Determination of salt content in various depth of pork chop by electrical impedance spectroscopy
The salt concentration was determined inside of pork chop both by electrical impedance spectroscopy and by a conventional chemical method (according to Mohr). The pork chop in various depths (4 mm, 10 mm, 20 mm and 25 mm) was punctured with two stainless steel electrodes. The length of electrodes wa...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2013-01, Vol.434 (1), p.12094-4 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | 1 |
container_start_page | 12094 |
container_title | Journal of physics. Conference series |
container_volume | 434 |
creator | Kaltenecker, P Szöllösi, D Friedrich, L Vozáry, E |
description | The salt concentration was determined inside of pork chop both by electrical impedance spectroscopy and by a conventional chemical method (according to Mohr). The pork chop in various depths (4 mm, 10 mm, 20 mm and 25 mm) was punctured with two stainless steel electrodes. The length of electrodes was 60 mm, and they were insulated along the length except 1 cm section on the end, so the measurement of impedance was realized in various depths. The magnitude and phase angle of impedance were measured with a HP 4284A and a HP 4285A LCR meters from 30 Hz up to 1 MHz and from 75 kHz up to 30 MHz frequency range, respectively at 1 V voltage. The distance between the electrodes was 1 cm. The impedance magnitude decreased as the salt concentration increased. The magnitude of open-short corrected impedance values at various frequencies (10 kHz, 100 kHz, 125 kHz, 1.1 MHz and 8 MHz) showed a good correlation with salt content determined by chemical procedure. The electrical impedance spectroscopy seems a prospective method for determination the salt concentration inside the meat in various depths during the curing procedure. |
doi_str_mv | 10.1088/1742-6596/434/1/012094 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1718925965</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2577446406</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-93ba847233a6c38709fdd6085c41bce9e00addb16ef6111bbcadc59347dfaa2c3</originalsourceid><addsrcrecordid>eNpdkE1LxDAQQIsouK7-BQl48VKbNGnSHmX9hAUveo5pkrJZ2yQmWWH_vSkre3AuM8w8hplXFNcI3iHYthVipC5p09GKYFKhCqIaduSkWBwHp8e6bc-Lixi3EOIcbFF8Puikw2SsSMZZ4AYQxZiAdDZpm4Cx4EcE43YRKO3TZga8C19AbpwH_R7oUcsUjBQjMJPXSlipQfRz00Xp_P6yOBvEGPXVX14WH0-P76uXcv32_Lq6X5cSU5LKDveiJazGWFCJWwa7QSkK20YS1EvdaQiFUj2ieqAIob6XQsmmw4SpQYha4mVxe9jrg_ve6Zj4ZKLU4yiszudzxFDb1VlGk9Gbf-jW7YLN1_G6YYwQSiDNFD1QMn8Sgx64D2YSYc8R5LN4Pjvls1-exXPED-LxLwSnd7g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2577446406</pqid></control><display><type>article</type><title>Determination of salt content in various depth of pork chop by electrical impedance spectroscopy</title><source>IOP Publishing Free Content</source><source>EZB-FREE-00999 freely available EZB journals</source><source>IOPscience extra</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Kaltenecker, P ; Szöllösi, D ; Friedrich, L ; Vozáry, E</creator><creatorcontrib>Kaltenecker, P ; Szöllösi, D ; Friedrich, L ; Vozáry, E</creatorcontrib><description>The salt concentration was determined inside of pork chop both by electrical impedance spectroscopy and by a conventional chemical method (according to Mohr). The pork chop in various depths (4 mm, 10 mm, 20 mm and 25 mm) was punctured with two stainless steel electrodes. The length of electrodes was 60 mm, and they were insulated along the length except 1 cm section on the end, so the measurement of impedance was realized in various depths. The magnitude and phase angle of impedance were measured with a HP 4284A and a HP 4285A LCR meters from 30 Hz up to 1 MHz and from 75 kHz up to 30 MHz frequency range, respectively at 1 V voltage. The distance between the electrodes was 1 cm. The impedance magnitude decreased as the salt concentration increased. The magnitude of open-short corrected impedance values at various frequencies (10 kHz, 100 kHz, 125 kHz, 1.1 MHz and 8 MHz) showed a good correlation with salt content determined by chemical procedure. The electrical impedance spectroscopy seems a prospective method for determination the salt concentration inside the meat in various depths during the curing procedure.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/434/1/012094</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Electrical impedance ; Electrodes ; Frequency ranges ; Impedance ; Impedance spectroscopy ; Measuring instruments ; Meat ; Physics ; Pork ; Spectroscopy ; Spectrum analysis ; Stainless steels ; Voltage</subject><ispartof>Journal of physics. Conference series, 2013-01, Vol.434 (1), p.12094-4</ispartof><rights>Copyright IOP Publishing Apr 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c364t-93ba847233a6c38709fdd6085c41bce9e00addb16ef6111bbcadc59347dfaa2c3</citedby><cites>FETCH-LOGICAL-c364t-93ba847233a6c38709fdd6085c41bce9e00addb16ef6111bbcadc59347dfaa2c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Kaltenecker, P</creatorcontrib><creatorcontrib>Szöllösi, D</creatorcontrib><creatorcontrib>Friedrich, L</creatorcontrib><creatorcontrib>Vozáry, E</creatorcontrib><title>Determination of salt content in various depth of pork chop by electrical impedance spectroscopy</title><title>Journal of physics. Conference series</title><description>The salt concentration was determined inside of pork chop both by electrical impedance spectroscopy and by a conventional chemical method (according to Mohr). The pork chop in various depths (4 mm, 10 mm, 20 mm and 25 mm) was punctured with two stainless steel electrodes. The length of electrodes was 60 mm, and they were insulated along the length except 1 cm section on the end, so the measurement of impedance was realized in various depths. The magnitude and phase angle of impedance were measured with a HP 4284A and a HP 4285A LCR meters from 30 Hz up to 1 MHz and from 75 kHz up to 30 MHz frequency range, respectively at 1 V voltage. The distance between the electrodes was 1 cm. The impedance magnitude decreased as the salt concentration increased. The magnitude of open-short corrected impedance values at various frequencies (10 kHz, 100 kHz, 125 kHz, 1.1 MHz and 8 MHz) showed a good correlation with salt content determined by chemical procedure. The electrical impedance spectroscopy seems a prospective method for determination the salt concentration inside the meat in various depths during the curing procedure.