Off-resonance suppression for multispectral MR imaging near metallic implants

Purpose Metal artifact reduction in MRI within clinically feasible scan‐times without through‐plane aliasing. Theory and Methods Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in‐plane distortions, and multispectral imaging (MSI) techniques, such as sli...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 2015-01, Vol.73 (1), p.233-243
Hauptverfasser: den Harder, J. Chiel, van Yperen, Gert H., Blume, Ulrike A., Bos, Clemens
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 243
container_issue 1
container_start_page 233
container_title Magnetic resonance in medicine
container_volume 73
creator den Harder, J. Chiel
van Yperen, Gert H.
Blume, Ulrike A.
Bos, Clemens
description Purpose Metal artifact reduction in MRI within clinically feasible scan‐times without through‐plane aliasing. Theory and Methods Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in‐plane distortions, and multispectral imaging (MSI) techniques, such as slice encoding for metal artifact correction (SEMAC) and multi‐acquisition with variable resonances image combination (MAVRIC), that further reduce image distortions, but significantly increase scan‐time. Scan‐time depends on anatomy size and anticipated total spectral content of the signal. Signals outside the anticipated spatial region may cause through‐plane back‐folding. Off‐resonance suppression (ORS), using different gradient amplitudes for excitation and refocusing, is proposed to provide well‐defined spatial‐spectral selectivity in MSI to allow scan‐time reduction and flexibility of scan‐orientation. Comparisons of MSI techniques with and without ORS were made in phantom and volunteer experiments. Results Off‐resonance suppressed SEMAC (ORS‐SEMAC) and outer‐region suppressed MAVRIC (ORS‐MAVRIC) required limited through‐plane phase encoding steps compared with original MSI. Whereas SEMAC (scan time: 5′46″) and MAVRIC (4′12″) suffered from through‐plane aliasing, ORS‐SEMAC and ORS‐MAVRIC allowed alias‐free imaging in the same scan‐times. Conclusion ORS can be used in MSI to limit the selected spatial‐spectral region and contribute to metal artifact reduction in clinically feasible scan‐times while avoiding slice aliasing. Magn Reson Med 73:233–243, 2015. © 2014 Wiley Periodicals, Inc.
doi_str_mv 10.1002/mrm.25126
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1728674067</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1728674067</sourcerecordid><originalsourceid>FETCH-LOGICAL-c5296-3f08094b78806612d866e604a2753fed301e1a253332e090d4a820784459d8943</originalsourceid><addsrcrecordid>eNqFkUtP3DAUha2qVRkei_6BKlI3sAhcv-1lhQpTaYaXBrG0THKDQvOqnQj49xgGZlGpYmXZ_u7RPecQ8o3CIQVgR21oD5mkTH0iMyoZy5m04jOZgRaQc2rFFtmO8R4ArNXiK9liQhijjJiR5XlV5QFj3_muwCxOw5Buse67rOpD1k7NWMcBizH4JlteZXXr7-ruLuvQp18cfdPURXodGt-NcZd8qXwTce_t3CHXJ79Wx_N8cX76-_jnIi8ksyrnFRiw4lYbA0pRVhqlUIHwTEteYcmBIvVMcs4ZgoVSeMNAGyGkLY0VfIfsr3WH0P-dMI6urWOBTVoC-yk6qplRybzSH6NKaEi8Zgn98Q9630-hS0ZeqJSeMkATdbCmitDHGLByQ0iphCdHwb3U4VId7rWOxH5_U5xuWyw35Hv-CThaAw91g0__V3LLq-W7ZL6eqOOIj5sJH_645FZLd3N26ubqYiXncuUu-TNDDaA5</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1640006801</pqid></control><display><type>article</type><title>Off-resonance suppression for multispectral MR imaging near metallic implants</title><source>MEDLINE</source><source>Wiley Journals</source><source>Wiley Online Library (Open Access Collection)</source><creator>den Harder, J. Chiel ; van Yperen, Gert H. ; Blume, Ulrike A. ; Bos, Clemens</creator><creatorcontrib>den Harder, J. Chiel ; van Yperen, Gert H. ; Blume, Ulrike A. ; Bos, Clemens</creatorcontrib><description>Purpose Metal artifact reduction in MRI within clinically feasible scan‐times without through‐plane aliasing. Theory and Methods Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in‐plane distortions, and multispectral imaging (MSI) techniques, such as slice encoding for metal artifact correction (SEMAC) and multi‐acquisition with variable resonances image combination (MAVRIC), that further reduce image distortions, but significantly increase scan‐time. Scan‐time depends on anatomy size and anticipated total spectral content of the signal. Signals outside the anticipated spatial region may cause through‐plane back‐folding. Off‐resonance suppression (ORS), using different gradient amplitudes for excitation and refocusing, is proposed to provide well‐defined spatial‐spectral selectivity in MSI to allow scan‐time reduction and flexibility of scan‐orientation. Comparisons of MSI techniques with and without ORS were made in phantom and volunteer experiments. Results Off‐resonance suppressed SEMAC (ORS‐SEMAC) and outer‐region suppressed MAVRIC (ORS‐MAVRIC) required limited