Model predictive control of a reverse osmosis desalination unit
Model predictive control (MPC) has established itself as the leading form of advanced control in the process industry. One of the most popular MPC strategies is the dynamic matrix control (DMC) algorithm. In this paper, the DMC algorithm with/without constraints is used for the control of a simulate...
Gespeichert in:
Veröffentlicht in: | Desalination 2006-06, Vol.194 (1), p.268-280 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 280 |
---|---|
container_issue | 1 |
container_start_page | 268 |
container_title | Desalination |
container_volume | 194 |
creator | Abbas, Abderrahim |
description | Model predictive control (MPC) has established itself as the leading form of advanced control in the process industry. One of the most popular MPC strategies is the dynamic matrix control (DMC) algorithm. In this paper, the DMC algorithm with/without constraints is used for the control of a simulated reverse osmosis water desalination unit based on a hollow-fiber membrane. The controller was tuned using a recently presented simple method. Two cases were considered. In the first, the permeate flux was controlled by manipulating feed pressure. The second was a multivariable case in which both the permeate flow rate and conductivity (a measure of quality) are controlled by adjusting the feed pressure and pH. The performances of the DMC were analyzed and compared to those obtained from a control system based on classical PI controllers. The sensitivity of the DMC to changes in a key plant parameter, namely the gain-relating changes in the permeate flow rate to changes in the feed pressure, was also investigated. The results show that the DMC offers a substantially better performance than classical PI controllers. Also, it has good robustness characteristics. It continued to produce good control for even large changes, ±30%, in the gain relating the product flow rate to feed pressure. |
doi_str_mv | 10.1016/j.desal.2005.10.033 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17194878</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0011916406003808</els_id><sourcerecordid>17194878</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-4ede5d8abfd0b5279f4ea403b47e06bf95d20a60e88afac6ac4e37aa5385fea33</originalsourceid><addsrcrecordid>eNp9UMtKAzEUDaJgrX6Bm2x0NzWZZCaZhYgUX1Bxo-twJ7mBlOmkJtOCf-_0Ae5cXe7hPDiHkGvOZpzx-m45c5ihm5WMVSMyY0KckAnXShRS1vKUTBjjvGh4Lc_JRc7L8S0bISbk4T067Og6oQt2CFukNvZDih2NngJNuMWUkca8ijlkuo8JPQwh9nTTh-GSnHnoMl4d75R8PT99zl-LxcfL2_xxUVhRy6GQ6LByGlrvWFuVqvESQTLRSoWsbn1TuZJBzVBr8GBrsBKFAqiErjyCEFNye_Bdp_i9wTyYVcgWuw56jJtsuOKN1EqPRHEg2hRzTujNOoUVpB_DmdmNZZZm38LsxtqB41ij6uZoD9lC5xP0NuQ_qdJSad6MvPsDD8eu24DJZBuwt-N6Ce1gXAz_5vwCkTuB8Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17194878</pqid></control><display><type>article</type><title>Model predictive control of a reverse osmosis desalination unit</title><source>Elsevier ScienceDirect Journals</source><creator>Abbas, Abderrahim</creator><creatorcontrib>Abbas, Abderrahim</creatorcontrib><description>Model predictive control (MPC) has established itself as the leading form of advanced control in the process industry. One of the most popular MPC strategies is the dynamic matrix control (DMC) algorithm. In this paper, the DMC algorithm with/without constraints is used for the control of a simulated reverse osmosis water desalination unit based on a hollow-fiber membrane. The controller was tuned using a recently presented simple method. Two cases were considered. In the first, the permeate flux was controlled by manipulating feed pressure. The second was a multivariable case in which both the permeate flow rate and conductivity (a measure of quality) are controlled by adjusting the feed pressure and pH. The performances of the DMC were analyzed and compared to those obtained from a control system based on classical PI controllers. The sensitivity of the DMC to changes in a key plant parameter, namely the gain-relating changes in the permeate flow rate to changes in the feed pressure, was also investigated. The results show that the DMC offers a substantially better performance than classical PI controllers. Also, it has good robustness characteristics. It continued to produce good control for even large changes, ±30%, in the gain relating the product flow rate to feed pressure.</description><identifier>ISSN: 0011-9164</identifier><identifier>EISSN: 1873-4464</identifier><identifier>DOI: 10.1016/j.desal.2005.10.033</identifier><identifier>CODEN: DSLNAH</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Chemical engineering ; Drinking water and swimming-pool water. Desalination ; Dynamic matrix control ; Exact sciences and technology ; Membrane separation (reverse osmosis, dialysis...) ; Model predictive control ; Pollution ; Reverse osmosis ; Water desalination ; Water treatment and pollution</subject><ispartof>Desalination, 2006-06, Vol.194 (1), p.268-280</ispartof><rights>2006 Elsevier B.V.</rights><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c364t-4ede5d8abfd0b5279f4ea403b47e06bf95d20a60e88afac6ac4e37aa5385fea33</citedby><cites>FETCH-LOGICAL-c364t-4ede5d8abfd0b5279f4ea403b47e06bf95d20a60e88afac6ac4e37aa5385fea33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0011916406003808$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=17847819$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Abbas, Abderrahim</creatorcontrib><title>Model predictive control of a reverse osmosis desalination unit</title><title>Desalination</title><description>Model predictive control (MPC) has established itself as the leading form of advanced control in the process industry. One of the most popular MPC strategies is the dynamic matrix control (DMC) algorithm. In this paper, the DMC algorithm with/without constraints is used for the control of a simulated reverse osmosis water desalination unit based on a hollow-fiber membrane. The controller was tuned using a recently presented simple method. Two cases were considered. In the first, the permeate flux was controlled by manipulating feed pressure. The second was a multivariable case in which both the permeate flow rate and conductivity (a measure of quality) are controlled by adjusting the feed pressure and pH. The performances of the DMC were analyzed and compared to those obtained from a control system based on classical PI controllers. The sensitivity of the DMC to changes in a key plant parameter, namely the gain-relating changes in the permeate flow rate to changes in the feed pressure, was also investigated. The results show that the DMC offers a substantially better performance than classical PI controllers. Also, it has good robustness characteristics. It continued to produce good control for even large changes, ±30%, in the gain relating the product flow rate to feed pressure.