Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children

To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of aerosol medicine 2015-10, Vol.28 (5), p.320-333
Hauptverfasser: Laube, Beth L, Sharpless, Gail, Vikani, Ami R, Harrand, Vincent, Zinreich, Simeon J, Sedberry, Keith, Knaus, Darin, Barry, James, Papania, Mark
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 333
container_issue 5
container_start_page 320
container_title Journal of aerosol medicine
container_volume 28
creator Laube, Beth L
Sharpless, Gail
Vikani, Ami R
Harrand, Vincent
Zinreich, Simeon J
Sedberry, Keith
Knaus, Darin
Barry, James
Papania, Mark
description To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses in anatomically-correct physical models based on CT scans of 2-, 5-, and 12-year-old children with normal, intranasal airways. Models included a removable anterior nose (AN) with exterior facial features and interior nasal vestibule and nasal valve area and a main nasal airway (MNA), subdivided into upper (superior turbinates and olfactory area), middle (middle turbinates), and lower (inferior turbinates and nasopharynx) thirds. Aerosol was generated from distilled water admixed with (99m)technetium pertechnetate and administered during static airflow by AS inserted inside the right nostril (eight runs/model), or outside the right nostril (six runs/model). Mean aerosol Dv(50) ± standard deviation was 67.8 ± 24.7 μm. Deposition was quantified by 2D gamma scintigraphy and expressed as percentage of the emitted dose. When placed inside the nostril, mean (± standard deviation) deposition within the MNA was significantly less in the 2-year-old, compared to the 5- and 12-year-old, averaging 46.8 ± 33.8% (AN:55.4 ± 29.9%), 75.4 ± 26.7% (AN:23.3 ± 13.6%), and 72.1 ± 18.5% (AN:25.8 ± 18.5%), respectively (p
doi_str_mv 10.1089/jamp.2014.1174
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1718914697</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1718914697</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-7b1f27dec30e1976ce859c200fe6cd8836e51d4cb8c21edd660ecfc578a3d20a3</originalsourceid><addsrcrecordid>eNpdkbFu2zAQhokiQe0mXTMWBLJkqBweKYnSaDhtGiBBlmToJNDkCZFBkSopDd77JH20PEkoxPHQ4XA3fP_d4f8JuQC2AlbV1zvVDyvOIF8ByPwTWUKdQ8YlEyfHGWBBvsS4Y6yEvBSfyYIXpawrYEsy3LkxKKeisvQGBx-7sfOO-pautZ7iENT-9e8_usbgo7e0c3Tt1Oj7Titr93TjQ0A90gdv0MZZxrPvtEilnKHAs9-oQvZoDd28dNYEdOfktFU24tdDPyPPP388bX5l94-3d5v1faYFF2Mmt9ByaVALhlDLUmNV1Joz1mKpTVWJEgswud5WmgMaU5YMdasLWSlhOFPijFy97x2C_zNhHJu-ixqtVQ79FBuQUNXJjlom9PI_dOen4NJ3iUonIc-hTtTqndLJihiwbYbQ9SrsG2DNnEUzZ9HMWTRzFknw7bB22vZojviH-eINpgWEjA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1720014419</pqid></control><display><type>article</type><title>Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Laube, Beth L ; Sharpless, Gail ; Vikani, Ami R ; Harrand, Vincent ; Zinreich, Simeon J ; Sedberry, Keith ; Knaus, Darin ; Barry, James ; Papania, Mark</creator><creatorcontrib>Laube, Beth L ; Sharpless, Gail ; Vikani, Ami R ; Harrand, Vincent ; Zinreich, Simeon J ; Sedberry, Keith ; Knaus, Darin ; Barry, James ; Papania, Mark</creatorcontrib><description>To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses in anatomically-correct physical models based on CT scans of 2-, 5-, and 12-year-old children with normal, intranasal airways. Models included a removable anterior nose (AN) with exterior facial features and interior nasal vestibule and nasal valve area and a main nasal airway (MNA), subdivided into upper (superior turbinates and olfactory area), middle (middle turbinates), and lower (inferior turbinates and nasopharynx) thirds. Aerosol was generated from distilled water admixed with (99m)technetium