Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems
To compare the bond strength and the fracture resistance of different post systems. Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to t...
Gespeichert in:
Veröffentlicht in: | The journal of contemporary dental practice 2015-10, Vol.16 (10), p.788-793 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 793 |
---|---|
container_issue | 10 |
container_start_page | 788 |
container_title | The journal of contemporary dental practice |
container_volume | 16 |
creator | Türker, Sevinç Aktemur Özçelik, Bahar Yilmaz, Zeliha |
description | To compare the bond strength and the fracture resistance of different post systems.
Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to the posts used zirconia posts (ZR post), individually formed glass fiber reinforced composite posts with an (Interpenetrating Polymer Network-IPN post) and cast metal posts. Then groups were randomly assigned into two subgroups according to the post design: 1-parallel sided and 2-tapered (n = 10/group). All posts were luted with a self-adhesive luting agent. For push-out test two 1 mm thick horizontal root sections were obtained and subjected to push-out test. For fracture resistance test, the specimens were loaded vertically at 1 mm/min crosshead speed. The push out test data were analyzed with Kruskal-Wallis and Dunn's test. Analysis of variance (ANOVA) and Tukey significant difference tests were used to compare the fracture resistance.
Cast metal posts showed the highest retention (p < 0.05); however, IPN and zirconia posts showed similar results. No significant difference was found between parallel sided or tapered designs of post groups in terms of bond strength (p > 0.05). In terms of fracture resistance, IPN post groups showed lowest fracture resistance (p < 0.05). No significant difference was found between parallel sided or tapered posts in terms of fracture resistance, except zirconia post (p > 0.05). There was no relationship between the bond strength and fracture resistance of the post systems (r = - 0.015, p > 0.700).
Post type had effect both on the fracture resistance and retention of the posts used. However, post design had effect only on the fracture resistance of the post systems.
Superficial treatment of the post used can improve the retention of post systems. |
doi_str_mv | 10.5005/JP-JOURNALS-10024-1758 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1735325941</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1735325941</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2748-656aa846166734252a36b1fee0f8e12f2a0cde2778ad9eb664c31d6cedd02bc13</originalsourceid><addsrcrecordid>eNpNkE1PwkAQhjdGI4j-BdKjl-p-dHfLERFUQgRBzpvtdiolpcXdrQn_3lbQeJqZ5HlnJg9CfYLvOMb8froIp_P18nU4W4UEYxqFRPL4DHUJpyJkkpDzf30HXTm3bTBGJb5EHSp4TCIed9Hb-EsXtfZ5VQZVFvgNBA9VmQYrb6H88JtAN8PEauNrC8ESXO68Lg208GOeZdBgPlhUzgerg_Owc9foItOFg5tT7aH1ZPw-eg5n86eX0XAWGiqjOBRcaB1HggghWUQ51UwkJAPAWQyEZlRjkwKVMtbpABIhIsNIKgykKaaJIayHbo9797b6rMF5tcudgaLQJVS1U0QyzigfRC0qjqixlXMWMrW3-U7bgyJYtTrVdq-2VW3L5mH1o1O1Optg_3SjTnaQ_sV-_bFvVNxzCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1735325941</pqid></control><display><type>article</type><title>Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Türker, Sevinç Aktemur ; Özçelik, Bahar ; Yilmaz, Zeliha</creator><creatorcontrib>Türker, Sevinç Aktemur ; Özçelik, Bahar ; Yilmaz, Zeliha</creatorcontrib><description>To compare the bond strength and the fracture resistance of different post systems.
Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to the posts used zirconia posts (ZR post), individually formed glass fiber reinforced composite posts with an (Interpenetrating Polymer Network-IPN post) and cast metal posts. Then groups were randomly assigned into two subgroups according to the post design: 1-parallel sided and 2-tapered (n = 10/group). All posts were luted with a self-adhesive luting agent. For push-out test two 1 mm thick horizontal root sections were obtained and subjected to push-out test. For fracture resistance test, the specimens were loaded vertically at 1 mm/min crosshead speed. The push out test data were analyzed with Kruskal-Wallis and Dunn's test. Analysis of variance (ANOVA) and Tukey significant difference tests were used to compare the fracture resistance.
