A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence

A simple and fast method for the multi-elemental determination of 18 inorganic constituents (P, S, Cl, K, Ca, Ti, Cr, V, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb) in organic fertilizers employing slurry sampling and total reflection X-ray fluorescence (TXRF) is presented. A 23 factorial design with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2016-01, Vol.147, p.485-492
Hauptverfasser: Resende, Luciene V., Nascentes, Clésia C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 492
container_issue
container_start_page 485
container_title Talanta (Oxford)
container_volume 147
creator Resende, Luciene V.
Nascentes, Clésia C.
description A simple and fast method for the multi-elemental determination of 18 inorganic constituents (P, S, Cl, K, Ca, Ti, Cr, V, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb) in organic fertilizers employing slurry sampling and total reflection X-ray fluorescence (TXRF) is presented. A 23 factorial design with a central point was employed to optimize the slurry sampling procedure. The internal standard and instrumental conditions were optimized by univariate studies. The selectivity of the method to determining Se, As, Pb, Cr, Ni and Cd was assessed. The accuracy was evaluated by the analysis of four standard reference materials (SRM). The recoveries varied from 72% to 114%. For most of the elements, good agreement was achieved between the certified value and the value measured in the SRM. The relative standard deviation (RSD %) ranged from 0.5% to 14%. The evaluated method was applied to the determination of analytes in the press cake of palm, castor, curcas, sunflower, fodder turnip, white lupin, rapeseed and pequi, and their potential to be used as organic fertilizer was evaluated in accordance with Brazilian legislation. [Display omitted] •A simple and fast method to determine 18 analytes in organic fertilizers.•TXRF is a powerful technique to multi-elemental analysis.•Slurry sampling is a good alternative procedure to acid digestion.•Optimized method presented an adequate analytical performance.•Proposed method can be employed for organic fertilizers quality control.
doi_str_mv 10.1016/j.talanta.2015.10.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1735909715</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S003991401530374X</els_id><sourcerecordid>1735909715</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412t-e57f9bfeb64dfc84b2437220c64cb42225961c21730cd3066a745808a7bb5c093</originalsourceid><addsrcrecordid>eNqFkE9v1DAQxS0EokvLRwD5yCXL2I7jzQlVVfkjVeJSpN4sxxm3XjnxYjtIy63fHEe7cOU0mtF782Z-hLxjsGXAuo_7bTHBzMVsOTBZZ1sA9YJs2E6JRkglXpINgOibnrVwQd7kvAcALkC8Jhe8kz3vhNqQ52ua_XQISCcsT3GkLiZanmq7hOIbDDhhDQnUzCYcs880OhrTo5m9pQ5T8cH_xkSHI81hSakWU9f5-bE6Rlri6k3oAtri40wfmmSO1IUlJswWZ4tX5JUzIePbc70kPz7f3t98be6-f_l2c33X2Jbx0qBUrh8cDl07OrtrB94KxTnYrrVDyzmXfccsZ0qAHQV0nVGt3MHOqGGQFnpxST6c9h5S_LlgLnry9YJQIWJcsq5O2UOvmKxSeZLaFHOu1-tD8pNJR81Ar_T1Xp_p65X-Oq70q-_9OWIZJhz_uf7iroJPJwHWR395TDpbv0IYfaqA9Bj9fyL-AFl3mpQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1735909715</pqid></control><display><type>article</type><title>A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Resende, Luciene V. ; Nascentes, Clésia C.</creator><creatorcontrib>Resende, Luciene V. ; Nascentes, Clésia C.</creatorcontrib><description>A simple and fast method for the multi-elemental determination of 18 inorganic constituents (P, S, Cl, K, Ca, Ti, Cr, V, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb) in organic fertilizers employing slurry sampling and total reflection X-ray fluorescence (TXRF) is presented. A 23 factorial design with a central point was employed to optimize the slurry sampling procedure. The internal standard and instrumental conditions were optimized by univariate studies. The selectivity of the method to determining Se, As, Pb, Cr, Ni and Cd was assessed. The accuracy was evaluated by the analysis of four standard reference materials (SRM). The recoveries varied from 72% to 114%. For most of the elements, good agreement was achieved between the certified value and the value measured in the SRM. The relative standard deviation (RSD %) ranged from 0.5% to 14%. The evaluated method was applied to the determination of analytes in the press cake of palm, castor, curcas, sunflower, fodder turnip, white lupin, rapeseed and pequi, and their potential to be used as organic fertilizer was evaluated in accordance with Brazilian legislation. [Display omitted] •A simple and fast method to determine 18 analytes in organic fertilizers.