Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams

Slips of mechanical connectors in steel plate reinforced concrete (RC) structures can significantly affect the load-carrying capacity of the structures. The difference in deformation between the steel plate and the reinforced concrete counterpart is known as partial interaction. In this study, the f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of constructional steel research 2010-05, Vol.66 (5), p.622-633
Hauptverfasser: Siu, W.H., Su, R.K.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 633
container_issue 5
container_start_page 622
container_title Journal of constructional steel research
container_volume 66
creator Siu, W.H.
Su, R.K.L.
description Slips of mechanical connectors in steel plate reinforced concrete (RC) structures can significantly affect the load-carrying capacity of the structures. The difference in deformation between the steel plate and the reinforced concrete counterpart is known as partial interaction. In this study, the flexural behaviour of bolted side-plated (BSP) reinforced concrete beams was investigated experimentally. Two new deformation-based parameters, namely the strain factor and curvature factor, were introduced to quantify the degree of partial interaction between the RC beam and the steel plates. The experimental results revealed that the degree of partial interaction between RC beams and steel plates could be reduced by as much as 50% when the BSP beam proceeded from a linear to a non-linear stage in which plastic hinges have formed in critical sections. Consequently, the load-carrying capacity was reduced by up to 30% of the theoretical additional strength provided by the bolt–plate system, which is more than double the allowance proposed previously in the literature. The under-estimation of the effect of partial interaction in composite structures can result in unsafe design.
doi_str_mv 10.1016/j.jcsr.2010.01.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1730059651</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0143974X10000155</els_id><sourcerecordid>1730059651</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-aab34f69dabb782bcbe319814def6227d1129e3ec29433438668318d5faa94923</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMouK7-AU89emnNJNk0AS-yrB-w4EXFW0jTqZul29aku-C_N2U962mGl_cZmIeQa6AFUJC322LrYigYTQGFglJ2QmagSp4vtOKnZEZB8FyX4uOcXMS4pZQqzdWMvK-aBt0Ys77JhtbG0bts47tPTEmXDTaM3raZ70YM1o0-ZRVu7MH3-zAhVd-OWGfR15gnfNortLt4Sc4a20a8-p1z8vawel0-5euXx-fl_Tp3AuiYW1tx0Uhd26oqFatchRy0AlFjIxkrawCmkaNjWnAuuJJScVD1orFWC834nNwc7w6h_9pjHM3OR4dtazvs99FAySldaLmA_6tMylKAFCJV2bHqQh9jwMYMwe9s-DZAzeTbbM3k20y-DQWTfCfo7ghh-vfgMZjoPHYOax-SYVP3_i_8B_aTiRs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1266741644</pqid></control><display><type>article</type><title>Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams</title><source>Elsevier ScienceDirect Journals</source><creator>Siu, W.H. ; Su, R.K.L.</creator><creatorcontrib>Siu, W.H. ; Su, R.K.L.</creatorcontrib><description>Slips of mechanical connectors in steel plate reinforced concrete (RC) structures can significantly affect the load-carrying capacity of the structures. The difference in deformation between the steel plate and the reinforced concrete counterpart is known as partial interaction. In this study, the flexural behaviour of bolted side-plated (BSP) reinforced concrete beams was investigated experimentally. Two new deformation-based parameters, namely the strain factor and curvature factor, were introduced to quantify the degree of partial interaction between the RC beam and the steel plates. The experimental results revealed that the degree of partial interaction between RC beams and steel plates could be reduced by as much as 50% when the BSP beam proceeded from a linear to a non-linear stage in which plastic hinges have formed in critical sections. Consequently, the load-carrying capacity was reduced by up to 30% of the theoretical additional strength provided by the bolt–plate system, which is more than double the allowance proposed previously in the literature. The under-estimation of the effect of partial interaction in composite structures can result in unsafe design.</description><identifier>ISSN: 0143-974X</identifier><identifier>EISSN: 1873-5983</identifier><identifier>DOI: 10.1016/j.jcsr.2010.01.002</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Beams (structural) ; Bolting ; Bolts ; Curvature ; Hinges ; Non-linear ; Plate ; Plates (structural members) ; Reinforced concrete ; Reinforced concrete beams ; Reinforcing steels ; Slip strain ; Structural steels</subject><ispartof>Journal of constructional steel research, 2010-05, Vol.66 (5), p.622-633</ispartof><rights>2010 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-aab34f69dabb782bcbe319814def6227d1129e3ec29433438668318d5faa94923</citedby><cites>FETCH-LOGICAL-c410t-aab34f69dabb782bcbe319814def6227d1129e3ec29433438668318d5faa94923</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0143974X10000155$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Siu, W.H.</creatorcontrib><creatorcontrib>Su, R.K.L.