Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error

Introduction Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. W...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International orthopaedics 2015-12, Vol.39 (12), p.2347-2353
Hauptverfasser: Forster-Horvath, Csaba, Kremo, Valerie, Müller-Gerbl, Magdalena, Nowakowski, Andrej Maria
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2353
container_issue 12
container_start_page 2347
container_title International orthopaedics
container_volume 39
creator Forster-Horvath, Csaba
Kremo, Valerie
Müller-Gerbl, Magdalena
Nowakowski, Andrej Maria
description Introduction Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. We hypothesise that using the anatomical tibial axis (ATA) to align tibial component rotation on the resected tibial surface may lead to an internal rotation error due to relative anterior shift of the lateral articular surface centre compared to the medial one. The aim of this study was to compare the anatomical tibial axis of the physiological tibial joint surface to the resected one. Method Twenty formalin-fixed cadaveric knees were obtained for study. After computed tomography scanning the data of each specimen were entered into a standardised coordinate system and virtual bone cuts were performed with 6, 8 and 10 mm resection depths. The positions of the articular surface centres were determined at each resection depth. Results The lateral articular surface centre had moved anteriorly after the resection by a mean 1.475 mm, while the medial one had not changed significantly. Resecting the tibia at a 6-mm cut and using the transverse tibial axis to align the prosthetic tibial plateau will result in a mean 4.0° (95 % confidence interval, 2.5-5.5°) of internal rotation compared to the uncut tibia. Discussion The ATA lies in 6 degrees of external rotation compared to the perpendicular to the posterior tibial condylar axis (PTCA). Graw et al. suggest aligning the tibial component in 10 degrees of external rotation to the latter. Thus, if we accept the above suggestion, the ATA is 4 degrees internally rotated compared to the same line on the resected proximal tibia. These prior studies appear to be in accordance with our findings. Conclusions We conclude that using the ATA on the resected tibial surface may contribute to an internal rotation error.
doi_str_mv 10.1007/s00264-015-2858-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1733196145</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1733196145</sourcerecordid><originalsourceid>FETCH-LOGICAL-c523t-543701006f3aafd60cd4808b51a7a9fbc78e275c307e319e3ed5e5a153d5889c3</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EgvL4ADbISzYBTxw_skSIl1SJDawtN5kUQ2IX25Xo3-OqwJLVaDTnXmkOIefAroAxdZ0Yq2VTMRBVrYWu9B6ZQcPrSkAr9smM8QaqWrbiiByn9M4YKKnhkBzVEoRUIGdkek3OL2l-Q2q9zWFynR1pdgtXhv1yiQ4h0hxyWT88FirmtxhWo015Q-3oln5Cn-lkN3RE2xe0FFHnM0ZfMrEkswueYowhnpKDwY4Jz37mCXm9v3u5fazmzw9PtzfzqhM1z5VouGLlQzlwa4desq5vNNMLAVbZdlh0SmOtRMeZQg4tcuwFCguC90LrtuMn5HLXu4rhc40pm8mlDsfRegzrZEDxkpPQiILCDu1iSCniYFbRTTZuDDCztWx2lk2xbLaWjS6Zi5_69WLC_i_xq7UA9Q5I5eSXGM17WG99pH9avwGo_Ijr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1733196145</pqid></control><display><type>article</type><title>Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error</title><source>MEDLINE</source><source>Springer Online Journals Complete</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Forster-Horvath, Csaba ; Kremo, Valerie ; Müller-Gerbl, Magdalena ; Nowakowski, Andrej Maria</creator><creatorcontrib>Forster-Horvath, Csaba ; Kremo, Valerie ; Müller-Gerbl, Magdalena ; Nowakowski, Andrej Maria</creatorcontrib><description>Introduction Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. We hypothesise that using the anatomical tibial axis (ATA) to align tibial component rotation on the resected tibial surface may lead to an internal rotation error due to relative anterior shift of the lateral