</description><subject>Applied sciences</subject><subject>Chemical engineering</subject><subject>Drinking water and swimming-pool water. Desalination</subject><subject>Dynamic matrix control</subject><subject>Exact sciences and technology</subject><subject>Membrane separation (reverse osmosis, dialysis...)</subject><subject>Model predictive control</subject><subject>Pollution</subject><subject>Reverse osmosis</subject><subject>Water desalination</subject><subject>Water treatment and pollution</subject><issn>0011-9164</issn><issn>1873-4464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9UMtKAzEUDaJgrX6Bm2x0NzWZZCaZhYgUX1Bxo-twJ7mBlOmkJtOCf-_0Ae5cXe7hPDiHkGvOZpzx-m45c5ihm5WMVSMyY0KckAnXShRS1vKUTBjjvGh4Lc_JRc7L8S0bISbk4T067Og6oQt2CFukNvZDih2NngJNuMWUkca8ijlkuo8JPQwh9nTTh-GSnHnoMl4d75R8PT99zl-LxcfL2_xxUVhRy6GQ6LByGlrvWFuVqvESQTLRSoWsbn1TuZJBzVBr8GBrsBKFAqiErjyCEFNye_Bdp_i9wTyYVcgWuw56jJtsuOKN1EqPRHEg2hRzTujNOoUVpB_DmdmNZZZm38LsxtqB41ij6uZoD9lC5xP0NuQ_qdJSad6MvPsDD8eu24DJZBuwt-N6Ce1gXAz_5vwCkTuB8Q</recordid><startdate>20060610</startdate><enddate>20060610</enddate><creator>Abbas, Abderrahim</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7UA</scope><scope>C1K</scope></search><sort><creationdate>20060610</creationdate><title>Model predictive control of a reverse osmosis desalination unit</title><author>Abbas, Abderrahim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-4ede5d8abfd0b5279f4ea403b47e06bf95d20a60e88afac6ac4e37aa5385fea33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Applied sciences</topic><topic>Chemical engineering</topic><topic>Drinking water and swimming-pool water. Desalination</topic><topic>Dynamic matrix control</topic><topic>Exact sciences and technology</topic><topic>Membrane separation (reverse osmosis, dialysis...)</topic><topic>Model predictive control</topic><topic>Pollution</topic><topic>Reverse osmosis</topic><topic>Water desalination</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abbas, Abderrahim</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Desalination</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abbas, Abderrahim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Model predictive control of a reverse osmosis desalination unit</atitle><jtitle>Desalination</jtitle><date>2006-06-10</date><risdate>2006</risdate><volume>194</volume><issue>1</issue><spage>268</spage><epage>280</epage><pages>268-280</pages><issn>0011-9164</issn><eissn>1873-4464</eissn><coden>DSLNAH</coden><abstract>Model predictive control (MPC) has established itself as the leading form of advanced control in the process industry. One of the most popular MPC strategies is the dynamic matrix control (DMC) algorithm. In this paper, the DMC algorithm with/without constraints is used for the control of a simulated reverse osmosis water desalination unit based on a hollow-fiber membrane. The controller was tuned using a recently presented simple method. Two cases were considered. In the first, the permeate flux was controlled by manipulating feed pressure. The second was a multivariable case in which both the permeate flow rate and conductivity (a measure of quality) are controlled by adjusting the feed pressure and pH. The performances of the DMC were analyzed and compared to those obtained from a control system based on classical PI controllers. The sensitivity of the DMC to changes in a key plant parameter, namely the gain-relating changes in the permeate flow rate to changes in the feed pressure, was also investigated. The results show that the DMC offers a substantially better performance than classical PI controllers. Also, it has good robustness characteristics. It continued to produce good control for even large changes, ±30%, in the gain relating the product flow rate to feed pressure.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.desal.2005.10.033</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0011-9164 |
ispartof | Desalination, 2006-06, Vol.194 (1), p.268-280 |
issn | 0011-9164 1873-4464 |
language | eng |
recordid | cdi_proquest_miscellaneous_17194878 |
source | Elsevier ScienceDirect Journals |
subjects | Applied sciences Chemical engineering Drinking water and swimming-pool water. Desalination Dynamic matrix control Exact sciences and technology Membrane separation (reverse osmosis, dialysis...) Model predictive control Pollution Reverse osmosis Water desalination Water treatment and pollution |
title | Model predictive control of a reverse osmosis desalination unit |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T08%3A25%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Model%20predictive%20control%20of%20a%20reverse%20osmosis%20desalination%20unit&rft.jtitle=Desalination&rft.au=Abbas,%20Abderrahim&rft.date=2006-06-10&rft.volume=194&rft.issue=1&rft.spage=268&rft.epage=280&rft.pages=268-280&rft.issn=0011-9164&rft.eissn=1873-4464&rft.coden=DSLNAH&rft_id=info:doi/10.1016/j.desal.2005.10.033&rft_dat=%3Cproquest_cross%3E17194878%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17194878&rft_id=info:pmid/&rft_els_id=S0011916406003808&rfr_iscdi=true |