pertechnetate and administered during static airflow by AS inserted inside the right nostril (eight runs/model), or outside the right nostril (six runs/model). Mean aerosol Dv(50) ± standard deviation was 67.8 ± 24.7 μm. Deposition was quantified by 2D gamma scintigraphy and expressed as percentage of the emitted dose. When placed inside the nostril, mean (± standard deviation) deposition within the MNA was significantly less in the 2-year-old, compared to the 5- and 12-year-old, averaging 46.8 ± 33.8% (AN:55.4 ± 29.9%), 75.4 ± 26.7% (AN:23.3 ± 13.6%), and 72.1 ± 18.5% (AN:25.8 ± 18.5%), respectively (p&lt;0.05). When placed outside the nostril, MNA was significantly less in the 2- and 5-year-old compared to the 12-year-old, with 1.4 ± 2.5% (AN:69.7 ± 40.7%), 7.4 ± 9.0% (AN:77.8 ± 32.8%), and 21.1 ± 29.1% (AN:29.2 ± 19.3%), respectively (p&lt;0.05). Deposition in the MNA of all age models was highest when AS was placed inside the nostril (p&lt;0.05). Deposition in the lower third was significantly increased for the 5- and 12-year-old and in the middle third of the 5-year-old when AS was placed inside the nostril. These results indicate that age and device placement play important roles in terms of intranasal deposition, when administering aerosol with Accuspray(™) to children.</description><identifier>ISSN: 1941-2711</identifier><identifier>EISSN: 1941-2703</identifier><identifier>DOI: 10.1089/jamp.2014.1174</identifier><identifier>PMID: 25679810</identifier><language>eng</language><publisher>United States: Mary Ann Liebert, Inc</publisher><subject>Aerosols ; Age Factors ; Child ; Child, Preschool ; Health technology assessment ; Humans ; Models, Anatomic ; Nebulizers and Vaporizers ; Nose - metabolism ; Particle Size ; Radionuclide Imaging ; Tomography, X-Ray Computed</subject><ispartof>Journal of aerosol medicine, 2015-10, Vol.28 (5), p.320-333</ispartof><rights>(©) Copyright 2015, Mary Ann Liebert, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-7b1f27dec30e1976ce859c200fe6cd8836e51d4cb8c21edd660ecfc578a3d20a3</citedby><cites>FETCH-LOGICAL-c323t-7b1f27dec30e1976ce859c200fe6cd8836e51d4cb8c21edd660ecfc578a3d20a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25679810$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Laube, Beth L</creatorcontrib><creatorcontrib>Sharpless, Gail</creatorcontrib><creatorcontrib>Vikani, Ami R</creatorcontrib><creatorcontrib>Harrand, Vincent</creatorcontrib><creatorcontrib>Zinreich, Simeon J</creatorcontrib><creatorcontrib>Sedberry, Keith</creatorcontrib><creatorcontrib>Knaus, Darin</creatorcontrib><creatorcontrib>Barry, James</creatorcontrib><creatorcontrib>Papania, Mark</creatorcontrib><title>Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children</title><title>Journal of aerosol medicine</title><addtitle>J Aerosol Med Pulm Drug Deliv</addtitle><description>To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses in anatomically-correct physical models based on CT scans of 2-, 5-, and 12-year-old children with normal, intranasal airways. Models included a removable anterior nose (AN) with exterior facial features and interior nasal vestibule and nasal valve area and a main nasal airway (MNA), subdivided into upper (superior turbinates and olfactory area), middle (middle turbinates), and lower (inferior turbinates and nasopharynx) thirds. Aerosol was generated from distilled water admixed with (99m)technetium pertechnetate and administered during static airflow by AS inserted inside the right nostril (eight runs/model), or outside the right nostril (six runs/model). Mean aerosol Dv(50) ± standard deviation was 67.8 ± 24.7 μm. Deposition was quantified by 2D gamma scintigraphy