through‐plane phase encoding steps compared with original MSI. Whereas SEMAC (scan time: 5′46″) and MAVRIC (4′12″) suffered from through‐plane aliasing, ORS‐SEMAC and ORS‐MAVRIC allowed alias‐free imaging in the same scan‐times. Conclusion ORS can be used in MSI to limit the selected spatial‐spectral region and contribute to metal artifact reduction in clinically feasible scan‐times while avoiding slice aliasing. Magn Reson Med 73:233–243, 2015. © 2014 Wiley Periodicals, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.25126</identifier><identifier>PMID: 24488684</identifier><identifier>CODEN: MRMEEN</identifier><language>eng</language><publisher>United States: Blackwell Publishing Ltd</publisher><subject>Algorithms ; arthroplasty ; Hip Joint - pathology ; Hip Joint - surgery ; Hip Prosthesis ; Humans ; Image Enhancement - methods ; Image Interpretation, Computer-Assisted - methods ; magnetic resonance imaging ; Magnetic Resonance Imaging - methods ; MAVRIC ; metal implants ; Metals ; multispectral imaging ; Reproducibility of Results ; SEMAC ; Sensitivity and Specificity</subject><ispartof>Magnetic resonance in medicine, 2015-01, Vol.73 (1), p.233-243</ispartof><rights>2014 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c5296-3f08094b78806612d866e604a2753fed301e1a253332e090d4a820784459d8943</citedby><cites>FETCH-LOGICAL-c5296-3f08094b78806612d866e604a2753fed301e1a253332e090d4a820784459d8943</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.25126$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.25126$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,1433,27924,27925,45574,45575,46409,46833</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24488684$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>den Harder, J. Chiel</creatorcontrib><creatorcontrib>van Yperen, Gert H.</creatorcontrib><creatorcontrib>Blume, Ulrike A.</creatorcontrib><creatorcontrib>Bos, Clemens</creatorcontrib><title>Off-resonance suppression for multispectral MR imaging near metallic implants</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>Purpose Metal artifact reduction in MRI within clinically feasible scan‐times without through‐plane aliasing. Theory and Methods Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in‐plane distortions, and multispectral imaging (MSI) techniques, such as slice encoding for metal artifact correction (SEMAC) and multi‐acquisition with variable resonances image combination (MAVRIC), that further reduce image distortions, but significantly increase scan‐time. Scan‐time depends on anatomy size and anticipated total spectral content of the signal. Signals outside the anticipated spatial region may cause through‐plane back‐folding. Off‐resonance suppression (ORS), using different gradient amplitudes for excitation and refocusing, is proposed to provide well‐defined spatial‐spectral selectivity in MSI to allow scan‐time reduction and flexibility of scan‐orientation. Comparisons of MSI techniques with and without ORS were made in phantom and volunteer experiments. Results Off‐resonance suppressed SEMAC (ORS‐SEMAC) and outer‐region suppressed MAVRIC (ORS‐MAVRIC) required limited through‐plane phase encoding steps compared with original MSI. Whereas SEMAC (scan time: 5′46″) and MAVRIC (4′12″) suffered from through‐plane aliasing, ORS‐SEMAC and ORS‐MAVRIC allowed alias‐free imaging in the same scan‐times. Conclusion ORS can be used in MSI to limit the selected spatial‐spectral region and contribute to metal artifact reduction in clinically feasible scan‐times while avoiding slice aliasing. Magn Reson Med 73:233–243, 2015. © 2014 Wiley Periodicals, Inc.</description><subject>Algorithms</subject><subject>arthroplasty</subject><subject>Hip Joint - pathology</subject><subject>Hip Joint - surgery</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>magnetic resonance imaging</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>MAVRIC</subject><subject>metal implants</subject><subject>Metals</subject><subject>multispectral imaging</subject><subject>Reproducibility of Results</subject><subject>SEMAC</subject><subject>Sensitivity and Specificity</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkUtP3DAUha2qVRkei_6BKlI3sAhcv-1lhQpTaYaXBrG0THKDQvOqnQj49xgGZlGpYmXZ_u7RPecQ8o3CIQVgR21oD5mkTH0iMyoZy5m04jOZgRaQc2rFFtmO8R4ArNXiK9liQhijjJiR5XlV5QFj3_muwCxOw5Buse67rOpD1k7NWMcBizH4JlteZXXr7-ruLuvQp18cfdPURXodGt-NcZd8qXwTce_t3CHXJ79Wx_N8cX76-_jnIi8ksyrnFRiw4lYbA0pRVhqlUIHwTEteYcmBIvVMcs4ZgoVSeMNAGyGkLY0VfIfsr3WH0P-dMI6urWOBTVoC-yk6qplRybzSH6NKaEi8Zgn98Q9630-hS0ZeqJSeMkATdbCmitDHGLByQ0iphCdHwb3U4VId7rWOxH5_U5xuWyw35Hv-CThaAw91g0__V3LLq-W7ZL6eqOOIj5sJH_645FZLd3N26ubqYiXncuUu-TNDDaA5</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>den Harder, J. Chiel</creator><creator>van Yperen, Gert H.