Allergic reaction to ortho‐phthalaldehyde following flexible laryngoscopy

Flexible laryngoscopes are common outpatient surveillance tools. Cleansing of these scopes between patients must be quick, effective, and safe. One sterilant that largely meets these criteria is ortho‐phthalaldehyde (OPA); however, infrequently, patients may develop allergic reactions to it. We pres...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Laryngoscope 2015-10, Vol.125 (10), p.2349-2352
Hauptverfasser: Atiyeh, Kimberly, Chitkara, Ajay, Achlatis, Stratos, Branski, Ryan C., Amin, Milan R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Flexible laryngoscopes are common outpatient surveillance tools. Cleansing of these scopes between patients must be quick, effective, and safe. One sterilant that largely meets these criteria is ortho‐phthalaldehyde (OPA); however, infrequently, patients may develop allergic reactions to it. We present three cases of patients who developed significant allergic reactions following repeated laryngoscopic examinations. Subsequent intradermal allergy testing confirmed sensitivity to OPA. In addition, we reviewed the current literature, which includes 17 similar reactions reported in nine patients across disciplines. Allergic reaction to OPA is uncommon, but a potentially under‐reported severe complication of repeated endoscopy. Laryngoscope, 125:2349–2352, 2015
ISSN:0023-852X
1531-4995
DOI:10.1002/lary.25421