High resolution 3D dosimetry for microbeam radiation therapy using optical CT
Optical Computed Tomography (CT) is a promising technique for dosimetry of Microbeam Radiation Therapy (MRT), providing high resolution 3D dose maps. Here different MRT irradiation geometries are visualised showing the potential of Optical CT as a tool for future MRT trials. The Peak-to-Valley dose...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2015-01, Vol.573 (1), p.12032-4 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | 1 |
container_start_page | 12032 |
container_title | Journal of physics. Conference series |
container_volume | 573 |
creator | McErlean, C Bräuer-Krisch, E Adamovics, J Leach, M O Doran, S J |
description | Optical Computed Tomography (CT) is a promising technique for dosimetry of Microbeam Radiation Therapy (MRT), providing high resolution 3D dose maps. Here different MRT irradiation geometries are visualised showing the potential of Optical CT as a tool for future MRT trials. The Peak-to-Valley dose ratio (PVDR) is calculated to be 7 at a depth of 3mm in the radiochromic dosimeter PRESAGE®. This is significantly lower than predicted values and possible reasons for this are discussed. |
doi_str_mv | 10.1088/1742-6596/573/1/012032 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_proquest_miscellaneous_1730091051</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1730091051</sourcerecordid><originalsourceid>FETCH-LOGICAL-c398t-2f51b77185bd4d19546ab2ca47aeecff0cde8c1a30596dd09a2dc40e48a662423</originalsourceid><addsrcrecordid>eNpdkU1PwzAMhiMEEmPwF1AkLnAoi5O2SY_T-BjSEJdxjtI03TK1TUlapP17Wop2wBdb9iPLfl-EboE8AhFiATymUZpk6SLhbAELApQweoZmp8H5qRbiEl2FcCCEDcFn6H1td3vsTXBV31nXYPaECxdsbTp_xKXzuLbau9yoGntVWPULdXvjVXvEfbDNDru2s1pVeLW9RhelqoK5-ctz9PnyvF2to83H69tquYk0y0QX0TKBnHMQSV7EBWRJnKqcahVzZYwuS6ILIzQoRobji4JkihY6JiYWKk1pTNkcPUx796qSrbe18kfplJXr5UaOPQIJp4Kn3zCw9xPbevfVm9DJ2gZtqko1xvVBAmeEZECSEb37hx5c75vhE0kTngIjkImBSidq0CUEb8rTBUDk6IgcxZaj8HJwRIKcHGE_piR9Hw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2576130198</pqid></control><display><type>article</type><title>High resolution 3D dosimetry for microbeam radiation therapy using optical CT</title><source>IOP Publishing Free Content</source><source>EZB-FREE-00999 freely available EZB journals</source><source>IOPscience extra</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>McErlean, C ; Bräuer-Krisch, E ; Adamovics, J ; Leach, M O ; Doran, S J</creator><creatorcontrib>McErlean, C ; Bräuer-Krisch, E ; Adamovics, J ; Leach, M O ; Doran, S J</creatorcontrib><description>Optical Computed Tomography (CT) is a promising technique for dosimetry of Microbeam Radiation Therapy (MRT), providing high resolution 3D dose maps. Here different MRT irradiation geometries are visualised showing the potential of Optical CT as a tool for future MRT trials. The Peak-to-Valley dose ratio (PVDR) is calculated to be 7 at a depth of 3mm in the radiochromic dosimeter PRESAGE®. This is significantly lower than predicted values and possible reasons for this are discussed.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/573/1/012032</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Computed tomography ; Dosimeters ; Dosimetry ; High resolution ; Life Sciences ; Mathematical analysis ; Microbeams ; Physics ; Radiation therapy ; Three dimensional</subject><ispartof>Journal of physics. Conference series, 2015-01, Vol.573 (1), p.12032-4</ispartof><rights>2015. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c398t-2f51b77185bd4d19546ab2ca47aeecff0cde8c1a30596dd09a2dc40e48a662423</citedby><cites>FETCH-LOGICAL-c398t-2f51b77185bd4d19546ab2ca47aeecff0cde8c1a30596dd09a2dc40e48a662423</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,309,314,780,784,885,27922,27923</link.rule.ids><backlink>$$Uhttps://hal.science/hal-01572876$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>McErlean, C</creatorcontrib><creatorcontrib>Bräuer-Krisch, E</creatorcontrib><creatorcontrib>Adamovics, J</creatorcontrib><creatorcontrib>Leach, M O</creatorcontrib><creatorcontrib>Doran, S J</creatorcontrib><title>High resolution 3D dosimetry for microbeam radiation therapy using optical CT</title><title>Journal of physics. Conference series</title><description>Optical Computed Tomography (CT) is a promising technique for dosimetry of Microbeam Radiation Therapy (MRT), providing high resolution 3D dose maps. Here different MRT irradiation geometries are visualised showing the potential of Optical CT as a tool for future MRT trials. The Peak-to-Valley dose ratio (PVDR) is calculated to be 7 at a depth of 3mm in the radiochromic dosimeter PRESAGE®. This is significantly lower than predicted values and possible reasons for this are discussed.