</description><subject>Electrical impedance</subject><subject>Electrodes</subject><subject>Frequency ranges</subject><subject>Impedance</subject><subject>Impedance spectroscopy</subject><subject>Measuring instruments</subject><subject>Meat</subject><subject>Physics</subject><subject>Pork</subject><subject>Spectroscopy</subject><subject>Spectrum analysis</subject><subject>Stainless steels</subject><subject>Voltage</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkE1LxDAQQIsouK7-BQl48VKbNGnSHmX9hAUveo5pkrJZ2yQmWWH_vSkre3AuM8w8hplXFNcI3iHYthVipC5p09GKYFKhCqIaduSkWBwHp8e6bc-Lixi3EOIcbFF8Puikw2SsSMZZ4AYQxZiAdDZpm4Cx4EcE43YRKO3TZga8C19AbpwH_R7oUcsUjBQjMJPXSlipQfRz00Xp_P6yOBvEGPXVX14WH0-P76uXcv32_Lq6X5cSU5LKDveiJazGWFCJWwa7QSkK20YS1EvdaQiFUj2ieqAIob6XQsmmw4SpQYha4mVxe9jrg_ve6Zj4ZKLU4yiszudzxFDb1VlGk9Gbf-jW7YLN1_G6YYwQSiDNFD1QMn8Sgx64D2YSYc8R5LN4Pjvls1-exXPED-LxLwSnd7g</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Kaltenecker, P</creator><creator>Szöllösi, D</creator><creator>Friedrich, L</creator><creator>Vozáry, E</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7U5</scope><scope>8BQ</scope><scope>JG9</scope></search><sort><creationdate>20130101</creationdate><title>Determination of salt content in various depth of pork chop by electrical impedance spectroscopy</title><author>Kaltenecker, P ; Szöllösi, D ; Friedrich, L ; Vozáry, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-93ba847233a6c38709fdd6085c41bce9e00addb16ef6111bbcadc59347dfaa2c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Electrical impedance</topic><topic>Electrodes</topic><topic>Frequency ranges</topic><topic>Impedance</topic><topic>Impedance spectroscopy</topic><topic>Measuring instruments</topic><topic>Meat</topic><topic>Physics</topic><topic>Pork</topic><topic>Spectroscopy</topic><topic>Spectrum analysis</topic><topic>Stainless steels</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kaltenecker, P</creatorcontrib><creatorcontrib>Szöllösi, D</creatorcontrib><creatorcontrib>Friedrich, L</creatorcontrib><creatorcontrib>Vozáry, E</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Materials Research Database</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kaltenecker, P</au><au>Szöllösi, D</au><au>Friedrich, L</au><au>Vozáry, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of salt content in various depth of pork chop by electrical impedance spectroscopy</atitle><jtitle>Journal of physics. Conference series</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>434</volume><issue>1</issue><spage>12094</spage><epage>4</epage><pages>12094-4</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>The salt concentration was determined inside of pork chop both by electrical impedance spectroscopy and by a conventional chemical method (according to Mohr). The pork chop in various depths (4 mm, 10 mm, 20 mm and 25 mm) was punctured with two stainless steel electrodes. The length of electrodes was 60 mm, and they were insulated along the length except 1 cm section on the end, so the measurement of impedance was realized in various depths. The magnitude and phase angle of impedance were measured with a HP 4284A and a HP 4285A LCR meters from 30 Hz up to 1 MHz and from 75 kHz up to 30 MHz frequency range, respectively at 1 V voltage. The distance between the electrodes was 1 cm. The impedance magnitude decreased as the salt concentration increased. The magnitude of open-short corrected impedance values at various frequencies (10 kHz, 100 kHz, 125 kHz, 1.1 MHz and 8 MHz) showed a good correlation with salt content determined by chemical procedure. The electrical impedance spectroscopy seems a prospective method for determination the salt concentration inside the meat in various depths during the curing procedure.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/434/1/012094</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2013-01, Vol.434 (1), p.12094-4 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_miscellaneous_1718925965 |
source | IOP Publishing Free Content; EZB-FREE-00999 freely available EZB journals; IOPscience extra; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | Electrical impedance Electrodes Frequency ranges Impedance Impedance spectroscopy Measuring instruments Meat Physics Pork Spectroscopy Spectrum analysis Stainless steels Voltage |
title | Determination of salt content in various depth of pork chop by electrical impedance spectroscopy |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T16%3A36%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20salt%20content%20in%20various%20depth%20of%20pork%20chop%20by%20electrical%20impedance%20spectroscopy&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Kaltenecker,%20P&rft.date=2013-01-01&rft.volume=434&rft.issue=1&rft.spage=12094&rft.epage=4&rft.pages=12094-4&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/434/1/012094&rft_dat=%3Cproquest_cross%3E2577446406%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2577446406&rft_id=info:pmid/&rfr_iscdi=true |