Cast metal posts showed the highest retention (p < 0.05); however, IPN and zirconia posts showed similar results. No significant difference was found between parallel sided or tapered designs of post groups in terms of bond strength (p > 0.05). In terms of fracture resistance, IPN post groups showed lowest fracture resistance (p < 0.05). No significant difference was found between parallel sided or tapered posts in terms of fracture resistance, except zirconia post (p > 0.05). There was no relationship between the bond strength and fracture resistance of the post systems (r = - 0.015, p > 0.700).
Post type had effect both on the fracture resistance and retention of the posts used. However, post design had effect only on the fracture resistance of the post systems.
Superficial treatment of the post used can improve the retention of post systems.</description><identifier>ISSN: 1526-3711</identifier><identifier>EISSN: 1526-3711</identifier><identifier>DOI: 10.5005/JP-JOURNALS-10024-1758</identifier><identifier>PMID: 26581458</identifier><language>eng</language><publisher>India</publisher><subject>Composite Resins ; Dental Bonding ; Dental Stress Analysis ; Dentistry ; Glass ; Humans ; Incisor ; Materials Testing ; Post and Core Technique ; Resin Cements ; Tooth Root</subject><ispartof>The journal of contemporary dental practice, 2015-10, Vol.16 (10), p.788-793</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2748-656aa846166734252a36b1fee0f8e12f2a0cde2778ad9eb664c31d6cedd02bc13</citedby><cites>FETCH-LOGICAL-c2748-656aa846166734252a36b1fee0f8e12f2a0cde2778ad9eb664c31d6cedd02bc13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26581458$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Türker, Sevinç Aktemur</creatorcontrib><creatorcontrib>Özçelik, Bahar</creatorcontrib><creatorcontrib>Yilmaz, Zeliha</creatorcontrib><title>Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems</title><title>The journal of contemporary dental practice</title><addtitle>J Contemp Dent Pract</addtitle><description>To compare the bond strength and the fracture resistance of different post systems.
Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to the posts used zirconia posts (ZR post), individually formed glass fiber reinforced composite posts with an (Interpenetrating Polymer Network-IPN post) and cast metal posts. Then groups were randomly assigned into two subgroups according to the post design: 1-parallel sided and 2-tapered (n = 10/group). All posts were luted with a self-adhesive luting agent. For push-out test two 1 mm thick horizontal root sections were obtained and subjected to push-out test. For fracture resistance test, the specimens were loaded vertically at 1 mm/min crosshead speed. The push out test data were analyzed with Kruskal-Wallis and Dunn's test. Analysis of variance (ANOVA) and Tukey significant difference tests were used to compare the fracture resistance.
Cast metal posts showed the highest retention (p < 0.05); however, IPN and zirconia posts showed similar results. No significant difference was found between parallel sided or tapered designs of post groups in terms of bond strength (p > 0.05). In terms of fracture resistance, IPN post groups showed lowest fracture resistance (p < 0.05). No significant difference was found between parallel sided or tapered posts in terms of fracture resistance, except zirconia post (p > 0.05). There was no relationship between the bond strength and fracture resistance of the post systems (r = - 0.015, p > 0.700).
Post type had effect both on the fracture resistance and retention of the posts used. However, post design had effect only on the fracture resistance of the post systems.