</creator><creator>Blume, Ulrike A.</creator><creator>Bos, Clemens</creator><general>Blackwell Publishing Ltd</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><scope>7QO</scope><scope>7X8</scope></search><sort><creationdate>201501</creationdate><title>Off-resonance suppression for multispectral MR imaging near metallic implants</title><author>den Harder, J. Chiel ; van Yperen, Gert H. ; Blume, Ulrike A. ; Bos, Clemens</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c5296-3f08094b78806612d866e604a2753fed301e1a253332e090d4a820784459d8943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Algorithms</topic><topic>arthroplasty</topic><topic>Hip Joint - pathology</topic><topic>Hip Joint - surgery</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>magnetic resonance imaging</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>MAVRIC</topic><topic>metal implants</topic><topic>Metals</topic><topic>multispectral imaging</topic><topic>Reproducibility of Results</topic><topic>SEMAC</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>den Harder, J. Chiel</creatorcontrib><creatorcontrib>van Yperen, Gert H.</creatorcontrib><creatorcontrib>Blume, Ulrike A.</creatorcontrib><creatorcontrib>Bos, Clemens</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>den Harder, J. Chiel</au><au>van Yperen, Gert H.</au><au>Blume, Ulrike A.</au><au>Bos, Clemens</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Off-resonance suppression for multispectral MR imaging near metallic implants</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2015-01</date><risdate>2015</risdate><volume>73</volume><issue>1</issue><spage>233</spage><epage>243</epage><pages>233-243</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><coden>MRMEEN</coden><abstract>Purpose Metal artifact reduction in MRI within clinically feasible scan‐times without through‐plane aliasing. Theory and Methods Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in‐plane distortions, and multispectral imaging (MSI) techniques, such as slice encoding for metal artifact correction (SEMAC) and multi‐acquisition with variable resonances image combination (MAVRIC), that further reduce image distortions, but significantly increase scan‐time. Scan‐time depends on anatomy size and anticipated total spectral content of the signal. Signals outside the anticipated spatial region may cause through‐plane back‐folding. Off‐resonance suppression (ORS), using different gradient amplitudes for excitation and refocusing, is proposed to provide well‐defined spatial‐spectral selectivity in MSI to allow scan‐time reduction and flexibility of scan‐orientation. Comparisons of MSI techniques with and without ORS were made in phantom and volunteer experiments. Results Off‐resonance suppressed SEMAC (ORS‐SEMAC) and outer‐region suppressed MAVRIC (ORS‐MAVRIC) required limited through‐plane phase encoding steps compared with original MSI. Whereas SEMAC (scan time: 5′46″) and MAVRIC (4′12″) suffered from through‐plane aliasing, ORS‐SEMAC and ORS‐MAVRIC allowed alias‐free imaging in the same scan‐times. Conclusion ORS can be used in MSI to limit the selected spatial‐spectral region and contribute to metal artifact reduction in clinically feasible scan‐times while avoiding slice aliasing. Magn Reson Med 73:233–243, 2015. © 2014 Wiley Periodicals, Inc.</abstract><cop>United States</cop><pub>Blackwell Publishing Ltd</pub><pmid>24488684</pmid><doi>10.1002/mrm.25126</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2015-01, Vol.73 (1), p.233-243
issn 0740-3194
1522-2594
language eng
recordid cdi_proquest_miscellaneous_1728674067
source MEDLINE; Wiley Journals; Wiley Online Library (Open Access Collection)
subjects Algorithms
arthroplasty
Hip Joint - pathology
Hip Joint - surgery
Hip Prosthesis
Humans
Image Enhancement - methods
Image Interpretation, Computer-Assisted - methods
magnetic resonance imaging
Magnetic Resonance Imaging - methods
MAVRIC
metal implants
Metals
multispectral imaging
Reproducibility of Results
SEMAC
Sensitivity and Specificity
title Off-resonance suppression for multispectral MR imaging near metallic implants
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T12%3A43%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Off-resonance%20suppression%20for%20multispectral%20MR%20imaging%20near%20metallic%20implants&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=den%20Harder,%20J.%20Chiel&rft.date=2015-01&rft.volume=73&rft.issue=1&rft.spage=233&rft.epage=243&rft.pages=233-243&rft.issn=0740-3194&rft.eissn=1522-2594&rft.coden=MRMEEN&rft_id=info:doi/10.1002/mrm.25126&rft_dat=%3Cproquest_cross%3E1728674067%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1640006801&rft_id=info:pmid/24488684&rfr_iscdi=true