articular surface centre compared to the medial one. The aim of this study was to compare the anatomical tibial axis of the physiological tibial joint surface to the resected one. Method Twenty formalin-fixed cadaveric knees were obtained for study. After computed tomography scanning the data of each specimen were entered into a standardised coordinate system and virtual bone cuts were performed with 6, 8 and 10 mm resection depths. The positions of the articular surface centres were determined at each resection depth. Results The lateral articular surface centre had moved anteriorly after the resection by a mean 1.475 mm, while the medial one had not changed significantly. Resecting the tibia at a 6-mm cut and using the transverse tibial axis to align the prosthetic tibial plateau will result in a mean 4.0° (95 % confidence interval, 2.5-5.5°) of internal rotation compared to the uncut tibia. Discussion The ATA lies in 6 degrees of external rotation compared to the perpendicular to the posterior tibial condylar axis (PTCA). Graw et al. suggest aligning the tibial component in 10 degrees of external rotation to the latter. Thus, if we accept the above suggestion, the ATA is 4 degrees internally rotated compared to the same line on the resected proximal tibia. These prior studies appear to be in accordance with our findings. Conclusions We conclude that using the ATA on the resected tibial surface may contribute to an internal rotation error.</description><identifier>ISSN: 0341-2695</identifier><identifier>EISSN: 1432-5195</identifier><identifier>DOI: 10.1007/s00264-015-2858-8</identifier><identifier>PMID: 26156716</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Arthroplasty, Replacement, Knee - adverse effects ; Arthroplasty, Replacement, Knee - methods ; Biomechanical Phenomena ; Bone Malalignment - diagnostic imaging ; Bone Malalignment - etiology ; Bone Malalignment - physiopathology ; Cadaver ; Humans ; Knee Joint - diagnostic imaging ; Knee Joint - physiopathology ; Knee Joint - surgery ; Medicine ; Medicine &amp; Public Health ; Original Paper ; Orthopedics ; Rotation ; Tibia - diagnostic imaging ; Tibia - physiopathology ; Tibia - surgery ; Tomography, X-Ray Computed</subject><ispartof>International orthopaedics, 2015-12, Vol.39 (12), p.2347-2353</ispartof><rights>SICOT aisbl 2015</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c523t-543701006f3aafd60cd4808b51a7a9fbc78e275c307e319e3ed5e5a153d5889c3</citedby><cites>FETCH-LOGICAL-c523t-543701006f3aafd60cd4808b51a7a9fbc78e275c307e319e3ed5e5a153d5889c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00264-015-2858-8$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00264-015-2858-8$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>315,781,785,27929,27930,41493,42562,51324</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26156716$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Forster-Horvath, Csaba</creatorcontrib><creatorcontrib>Kremo, Valerie</creatorcontrib><creatorcontrib>Müller-Gerbl, Magdalena</creatorcontrib><creatorcontrib>Nowakowski, Andrej Maria</creatorcontrib><title>Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error</title><title>International orthopaedics</title><addtitle>International Orthopaedics (SICOT)</addtitle><addtitle>Int Orthop</addtitle><description>Introduction Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. We hypothesise that using the anatomical tibial axis (ATA) to align tibial component rotation on the resected tibial surface may lead to an internal rotation error due to relative anterior shift of the lateral articular surface centre compared to the medial one. The aim of this study was to compare the anatomical tibial axis of the physiological tibial joint surface to the resected one. Method Twenty formalin-fixed cadaveric knees were obtained for study. After computed tomography scanning the data of each specimen were entered into a standardised coordinate system and