Superficial treatment of the post used can improve the retention of post systems.</description><subject>Composite Resins</subject><subject>Dental Bonding</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Glass</subject><subject>Humans</subject><subject>Incisor</subject><subject>Materials Testing</subject><subject>Post and Core Technique</subject><subject>Resin Cements</subject><subject>Tooth Root</subject><issn>1526-3711</issn><issn>1526-3711</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkE1PwkAQhjdGI4j-BdKjl-p-dHfLERFUQgRBzpvtdiolpcXdrQn_3lbQeJqZ5HlnJg9CfYLvOMb8froIp_P18nU4W4UEYxqFRPL4DHUJpyJkkpDzf30HXTm3bTBGJb5EHSp4TCIed9Hb-EsXtfZ5VQZVFvgNBA9VmQYrb6H88JtAN8PEauNrC8ESXO68Lg208GOeZdBgPlhUzgerg_Owc9foItOFg5tT7aH1ZPw-eg5n86eX0XAWGiqjOBRcaB1HggghWUQ51UwkJAPAWQyEZlRjkwKVMtbpABIhIsNIKgykKaaJIayHbo9797b6rMF5tcudgaLQJVS1U0QyzigfRC0qjqixlXMWMrW3-U7bgyJYtTrVdq-2VW3L5mH1o1O1Optg_3SjTnaQ_sV-_bFvVNxzCg</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>Türker, Sevinç Aktemur</creator><creator>Özçelik, Bahar</creator><creator>Yilmaz, Zeliha</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20151001</creationdate><title>Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems</title><author>Türker, Sevinç Aktemur ; Özçelik, Bahar ; Yilmaz, Zeliha</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2748-656aa846166734252a36b1fee0f8e12f2a0cde2778ad9eb664c31d6cedd02bc13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Composite Resins</topic><topic>Dental Bonding</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Glass</topic><topic>Humans</topic><topic>Incisor</topic><topic>Materials Testing</topic><topic>Post and Core Technique</topic><topic>Resin Cements</topic><topic>Tooth Root</topic><toplevel>online_resources</toplevel><creatorcontrib>Türker, Sevinç Aktemur</creatorcontrib><creatorcontrib>Özçelik, Bahar</creatorcontrib><creatorcontrib>Yilmaz, Zeliha</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The journal of contemporary dental practice</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Türker, Sevinç Aktemur</au><au>Özçelik, Bahar</au><au>Yilmaz, Zeliha</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems</atitle><jtitle>The journal of contemporary dental practice</jtitle><addtitle>J Contemp Dent Pract</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>16</volume><issue>10</issue><spage>788</spage><epage>793</epage><pages>788-793</pages><issn>1526-3711</issn><eissn>1526-3711</eissn><abstract>To compare the bond strength and the fracture resistance of different post systems.
Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to the posts used zirconia posts (ZR post), individually formed glass fiber reinforced composite posts with an (Interpenetrating Polymer Network-IPN post) and cast metal posts. Then groups were randomly assigned into two subgroups according to the post design: 1-parallel sided and 2-tapered (n = 10/group). All posts were luted with a self-adhesive luting agent. For push-out test two 1 mm thick horizontal root sections were obtained and subjected to push-out test. For fracture resistance test, the specimens were loaded vertically at 1 mm/min crosshead speed. The push out test data were analyzed with Kruskal-Wallis and Dunn's test. Analysis of variance (ANOVA) and Tukey significant difference tests were used to compare the fracture resistance.
Cast metal posts showed the highest retention (p < 0.05); however, IPN and zirconia posts showed similar results. No significant difference was found between parallel sided or tapered designs of post groups in terms of bond strength (p > 0.05). In terms of fracture resistance, IPN post groups showed lowest fracture resistance (p < 0.05). No significant difference was found between parallel sided or tapered posts in terms of fracture resistance, except zirconia post (p > 0.05). There was no relationship between the bond strength and fracture resistance of the post systems (r = - 0.015, p > 0.700).
Post type had effect both on the fracture resistance and retention of the posts used. However, post design had effect only on the fracture resistance of the post systems.
Superficial treatment of the post used can improve the retention of post systems.</abstract><cop>India</cop><pmid>26581458</pmid><doi>10.5005/JP-JOURNALS-10024-1758</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1526-3711 |
ispartof | The journal of contemporary dental practice, 2015-10, Vol.16 (10), p.788-793 |
issn | 1526-3711 1526-3711 |
language | eng |
recordid | cdi_proquest_miscellaneous_1735325941 |
source | MEDLINE; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
subjects | Composite Resins Dental Bonding Dental Stress Analysis Dentistry Glass Humans Incisor Materials Testing Post and Core Technique Resin Cements Tooth Root |
title | Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T23%3A06%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Bond%20Strength%20and%20Fracture%20Resistance%20of%20Different%20Post%20Systems&rft.jtitle=The%20journal%20of%20contemporary%20dental%20practice&rft.au=T%C3%BCrker,%20Sevin%C3%A7%20Aktemur&rft.date=2015-10-01&rft.volume=16&rft.issue=10&rft.spage=788&rft.epage=793&rft.pages=788-793&rft.issn=1526-3711&rft.eissn=1526-3711&rft_id=info:doi/10.5005/JP-JOURNALS-10024-1758&rft_dat=%3Cproquest_cross%3E1735325941%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1735325941&rft_id=info:pmid/26581458&rfr_iscdi=true |