•TXRF is a powerful technique to multi-elemental analysis.•Slurry sampling is a good alternative procedure to acid digestion.•Optimized method presented an adequate analytical performance.•Proposed method can be employed for organic fertilizers quality control.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2015.10.007</identifier><identifier>PMID: 26592637</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Biodiesel by-products ; Biofuels ; Bromine - analysis ; Chlorine - analysis ; Fertilizers - analysis ; Magnoliopsida ; Metals - analysis ; Organic fertilizer ; Phosphorus - analysis ; Press cake ; Seeds ; Slurry sampling ; Spectrometry, X-Ray Emission ; Sulfur - analysis ; TXRF ; Waste Products - analysis</subject><ispartof>Talanta (Oxford), 2016-01, Vol.147, p.485-492</ispartof><rights>2015 Elsevier B.V.</rights><rights>Copyright © 2015 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412t-e57f9bfeb64dfc84b2437220c64cb42225961c21730cd3066a745808a7bb5c093</citedby><cites>FETCH-LOGICAL-c412t-e57f9bfeb64dfc84b2437220c64cb42225961c21730cd3066a745808a7bb5c093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.talanta.2015.10.007$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>315,781,785,3551,27929,27930,46000</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26592637$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Resende, Luciene V.</creatorcontrib><creatorcontrib>Nascentes, Clésia C.</creatorcontrib><title>A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A simple and fast method for the multi-elemental determination of 18 inorganic constituents (P, S, Cl, K, Ca, Ti, Cr, V, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb) in organic fertilizers employing slurry sampling and total reflection X-ray fluorescence (TXRF) is presented. A 23 factorial design with a central point was employed to optimize the slurry sampling procedure. The internal standard and instrumental conditions were optimized by univariate studies. The selectivity of the method to determining Se, As, Pb, Cr, Ni and Cd was assessed. The accuracy was evaluated by the analysis of four standard reference materials (SRM). The recoveries varied from 72% to 114%. For most of the elements, good agreement was achieved between the certified value and the value measured in the SRM. The relative standard deviation (RSD %) ranged from 0.5% to 14%. The evaluated method was applied to the determination of analytes in the press cake of palm, castor, curcas, sunflower, fodder turnip, white lupin, rapeseed and pequi, and their potential to be used as organic fertilizer was evaluated in accordance with Brazilian legislation. [Display omitted] •A simple and fast method to determine 18 analytes in organic fertilizers.•TXRF is a powerful technique to multi-elemental analysis.•Slurry sampling is a good alternative procedure to acid digestion.•Optimized method presented an adequate analytical performance.•Proposed method can be employed for organic fertilizers quality control.</description><subject>Biodiesel by-products</subject><subject>Biofuels</subject><subject>Bromine - analysis</subject><subject>Chlorine - analysis</subject><subject>Fertilizers - analysis</subject><subject>Magnoliopsida</subject><subject>Metals - analysis</subject><subject>Organic fertilizer</subject><subject>Phosphorus - analysis</subject><subject>Press cake</subject><subject>Seeds</subject><subject>Slurry sampling</subject><subject>Spectrometry, X-Ray Emission</subject><subject>Sulfur - analysis</subject><subject>TXRF</subject><subject>Waste Products - analysis</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE9v1DAQxS0EokvLRwD5yCXL2I7jzQlVVfkjVeJSpN4sxxm3XjnxYjtIy63fHEe7cOU0mtF782Z-hLxjsGXAuo_7bTHBzMVsOTBZZ1sA9YJs2E6JRkglXpINgOibnrVwQd7kvAcALkC8Jhe8kz3vhNqQ52ua_XQISCcsT3GkLiZanmq7hOIbDDhhDQnUzCYcs880OhrTo5m9pQ5T8cH_xkSHI81hSakWU9f5-bE6Rlri6k3oAtri40wfmmSO1IUlJswWZ4tX5JUzIePbc70kPz7f3t98be6-f_l2c33X2Jbx0qBUrh8cDl07OrtrB94KxTnYrrVDyzmXfccsZ0qAHQV0nVGt3MHOqGGQFnpxST6c9h5S_LlgLnry9YJQIWJcsq5O2UOvmKxSeZLaFHOu1-tD8pNJR81Ar_T1Xp_p65X-Oq70q-_9OWIZJhz_uf7iroJPJwHWR395TDpbv0IYfaqA9Bj9fyL-AFl3mpQ</recordid><startdate>20160115</startdate><enddate>20160115</enddate><creator>Resende, Luciene V.