</description><subject>Computed tomography</subject><subject>Dosimeters</subject><subject>Dosimetry</subject><subject>High resolution</subject><subject>Life Sciences</subject><subject>Mathematical analysis</subject><subject>Microbeams</subject><subject>Physics</subject><subject>Radiation therapy</subject><subject>Three dimensional</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkU1PwzAMhiMEEmPwF1AkLnAoi5O2SY_T-BjSEJdxjtI03TK1TUlapP17Wop2wBdb9iPLfl-EboE8AhFiATymUZpk6SLhbAELApQweoZmp8H5qRbiEl2FcCCEDcFn6H1td3vsTXBV31nXYPaECxdsbTp_xKXzuLbau9yoGntVWPULdXvjVXvEfbDNDru2s1pVeLW9RhelqoK5-ctz9PnyvF2to83H69tquYk0y0QX0TKBnHMQSV7EBWRJnKqcahVzZYwuS6ILIzQoRobji4JkihY6JiYWKk1pTNkcPUx796qSrbe18kfplJXr5UaOPQIJp4Kn3zCw9xPbevfVm9DJ2gZtqko1xvVBAmeEZECSEb37hx5c75vhE0kTngIjkImBSidq0CUEb8rTBUDk6IgcxZaj8HJwRIKcHGE_piR9Hw</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>McErlean, C</creator><creator>Bräuer-Krisch, E</creator><creator>Adamovics, J</creator><creator>Leach, M O</creator><creator>Doran, S J</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>FR3</scope><scope>JG9</scope><scope>1XC</scope><scope>VOOES</scope></search><sort><creationdate>20150101</creationdate><title>High resolution 3D dosimetry for microbeam radiation therapy using optical CT</title><author>McErlean, C ; Bräuer-Krisch, E ; Adamovics, J ; Leach, M O ; Doran, S J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c398t-2f51b77185bd4d19546ab2ca47aeecff0cde8c1a30596dd09a2dc40e48a662423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Computed tomography</topic><topic>Dosimeters</topic><topic>Dosimetry</topic><topic>High resolution</topic><topic>Life Sciences</topic><topic>Mathematical analysis</topic><topic>Microbeams</topic><topic>Physics</topic><topic>Radiation therapy</topic><topic>Three dimensional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>McErlean, C</creatorcontrib><creatorcontrib>Bräuer-Krisch, E</creatorcontrib><creatorcontrib>Adamovics, J</creatorcontrib><creatorcontrib>Leach, M O</creatorcontrib><creatorcontrib>Doran, S J</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>McErlean, C</au><au>Bräuer-Krisch, E</au><au>Adamovics, J</au><au>Leach, M O</au><au>Doran, S J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High resolution 3D dosimetry for microbeam radiation therapy using optical CT</atitle><jtitle>Journal of physics. Conference series</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>573</volume><issue>1</issue><spage>12032</spage><epage>4</epage><pages>12032-4</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>Optical Computed Tomography (CT) is a promising technique for dosimetry of Microbeam Radiation Therapy (MRT), providing high resolution 3D dose maps. Here different MRT irradiation geometries are visualised showing the potential of Optical CT as a tool for future MRT trials. The Peak-to-Valley dose ratio (PVDR) is calculated to be 7 at a depth of 3mm in the radiochromic dosimeter PRESAGE®. This is significantly lower than predicted values and possible reasons for this are discussed.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/573/1/012032</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2015-01, Vol.573 (1), p.12032-4 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_miscellaneous_1730091051 |
source | IOP Publishing Free Content; EZB-FREE-00999 freely available EZB journals; IOPscience extra; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | Computed tomography Dosimeters Dosimetry High resolution Life Sciences Mathematical analysis Microbeams Physics Radiation therapy Three dimensional |
title | High resolution 3D dosimetry for microbeam radiation therapy using optical CT |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T00%3A43%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20resolution%203D%20dosimetry%20for%20microbeam%20radiation%20therapy%20using%20optical%20CT&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=McErlean,%20C&rft.date=2015-01-01&rft.volume=573&rft.issue=1&rft.spage=12032&rft.epage=4&rft.pages=12032-4&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/573/1/012032&rft_dat=%3Cproquest_hal_p%3E1730091051%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2576130198&rft_id=info:pmid/&rfr_iscdi=true |