optimum insulation thickness is investigated. Different average electricity tariffs are considered; namely, 0.05, 0.1, 0.2, 0.3 and 0.4 SR/kWh (designated as Cases 1–5, respectively; 1 US$ = 3.75 Saudi Riyals). Results using moulded polystyrene as an insulating material show that the values of L opt are: 4.8, 7.2, 10.9, 13.7 and 16.0 cm for Cases 1–5. Under the conditions of optimal insulation thickness for each electricity tariff, Case 1 gives the lowest total cost of 17.4 SR/m 2, while Case 5 gives the highest total cost of 53.1 SR/m 2. Corresponding thermal performance characteristics in terms of yearly total and peak transmission loads, R-value, time lag and decrement factor are presented.</description><identifier>ISSN: 0306-2619</identifier><identifier>EISSN: 1872-9118</identifier><identifier>DOI: 10.1016/j.apenergy.2004.10.014</identifier><identifier>CODEN: APENDX</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Dynamic heat-transmission ; Electricity tariff ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Heat transfer ; Insulated building walls ; Insulated building walls Optimum insulation-thickness Dynamic heat-transmission R-value Electricity tariff ; Optimum insulation-thickness ; R-value ; Theoretical studies. Data and constants. Metering</subject><ispartof>Applied energy, 2005-12, Vol.82 (4), p.313-330</ispartof><rights>2004 Elsevier Ltd</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c506t-ddd3cb07739d2da9addff77a25bfc1e28be59fca3a85bd80b022fb63bd885c3</citedby><cites>FETCH-LOGICAL-c506t-ddd3cb07739d2da9addff77a25bfc1e28be59fca3a85bd80b022fb63bd885c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apenergy.2004.10.014$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,3994,27905,27906,45976</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17126180$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttp://econpapers.repec.org/article/eeeappene/v_3a82_3ay_3a2005_3ai_3a4_3ap_3a313-330.htm$$DView record in RePEc$$Hfree_for_read</backlink></links><search><creatorcontrib>Al-Sanea, Sami A.</creatorcontrib><creatorcontrib>Zedan, M.F.</creatorcontrib><creatorcontrib>Al-Ajlan, Saleh A.</creatorcontrib><title>Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model</title><title>Applied energy</title><description>Thermal insulation is one of the most effective energy-conservation measures in buildings. Despite the widespread use of insulation materials in recent years, little is known regarding their optimum thickness under dynamic thermal conditions. Insulated concrete blocks are among the units most commonly used in the construction of building walls in Saudi Arabia. Typically, the insulation layer thickness is fixed at a value in the range 2.5–7.5 cm, regardless of the climatic conditions, type and cost of insulation material, and other economic parameters. In the present study, a numerical model based on a finite-volume, time-dependent implicit procedure, which has been previously validated, is used to compute the yearly cooling and heating transmission loads under steady periodic conditions through a typical building wall, for different insulation thicknesses. The transmission loads, calculated by using the climatic conditions of Riyadh for a west-facing wall, are fed into an economic model in order to determine the optimum thickness of insulation ( L opt). The latter corresponds to the minimum total cost, which includes the cost of insulation material and its installation plus the present value of energy consumption cost over the lifetime of the building. The optimum insulation thickness depends on the electricity tariff as well as the cost of insulation material, lifetime of the building, inflation and discount rates, and coefficient of performance of the air-conditioning equipment. In the present study, the effect of electricity tariff on the computed optimum insulation thickness is investigated. Different average electricity tariffs are considered; namely, 0.05, 0.1, 0.2, 0.3 and 0.4 SR/kWh (designated as Cases 1–5, respectively; 1 US$ = 3.75 Saudi Riyals). Results using moulded polystyrene as an insulating material show that the values of L opt are: 4.8, 7.2, 10.9, 13.7 and 16.0 cm for Cases 1–5. Under the conditions of optimal insulation thickness for each electricity tariff, Case 1 gives the lowest total cost of 17.4 SR/m 2, while Case 5 gives the highest total cost of 53.1 SR/m 2. Corresponding thermal performance characteristics in terms of yearly total and peak transmission loads, R-value, time lag and decrement factor are presented.</description><subject>Applied sciences</subject><subject>Dynamic heat-transmission</subject><subject>Electricity tariff</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Heat transfer</subject><subject>Insulated building walls</subject><subject>Insulated building walls Optimum insulation-thickness Dynamic heat-transmission R-value Electricity tariff</subject><subject>Optimum insulation-thickness</subject><subject>R-value</subject><subject>Theoretical studies. Data and constants. Metering</subject><issn>0306-2619</issn><issn>1872-9118</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>X2L</sourceid><recordid>eNqFUcuO1DAQjBBIDAu_gHyBWwY_8pobaLW8tBIHuFsdu73jwXGC7SzKkT-nR7PAkUN1t1pVrVJ1Vb0UfC-46N6c9rBgxHS37SXnDS33XDSPqp0YelkfhBgeVzuueFfLThyeVs9yPnHOpZB8V_26cQ5NYbNjGGhI3viysQLJO8fmyMoR2bwUP60T8zGvAYqfY12O3nyPmDMt2bj6YH28Yz8hhMwgM4sF0-QjWjZuDJjdIkzesCNCqUuCmB0mNs0Ww_PqiYOQ8cVDv6q-vr_5dv2xvv3y4dP1u9vatLwrtbVWmZH3vTpYaeEA1jrX9yDb0RmBchixPTgDCoZ2tAMfuZRu7BTNQ2vUVfX6cnVJ848Vc9GTzwZDgIjzmrXom6Yfho6I3YVo0pxzQqeX5CdImxZcn_PWJ_0nb33O-7ynvEn4-SJMuKD5q0JEWM58fa_Jm6SyEUjZUvOEhrAQlFBaKa6PZaJjrx7sQjYQHCVmfP5npRf0y4ET7-2Fh5Tcvceks_EYDVqf6Jvazv5_vn8Dk9K3Jg</recordid><startdate>20051201</startdate><enddate>20051201</enddate><creator>Al-Sanea, Sami A.