virtual bone cuts were performed with 6, 8 and 10 mm resection depths. The positions of the articular surface centres were determined at each resection depth. Results The lateral articular surface centre had moved anteriorly after the resection by a mean 1.475 mm, while the medial one had not changed significantly. Resecting the tibia at a 6-mm cut and using the transverse tibial axis to align the prosthetic tibial plateau will result in a mean 4.0° (95 % confidence interval, 2.5-5.5°) of internal rotation compared to the uncut tibia. Discussion The ATA lies in 6 degrees of external rotation compared to the perpendicular to the posterior tibial condylar axis (PTCA). Graw et al. suggest aligning the tibial component in 10 degrees of external rotation to the latter. Thus, if we accept the above suggestion, the ATA is 4 degrees internally rotated compared to the same line on the resected proximal tibia. These prior studies appear to be in accordance with our findings. Conclusions We conclude that using the ATA on the resected tibial surface may contribute to an internal rotation error.</description><subject>Arthroplasty, Replacement, Knee - adverse effects</subject><subject>Arthroplasty, Replacement, Knee - methods</subject><subject>Biomechanical Phenomena</subject><subject>Bone Malalignment - diagnostic imaging</subject><subject>Bone Malalignment - etiology</subject><subject>Bone Malalignment - physiopathology</subject><subject>Cadaver</subject><subject>Humans</subject><subject>Knee Joint - diagnostic imaging</subject><subject>Knee Joint - physiopathology</subject><subject>Knee Joint - surgery</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Original Paper</subject><subject>Orthopedics</subject><subject>Rotation</subject><subject>Tibia - diagnostic imaging</subject><subject>Tibia - physiopathology</subject><subject>Tibia - surgery</subject><subject>Tomography, X-Ray Computed</subject><issn>0341-2695</issn><issn>1432-5195</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMtOwzAQRS0EgvL4ADbISzYBTxw_skSIl1SJDawtN5kUQ2IX25Xo3-OqwJLVaDTnXmkOIefAroAxdZ0Yq2VTMRBVrYWu9B6ZQcPrSkAr9smM8QaqWrbiiByn9M4YKKnhkBzVEoRUIGdkek3OL2l-Q2q9zWFynR1pdgtXhv1yiQ4h0hxyWT88FirmtxhWo015Q-3oln5Cn-lkN3RE2xe0FFHnM0ZfMrEkswueYowhnpKDwY4Jz37mCXm9v3u5fazmzw9PtzfzqhM1z5VouGLlQzlwa4desq5vNNMLAVbZdlh0SmOtRMeZQg4tcuwFCguC90LrtuMn5HLXu4rhc40pm8mlDsfRegzrZEDxkpPQiILCDu1iSCniYFbRTTZuDDCztWx2lk2xbLaWjS6Zi5_69WLC_i_xq7UA9Q5I5eSXGM17WG99pH9avwGo_Ijr</recordid><startdate>20151201</startdate><enddate>20151201</enddate><creator>Forster-Horvath, Csaba</creator><creator>Kremo, Valerie</creator><creator>Müller-Gerbl, Magdalena</creator><creator>Nowakowski, Andrej Maria</creator><general>Springer Berlin Heidelberg</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20151201</creationdate><title>Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error</title><author>Forster-Horvath, Csaba ; Kremo, Valerie ; Müller-Gerbl, Magdalena ; Nowakowski, Andrej Maria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c523t-543701006f3aafd60cd4808b51a7a9fbc78e275c307e319e3ed5e5a153d5889c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Arthroplasty, Replacement, Knee - adverse effects</topic><topic>Arthroplasty, Replacement, Knee - methods</topic><topic>Biomechanical Phenomena</topic><topic>Bone Malalignment - diagnostic imaging</topic><topic>Bone Malalignment - etiology</topic><topic>Bone Malalignment - physiopathology</topic><topic>Cadaver</topic><topic>Humans</topic><topic>Knee Joint - diagnostic imaging</topic><topic>Knee Joint - physiopathology</topic><topic>Knee Joint - surgery</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Original Paper</topic><topic>Orthopedics</topic><topic>Rotation</topic><topic>Tibia - diagnostic imaging</topic><topic>Tibia - physiopathology</topic><topic>Tibia - surgery</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Forster-Horvath, Csaba</creatorcontrib><creatorcontrib>Kremo, Valerie</creatorcontrib><creatorcontrib>Müller-Gerbl, Magdalena</creatorcontrib><creatorcontrib>Nowakowski, Andrej