</creatorcontrib><title>Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams</title><title>Journal of constructional steel research</title><description>Slips of mechanical connectors in steel plate reinforced concrete (RC) structures can significantly affect the load-carrying capacity of the structures. The difference in deformation between the steel plate and the reinforced concrete counterpart is known as partial interaction. In this study, the flexural behaviour of bolted side-plated (BSP) reinforced concrete beams was investigated experimentally. Two new deformation-based parameters, namely the strain factor and curvature factor, were introduced to quantify the degree of partial interaction between the RC beam and the steel plates. The experimental results revealed that the degree of partial interaction between RC beams and steel plates could be reduced by as much as 50% when the BSP beam proceeded from a linear to a non-linear stage in which plastic hinges have formed in critical sections. Consequently, the load-carrying capacity was reduced by up to 30% of the theoretical additional strength provided by the bolt–plate system, which is more than double the allowance proposed previously in the literature. The under-estimation of the effect of partial interaction in composite structures can result in unsafe design.</description><subject>Beams (structural)</subject><subject>Bolting</subject><subject>Bolts</subject><subject>Curvature</subject><subject>Hinges</subject><subject>Non-linear</subject><subject>Plate</subject><subject>Plates (structural members)</subject><subject>Reinforced concrete</subject><subject>Reinforced concrete beams</subject><subject>Reinforcing steels</subject><subject>Slip strain</subject><subject>Structural steels</subject><issn>0143-974X</issn><issn>1873-5983</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LxDAQhoMouK7-AU89emnNJNk0AS-yrB-w4EXFW0jTqZul29aku-C_N2U962mGl_cZmIeQa6AFUJC322LrYigYTQGFglJ2QmagSp4vtOKnZEZB8FyX4uOcXMS4pZQqzdWMvK-aBt0Ys77JhtbG0bts47tPTEmXDTaM3raZ70YM1o0-ZRVu7MH3-zAhVd-OWGfR15gnfNortLt4Sc4a20a8-p1z8vawel0-5euXx-fl_Tp3AuiYW1tx0Uhd26oqFatchRy0AlFjIxkrawCmkaNjWnAuuJJScVD1orFWC834nNwc7w6h_9pjHM3OR4dtazvs99FAySldaLmA_6tMylKAFCJV2bHqQh9jwMYMwe9s-DZAzeTbbM3k20y-DQWTfCfo7ghh-vfgMZjoPHYOax-SYVP3_i_8B_aTiRs</recordid><startdate>20100501</startdate><enddate>20100501</enddate><creator>Siu, W.H.</creator><creator>Su, R.K.L.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>KR7</scope></search><sort><creationdate>20100501</creationdate><title>Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams</title><author>Siu, W.H. ; Su, R.K.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-aab34f69dabb782bcbe319814def6227d1129e3ec29433438668318d5faa94923</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Beams (structural)</topic><topic>Bolting</topic><topic>Bolts</topic><topic>Curvature</topic><topic>Hinges</topic><topic>Non-linear</topic><topic>Plate</topic><topic>Plates (structural members)</topic><topic>Reinforced concrete</topic><topic>Reinforced concrete beams</topic><topic>Reinforcing steels</topic><topic>Slip strain</topic><topic>Structural steels</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Siu, W.H.</creatorcontrib><creatorcontrib>Su, R.K.L.</creatorcontrib><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of constructional steel research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Siu, W.H.</au><au>Su, R.K.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams</atitle><jtitle>Journal of constructional steel research</jtitle><date>2010-05-01</date><risdate>2010</risdate><volume>66</volume><issue>5</issue><spage>622</spage><epage>633</epage><pages>622-633</pages><issn>0143-974X</issn><eissn>1873-5983</eissn><abstract>Slips of mechanical connectors in steel plate reinforced concrete (RC) structures can significantly affect the load-carrying capacity of the structures. The difference in deformation between the steel plate and the reinforced concrete counterpart is known as partial interaction. In this study, the flexural behaviour of bolted side-plated (BSP) reinforced concrete beams was investigated experimentally. Two new deformation-based parameters, namely the strain factor and curvature factor, were introduced to quantify the degree of partial interaction between the RC beam and the steel plates. The experimental results revealed that the degree of partial interaction between RC beams and steel plates could be reduced by as much as 50% when the BSP beam proceeded from a linear to a non-linear stage in which plastic hinges have formed in critical sections. Consequently, the load-carrying capacity was reduced by up to 30% of the theoretical additional strength provided by the bolt–plate system, which is more than double the allowance proposed previously in the literature. The under-estimation of the effect of partial interaction in composite structures can result in unsafe design.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.jcsr.2010.01.002</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0143-974X
ispartof Journal of constructional steel research, 2010-05, Vol.66 (5), p.622-633
issn 0143-974X
1873-5983
language eng
recordid cdi_proquest_miscellaneous_1730059651
source Elsevier ScienceDirect Journals
subjects Beams (structural)
Bolting
Bolts
Curvature
Hinges
Non-linear
Plate
Plates (structural members)
Reinforced concrete
Reinforced concrete beams
Reinforcing steels
Slip strain
Structural steels
title Effects of plastic hinges on partial interaction behaviour of bolted side-plated beams
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T10%3A50%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20plastic%20hinges%20on%20partial%20interaction%20behaviour%20of%20bolted%20side-plated%20beams&rft.jtitle=Journal%20of%20constructional%20steel%20research&rft.au=Siu,%20W.H.&rft.date=2010-05-01&rft.volume=66&rft.issue=5&rft.spage=622&rft.epage=633&rft.pages=622-633&rft.issn=0143-974X&rft.eissn=1873-5983&rft_id=info:doi/10.1016/j.jcsr.2010.01.002&rft_dat=%3Cproquest_cross%3E1730059651%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1266741644&rft_id=info:pmid/&rft_els_id=S0143974X10000155&rfr_iscdi=true