and expressed as percentage of the emitted dose. When placed inside the nostril, mean (± standard deviation) deposition within the MNA was significantly less in the 2-year-old, compared to the 5- and 12-year-old, averaging 46.8 ± 33.8% (AN:55.4 ± 29.9%), 75.4 ± 26.7% (AN:23.3 ± 13.6%), and 72.1 ± 18.5% (AN:25.8 ± 18.5%), respectively (p&lt;0.05). When placed outside the nostril, MNA was significantly less in the 2- and 5-year-old compared to the 12-year-old, with 1.4 ± 2.5% (AN:69.7 ± 40.7%), 7.4 ± 9.0% (AN:77.8 ± 32.8%), and 21.1 ± 29.1% (AN:29.2 ± 19.3%), respectively (p&lt;0.05). Deposition in the MNA of all age models was highest when AS was placed inside the nostril (p&lt;0.05). Deposition in the lower third was significantly increased for the 5- and 12-year-old and in the middle third of the 5-year-old when AS was placed inside the nostril. These results indicate that age and device placement play important roles in terms of intranasal deposition, when administering aerosol with Accuspray(™) to children.</description><subject>Aerosols</subject><subject>Age Factors</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Health technology assessment</subject><subject>Humans</subject><subject>Models, Anatomic</subject><subject>Nebulizers and Vaporizers</subject><subject>Nose - metabolism</subject><subject>Particle Size</subject><subject>Radionuclide Imaging</subject><subject>Tomography, X-Ray Computed</subject><issn>1941-2711</issn><issn>1941-2703</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNpdkbFu2zAQhokiQe0mXTMWBLJkqBweKYnSaDhtGiBBlmToJNDkCZFBkSopDd77JH20PEkoxPHQ4XA3fP_d4f8JuQC2AlbV1zvVDyvOIF8ByPwTWUKdQ8YlEyfHGWBBvsS4Y6yEvBSfyYIXpawrYEsy3LkxKKeisvQGBx-7sfOO-pautZ7iENT-9e8_usbgo7e0c3Tt1Oj7Titr93TjQ0A90gdv0MZZxrPvtEilnKHAs9-oQvZoDd28dNYEdOfktFU24tdDPyPPP388bX5l94-3d5v1faYFF2Mmt9ByaVALhlDLUmNV1Joz1mKpTVWJEgswud5WmgMaU5YMdasLWSlhOFPijFy97x2C_zNhHJu-ixqtVQ79FBuQUNXJjlom9PI_dOen4NJ3iUonIc-hTtTqndLJihiwbYbQ9SrsG2DNnEUzZ9HMWTRzFknw7bB22vZojviH-eINpgWEjA</recordid><startdate>201510</startdate><enddate>201510</enddate><creator>Laube, Beth L</creator><creator>Sharpless, Gail</creator><creator>Vikani, Ami R</creator><creator>Harrand, Vincent</creator><creator>Zinreich, Simeon J</creator><creator>Sedberry, Keith</creator><creator>Knaus, Darin</creator><creator>Barry, James</creator><creator>Papania, Mark</creator><general>Mary Ann Liebert, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>201510</creationdate><title>Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children</title><author>Laube, Beth L ; Sharpless, Gail ; Vikani, Ami R ; Harrand, Vincent ; Zinreich, Simeon J ; Sedberry, Keith ; Knaus, Darin ; Barry, James ; Papania, Mark</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-7b1f27dec30e1976ce859c200fe6cd8836e51d4cb8c21edd660ecfc578a3d20a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aerosols</topic><topic>Age Factors</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Health technology assessment</topic><topic>Humans</topic><topic>Models, Anatomic</topic><topic>Nebulizers and Vaporizers</topic><topic>Nose - metabolism</topic><topic>Particle Size</topic><topic>Radionuclide Imaging</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Laube, Beth L</creatorcontrib><creatorcontrib>Sharpless, Gail</creatorcontrib><creatorcontrib>Vikani, Ami R</creatorcontrib><creatorcontrib>Harrand, Vincent</creatorcontrib><creatorcontrib>Zinreich, Simeon J</creatorcontrib><creatorcontrib>Sedberry, Keith</creatorcontrib><creatorcontrib>Knaus, Darin</creatorcontrib><creatorcontrib>Barry, James</creatorcontrib><creatorcontrib>Papania, Mark</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of aerosol medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Laube, Beth L</au><au>Sharpless, Gail</au><au>Vikani, Ami R</au><au>Harrand, Vincent</au><au>Zinreich, Simeon J</au><au>Sedberry, Keith</au><au>Knaus, Darin</au><au>Barry, James</au><au>Papania, Mark</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children</atitle><jtitle>Journal of aerosol medicine</jtitle><addtitle>J Aerosol Med Pulm Drug Deliv</addtitle><date>2015-10</date><risdate>2015</risdate><volume>28</volume><issue>5</issue><spage>320</spage><epage>333</epage><pages>320-333</pages><issn>1941-2711</issn><eissn>1941-2703</eissn><abstract>To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses in anatomically-correct physical models based on CT scans of 2-, 5-, and 12-year-old children with normal, intranasal airways. Models included a removable anterior nose (AN) with exterior facial features and interior nasal vestibule and nasal valve area and a main nasal airway (MNA), subdivided into upper (superior turbinates and olfactory area), middle (middle turbinates), and lower (inferior turbinates and nasopharynx) thirds. Aerosol was generated from distilled water admixed with (99m)technetium pertechnetate and administered during static airflow by AS inserted inside the right nostril (eight runs/model), or outside the right nostril (six runs/model). Mean aerosol Dv(50) ± standard deviation was 67.8 ± 24.7 μm. Deposition was quantified by 2D gamma scintigraphy and expressed as percentage of the emitted dose. When placed inside the nostril, mean (± standard deviation) deposition within the MNA was significantly less in the 2-year-old, compared to the 5- and 12-year-old, averaging 46.8 ± 33.8% (AN:55.4 ± 29.9%), 75.4 ± 26.7% (AN:23.3 ± 13.6%), and 72.1 ± 18.5% (AN:25.8 ± 18.5%), respectively (p&lt;0.05). When placed outside the nostril, MNA was significantly less in the 2- and 5-year-old compared to the 12-year-old, with 1.4 ± 2.5% (AN:69.7 ± 40.7%), 7.4 ± 9.0% (AN:77.8 ± 32.8%), and 21.1 ± 29.1% (AN:29.2 ± 19.3%), respectively (p&lt;0.05). Deposition in the MNA of all age models was highest when AS was placed inside the nostril (p&lt;0.05). Deposition in the lower third was significantly increased for the 5- and 12-year-old and in the middle third of the 5-year-old when AS was placed inside the nostril. These results indicate that age and device placement play important roles in terms of intranasal deposition, when administering aerosol with Accuspray(™) to children.</abstract><cop>United States</cop><pub>Mary Ann Liebert, Inc</pub><pmid>25679810</pmid><doi>10.1089/jamp.2014.1174</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1941-2711
ispartof Journal of aerosol medicine, 2015-10, Vol.28 (5), p.320-333
issn 1941-2711
1941-2703
language eng
recordid cdi_proquest_miscellaneous_1718914697
source MEDLINE; Alma/SFX Local Collection
subjects Aerosols
Age Factors
Child
Child, Preschool
Health technology assessment
Humans
Models, Anatomic
Nebulizers and Vaporizers
Nose - metabolism
Particle Size
Radionuclide Imaging
Tomography, X-Ray Computed
title Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T00%3A45%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Intranasal%20Deposition%20of%20Accuspray%E2%84%A2%20Aerosol%20in%20Anatomically%20Correct%20Models%20of%202-,%205-,%20and%2012-Year-Old%20Children&rft.jtitle=Journal%20of%20aerosol%20medicine&rft.au=Laube,%20Beth%20L&rft.date=2015-10&rft.volume=28&rft.issue=5&rft.spage=320&rft.epage=333&rft.pages=320-333&rft.issn=1941-2711&rft.eissn=1941-2703&rft_id=info:doi/10.1089/jamp.2014.1174&rft_dat=%3Cproquest_cross%3E1718914697%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1720014419&rft_id=info:pmid/25679810&rfr_iscdi=true