Maria</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Forster-Horvath, Csaba</au><au>Kremo, Valerie</au><au>Müller-Gerbl, Magdalena</au><au>Nowakowski, Andrej Maria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error</atitle><jtitle>International orthopaedics</jtitle><stitle>International Orthopaedics (SICOT)</stitle><addtitle>Int Orthop</addtitle><date>2015-12-01</date><risdate>2015</risdate><volume>39</volume><issue>12</issue><spage>2347</spage><epage>2353</epage><pages>2347-2353</pages><issn>0341-2695</issn><eissn>1432-5195</eissn><abstract>Introduction Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. We hypothesise that using the anatomical tibial axis (ATA) to align tibial component rotation on the resected tibial surface may lead to an internal rotation error due to relative anterior shift of the lateral articular surface centre compared to the medial one. The aim of this study was to compare the anatomical tibial axis of the physiological tibial joint surface to the resected one. Method Twenty formalin-fixed cadaveric knees were obtained for study. After computed tomography scanning the data of each specimen were entered into a standardised coordinate system and virtual bone cuts were performed with 6, 8 and 10 mm resection depths. The positions of the articular surface centres were determined at each resection depth. Results The lateral articular surface centre had moved anteriorly after the resection by a mean 1.475 mm, while the medial one had not changed significantly. Resecting the tibia at a 6-mm cut and using the transverse tibial axis to align the prosthetic tibial plateau will result in a mean 4.0° (95 % confidence interval, 2.5-5.5°) of internal rotation compared to the uncut tibia. Discussion The ATA lies in 6 degrees of external rotation compared to the perpendicular to the posterior tibial condylar axis (PTCA). Graw et al. suggest aligning the tibial component in 10 degrees of external rotation to the latter. Thus, if we accept the above suggestion, the ATA is 4 degrees internally rotated compared to the same line on the resected proximal tibia. These prior studies appear to be in accordance with our findings. Conclusions We conclude that using the ATA on the resected tibial surface may contribute to an internal rotation error.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>26156716</pmid><doi>10.1007/s00264-015-2858-8</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0341-2695
ispartof International orthopaedics, 2015-12, Vol.39 (12), p.2347-2353
issn 0341-2695
1432-5195
language eng
recordid cdi_proquest_miscellaneous_1733196145
source MEDLINE; Springer Online Journals Complete; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Arthroplasty, Replacement, Knee - adverse effects
Arthroplasty, Replacement, Knee - methods
Biomechanical Phenomena
Bone Malalignment - diagnostic imaging
Bone Malalignment - etiology
Bone Malalignment - physiopathology
Cadaver
Humans
Knee Joint - diagnostic imaging
Knee Joint - physiopathology
Knee Joint - surgery
Medicine
Medicine & Public Health
Original Paper
Orthopedics
Rotation
Tibia - diagnostic imaging
Tibia - physiopathology
Tibia - surgery
Tomography, X-Ray Computed
title Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T08%3A13%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Using%20the%20anatomical%20tibial%20axis%20for%20total%20knee%20arthroplasty%20alignment%20may%20lead%20to%20an%20internal%20rotation%20error&rft.jtitle=International%20orthopaedics&rft.au=Forster-Horvath,%20Csaba&rft.date=2015-12-01&rft.volume=39&rft.issue=12&rft.spage=2347&rft.epage=2353&rft.pages=2347-2353&rft.issn=0341-2695&rft.eissn=1432-5195&rft_id=info:doi/10.1007/s00264-015-2858-8&rft_dat=%3Cproquest_cross%3E1733196145%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1733196145&rft_id=info:pmid/26156716&rfr_iscdi=true