</creator><creator>Zedan, M.F.</creator><creator>Al-Ajlan, Saleh A.</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><general>Elsevier</general><scope>IQODW</scope><scope>DKI</scope><scope>X2L</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7U6</scope><scope>C1K</scope></search><sort><creationdate>20051201</creationdate><title>Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model</title><author>Al-Sanea, Sami A. ; Zedan, M.F. ; Al-Ajlan, Saleh A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c506t-ddd3cb07739d2da9addff77a25bfc1e28be59fca3a85bd80b022fb63bd885c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Applied sciences</topic><topic>Dynamic heat-transmission</topic><topic>Electricity tariff</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Heat transfer</topic><topic>Insulated building walls</topic><topic>Insulated building walls Optimum insulation-thickness Dynamic heat-transmission R-value Electricity tariff</topic><topic>Optimum insulation-thickness</topic><topic>R-value</topic><topic>Theoretical studies. Data and constants. Metering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al-Sanea, Sami A.</creatorcontrib><creatorcontrib>Zedan, M.F.</creatorcontrib><creatorcontrib>Al-Ajlan, Saleh A.</creatorcontrib><collection>Pascal-Francis</collection><collection>RePEc IDEAS</collection><collection>RePEc</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Applied energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Sanea, Sami A.</au><au>Zedan, M.F.</au><au>Al-Ajlan, Saleh A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model</atitle><jtitle>Applied energy</jtitle><date>2005-12-01</date><risdate>2005</risdate><volume>82</volume><issue>4</issue><spage>313</spage><epage>330</epage><pages>313-330</pages><issn>0306-2619</issn><eissn>1872-9118</eissn><coden>APENDX</coden><abstract>Thermal insulation is one of the most effective energy-conservation measures in buildings. Despite the widespread use of insulation materials in recent years, little is known regarding their optimum thickness under dynamic thermal conditions. Insulated concrete blocks are among the units most commonly used in the construction of building walls in Saudi Arabia. Typically, the insulation layer thickness is fixed at a value in the range 2.5–7.5 cm, regardless of the climatic conditions, type and cost of insulation material, and other economic parameters. In the present study, a numerical model based on a finite-volume, time-dependent implicit procedure, which has been previously validated, is used to compute the yearly cooling and heating transmission loads under steady periodic conditions through a typical building wall, for different insulation thicknesses. The transmission loads, calculated by using the climatic conditions of Riyadh for a west-facing wall, are fed into an economic model in order to determine the optimum thickness of insulation ( L opt). The latter corresponds to the minimum total cost, which includes the cost of insulation material and its installation plus the present value of energy consumption cost over the lifetime of the building. The optimum insulation thickness depends on the electricity tariff as well as the cost of insulation material, lifetime of the building, inflation and discount rates, and coefficient of performance of the air-conditioning equipment. In the present study, the effect of electricity tariff on the computed optimum insulation thickness is investigated. Different average electricity tariffs are considered; namely, 0.05, 0.1, 0.2, 0.3 and 0.4 SR/kWh (designated as Cases 1–5, respectively; 1 US$ = 3.75 Saudi Riyals). Results using moulded polystyrene as an insulating material show that the values of L opt are: 4.8, 7.2, 10.9, 13.7 and 16.0 cm for Cases 1–5. Under the conditions of optimal insulation thickness for each electricity tariff, Case 1 gives the lowest total cost of 17.4 SR/m 2, while Case 5 gives the highest total cost of 53.1 SR/m 2. Corresponding thermal performance characteristics in terms of yearly total and peak transmission loads, R-value, time lag and decrement factor are presented.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.apenergy.2004.10.014</doi><tpages>18</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0306-2619
ispartof Applied energy, 2005-12, Vol.82 (4), p.313-330
issn 0306-2619
1872-9118
language eng
recordid cdi_proquest_miscellaneous_17447886
source RePEc; ScienceDirect Journals (5 years ago - present)
subjects Applied sciences
Dynamic heat-transmission
Electricity tariff
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Heat transfer
Insulated building walls
Insulated building walls Optimum insulation-thickness Dynamic heat-transmission R-value Electricity tariff
Optimum insulation-thickness
R-value
Theoretical studies. Data and constants. Metering
title Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T16%3A29%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20electricity%20tariff%20on%20the%20optimum%20insulation-thickness%20in%20building%20walls%20as%20determined%20by%20a%20dynamic%20heat-transfer%20model&rft.jtitle=Applied%20energy&rft.au=Al-Sanea,%20Sami%20A.&rft.date=2005-12-01&rft.volume=82&rft.issue=4&rft.spage=313&rft.epage=330&rft.pages=313-330&rft.issn=0306-2619&rft.eissn=1872-9118&rft.coden=APENDX&rft_id=info:doi/10.1016/j.apenergy.2004.10.014&rft_dat=%3Cproquest_cross%3E17447886%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17447886&rft_id=info:pmid/&rft_els_id=S0306261904001965&rfr_iscdi=true