</creator><creator>Nascentes, Clésia C.</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20160115</creationdate><title>A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence</title><author>Resende, Luciene V. ; Nascentes, Clésia C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412t-e57f9bfeb64dfc84b2437220c64cb42225961c21730cd3066a745808a7bb5c093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Biodiesel by-products</topic><topic>Biofuels</topic><topic>Bromine - analysis</topic><topic>Chlorine - analysis</topic><topic>Fertilizers - analysis</topic><topic>Magnoliopsida</topic><topic>Metals - analysis</topic><topic>Organic fertilizer</topic><topic>Phosphorus - analysis</topic><topic>Press cake</topic><topic>Seeds</topic><topic>Slurry sampling</topic><topic>Spectrometry, X-Ray Emission</topic><topic>Sulfur - analysis</topic><topic>TXRF</topic><topic>Waste Products - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Resende, Luciene V.</creatorcontrib><creatorcontrib>Nascentes, Clésia C.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Resende, Luciene V.</au><au>Nascentes, Clésia C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2016-01-15</date><risdate>2016</risdate><volume>147</volume><spage>485</spage><epage>492</epage><pages>485-492</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>A simple and fast method for the multi-elemental determination of 18 inorganic constituents (P, S, Cl, K, Ca, Ti, Cr, V, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba and Pb) in organic fertilizers employing slurry sampling and total reflection X-ray fluorescence (TXRF) is presented. A 23 factorial design with a central point was employed to optimize the slurry sampling procedure. The internal standard and instrumental conditions were optimized by univariate studies. The selectivity of the method to determining Se, As, Pb, Cr, Ni and Cd was assessed. The accuracy was evaluated by the analysis of four standard reference materials (SRM). The recoveries varied from 72% to 114%. For most of the elements, good agreement was achieved between the certified value and the value measured in the SRM. The relative standard deviation (RSD %) ranged from 0.5% to 14%. The evaluated method was applied to the determination of analytes in the press cake of palm, castor, curcas, sunflower, fodder turnip, white lupin, rapeseed and pequi, and their potential to be used as organic fertilizer was evaluated in accordance with Brazilian legislation. [Display omitted] •A simple and fast method to determine 18 analytes in organic fertilizers.•TXRF is a powerful technique to multi-elemental analysis.•Slurry sampling is a good alternative procedure to acid digestion.•Optimized method presented an adequate analytical performance.•Proposed method can be employed for organic fertilizers quality control.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>26592637</pmid><doi>10.1016/j.talanta.2015.10.007</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2016-01, Vol.147, p.485-492
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1735909715
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Biodiesel by-products
Biofuels
Bromine - analysis
Chlorine - analysis
Fertilizers - analysis
Magnoliopsida
Metals - analysis
Organic fertilizer
Phosphorus - analysis
Press cake
Seeds
Slurry sampling
Spectrometry, X-Ray Emission
Sulfur - analysis
TXRF
Waste Products - analysis
title A simple method for the multi-elemental analysis of organic fertilizer by slurry sampling and total reflection X-ray fluorescence
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-13T10%3A38%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20simple%20method%20for%20the%20multi-elemental%20analysis%20of%20organic%20fertilizer%20by%20slurry%20sampling%20and%20total%20reflection%20X-ray%20fluorescence&rft.jtitle=Talanta%20(Oxford)&rft.au=Resende,%20Luciene%20V.&rft.date=2016-01-15&rft.volume=147&rft.spage=485&rft.epage=492&rft.pages=485-492&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2015.10.007&rft_dat=%3Cproquest_cross%3E1735909715%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1735909715&rft_id=info:pmid/26592637&rft_els_id=S003991401530374X&rfr_iscdi=true