Reclamation of dairy wastewater using ultrafiltration process
Large amounts of water are daily used in dairy industries for different parts of their services such as chilling, cooling, steam production, pasteurizing, etc. This consumption generates a huge quantity of wastewaters which could be reused after performed treatment. In the present work, a real sampl...
Gespeichert in:
Veröffentlicht in: | Desalination and water treatment 2015-07, Vol.55 (2), p.297-303 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 303 |
---|---|
container_issue | 2 |
container_start_page | 297 |
container_title | Desalination and water treatment |
container_volume | 55 |
creator | Bennani, Cheïma Fersi Ousji, Besma Ennigrou, Dorra Jellouli |
description | Large amounts of water are daily used in dairy industries for different parts of their services such as chilling, cooling, steam production, pasteurizing, etc. This consumption generates a huge quantity of wastewaters which could be reused after performed treatment. In the present work, a real sample of dairy wastewater was treated using ultrafiltration (UF) and process efficiency and permeate quality were improved by operating under optimum conditions of transmembrane pressure (TMP) and volume reduction factor (VRF). More than 99% of retention rate were observed for turbidity and the BDO5, more than 80% for suspended matter, and 95% for proteins with an optimal TMP fixed at 2.5 bar. Moreover, a reduction of 40 and 55% was recorded for conductivity and the total dissolved salts, respectively. Rather important retention rates varying from 95 to 99% for the majority of the analyzed parameters were observed for a VRF range varying from 1.11 to 2.5. A recovery of 58% of the dairy effluent is possible after treatment by UF using the PES-5 membrane. The permeate quality obtained in optimal TMP and VRF allows the industry to reject its effluents into the river without risks of contamination (according to Tunisian standard for wastewater discharge NT106-02) and to reuse or recycle them during the process (according to Tunisian standard for reusing treated wastewater NT106-03). |
doi_str_mv | 10.1080/19443994.2014.913996 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1709746227</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1944398624047921</els_id><sourcerecordid>1701474938</sourcerecordid><originalsourceid>FETCH-LOGICAL-c470t-636965df2a3c83036953b359fbf47f0586d3c88f1c7bb59ec7682867797da75b3</originalsourceid><addsrcrecordid>eNqNkU1LxDAQhoMouKz7DzwUvHhpTZrvg4IsfsGCIHoOaZpIlm67Jq3L_ntTqyAexDlkJjPPzJC8AJwiWCAo4AWShGApSVFCRAqJUswOwGxM51gKdvgjPgaLGNcwGSWcknIGLp-safRG975rs85ltfZhn-107O1O9zZkQ_TtazY0fdDOj-cnuQ2dsTGegCOnm2gXX34OXm5vnpf3-erx7mF5vcoN4bDPGWaS0dqVGhuBYbpRXGEqXeUId5AKVqeCcMjwqqLSGs5EKRjnktea0wrPwfk0N-19G2zs1cZHY5tGt7YbokIcSk5YWfL_oIhwIrFI6NkvdN0NoU0PUYgJwQgTcqTIRJnQxRisU9vgNzrsFYJqVEB9K6BGBdSkQGq7mtps-pd3b4OKxtvW2NoHa3pVd_7vAR8sQYqJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1688646898</pqid></control><display><type>article</type><title>Reclamation of dairy wastewater using ultrafiltration process</title><source>Alma/SFX Local Collection</source><creator>Bennani, Cheïma Fersi ; Ousji, Besma ; Ennigrou, Dorra Jellouli</creator><creatorcontrib>Bennani, Cheïma Fersi ; Ousji, Besma ; Ennigrou, Dorra Jellouli</creatorcontrib><description>Large amounts of water are daily used in dairy industries for different parts of their services such as chilling, cooling, steam production, pasteurizing, etc. This consumption generates a huge quantity of wastewaters which could be reused after performed treatment. In the present work, a real sample of dairy wastewater was treated using ultrafiltration (UF) and process efficiency and permeate quality were improved by operating under optimum conditions of transmembrane pressure (TMP) and volume reduction factor (VRF). More than 99% of retention rate were observed for turbidity and the BDO5, more than 80% for suspended matter, and 95% for proteins with an optimal TMP fixed at 2.5 bar. Moreover, a reduction of 40 and 55% was recorded for conductivity and the total dissolved salts, respectively. Rather important retention rates varying from 95 to 99% for the majority of the analyzed parameters were observed for a VRF range varying from 1.11 to 2.5. A recovery of 58% of the dairy effluent is possible after treatment by UF using the PES-5 membrane. The permeate quality obtained in optimal TMP and VRF allows the industry to reject its effluents into the river without risks of contamination (according to Tunisian standard for wastewater discharge NT106-02) and to reuse or recycle them during the process (according to Tunisian standard for reusing treated wastewater NT106-03).</description><identifier>ISSN: 1944-3986</identifier><identifier>ISSN: 1944-3994</identifier><identifier>EISSN: 1944-3986</identifier><identifier>DOI: 10.1080/19443994.2014.913996</identifier><language>eng</language><publisher>Abingdon: Elsevier Inc</publisher><subject>Cooling ; Dairy industry wastewaters ; Dairy wastewater ; Dissolved salts ; Effluents ; Optimization ; Pasteurizing ; Reclamation ; Reduction ; Retention ; Retention rates ; Turbidity ; Ultrafiltration ; Volume reduction factor ; Wastewater discharges ; Wastewater treatment</subject><ispartof>Desalination and water treatment, 2015-07, Vol.55 (2), p.297-303</ispartof><rights>2014 Elsevier Inc.</rights><rights>2014 Balaban Desalination Publications. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c470t-636965df2a3c83036953b359fbf47f0586d3c88f1c7bb59ec7682867797da75b3</citedby><cites>FETCH-LOGICAL-c470t-636965df2a3c83036953b359fbf47f0586d3c88f1c7bb59ec7682867797da75b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Bennani, Cheïma Fersi</creatorcontrib><creatorcontrib>Ousji, Besma</creatorcontrib><creatorcontrib>Ennigrou, Dorra Jellouli</creatorcontrib><title>Reclamation of dairy wastewater using ultrafiltration process</title><title>Desalination and water treatment</title><description>Large amounts of water are daily used in dairy industries for different parts of their services such as chilling, cooling, steam production, pasteurizing, etc. This consumption generates a huge quantity of wastewaters which could be reused after performed treatment. In the present work, a real sample of dairy wastewater was treated using ultrafiltration (UF) and process efficiency and permeate quality were improved by operating under optimum conditions of transmembrane pressure (TMP) and volume reduction factor (VRF). More than 99% of retention rate were observed for turbidity and the BDO5, more than 80% for suspended matter, and 95% for proteins with an optimal TMP fixed at 2.5 bar. Moreover, a reduction of 40 and 55% was recorded for conductivity and the total dissolved salts, respectively. Rather important retention rates varying from 95 to 99% for the majority of the analyzed parameters were observed for a VRF range varying from 1.11 to 2.5. A recovery of 58% of the dairy effluent is possible after treatment by UF using the PES-5 membrane. The permeate quality obtained in optimal TMP and VRF allows the industry to reject its effluents into the river without risks of contamination (according to Tunisian standard for wastewater discharge NT106-02) and to reuse or recycle them during the process (according to Tunisian standard for reusing treated wastewater NT106-03).</description><subject>Cooling</subject><subject>Dairy industry wastewaters</subject><subject>Dairy wastewater</subject><subject>Dissolved salts</subject><subject>Effluents</subject><subject>Optimization</subject><subject>Pasteurizing</subject><subject>Reclamation</subject><subject>Reduction</subject><subject>Retention</subject><subject>Retention rates</subject><subject>Turbidity</subject><subject>Ultrafiltration</subject><subject>Volume reduction factor</subject><subject>Wastewater discharges</subject><subject>Wastewater treatment</subject><issn>1944-3986</issn><issn>1944-3994</issn><issn>1944-3986</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqNkU1LxDAQhoMouKz7DzwUvHhpTZrvg4IsfsGCIHoOaZpIlm67Jq3L_ntTqyAexDlkJjPPzJC8AJwiWCAo4AWShGApSVFCRAqJUswOwGxM51gKdvgjPgaLGNcwGSWcknIGLp-safRG975rs85ltfZhn-107O1O9zZkQ_TtazY0fdDOj-cnuQ2dsTGegCOnm2gXX34OXm5vnpf3-erx7mF5vcoN4bDPGWaS0dqVGhuBYbpRXGEqXeUId5AKVqeCcMjwqqLSGs5EKRjnktea0wrPwfk0N-19G2zs1cZHY5tGt7YbokIcSk5YWfL_oIhwIrFI6NkvdN0NoU0PUYgJwQgTcqTIRJnQxRisU9vgNzrsFYJqVEB9K6BGBdSkQGq7mtps-pd3b4OKxtvW2NoHa3pVd_7vAR8sQYqJ</recordid><startdate>20150710</startdate><enddate>20150710</enddate><creator>Bennani, Cheïma Fersi</creator><creator>Ousji, Besma</creator><creator>Ennigrou, Dorra Jellouli</creator><general>Elsevier Inc</general><general>Elsevier Limited</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7QL</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7TN</scope><scope>7UA</scope><scope>8FD</scope><scope>C1K</scope><scope>F1W</scope><scope>FR3</scope><scope>H96</scope><scope>H97</scope><scope>KR7</scope><scope>L.G</scope><scope>M7N</scope><scope>P64</scope><scope>SOI</scope><scope>7TV</scope><scope>7U1</scope><scope>7U2</scope></search><sort><creationdate>20150710</creationdate><title>Reclamation of dairy wastewater using ultrafiltration process</title><author>Bennani, Cheïma Fersi ; Ousji, Besma ; Ennigrou, Dorra Jellouli</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c470t-636965df2a3c83036953b359fbf47f0586d3c88f1c7bb59ec7682867797da75b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Cooling</topic><topic>Dairy industry wastewaters</topic><topic>Dairy wastewater</topic><topic>Dissolved salts</topic><topic>Effluents</topic><topic>Optimization</topic><topic>Pasteurizing</topic><topic>Reclamation</topic><topic>Reduction</topic><topic>Retention</topic><topic>Retention rates</topic><topic>Turbidity</topic><topic>Ultrafiltration</topic><topic>Volume reduction factor</topic><topic>Wastewater discharges</topic><topic>Wastewater treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bennani, Cheïma Fersi</creatorcontrib><creatorcontrib>Ousji, Besma</creatorcontrib><creatorcontrib>Ennigrou, Dorra Jellouli</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Oceanic Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Engineering Research Database</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy & Non-Living Resources</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Civil Engineering Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><collection>Risk Abstracts</collection><collection>Safety Science and Risk</collection><jtitle>Desalination and water treatment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bennani, Cheïma Fersi</au><au>Ousji, Besma</au><au>Ennigrou, Dorra Jellouli</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reclamation of dairy wastewater using ultrafiltration process</atitle><jtitle>Desalination and water treatment</jtitle><date>2015-07-10</date><risdate>2015</risdate><volume>55</volume><issue>2</issue><spage>297</spage><epage>303</epage><pages>297-303</pages><issn>1944-3986</issn><issn>1944-3994</issn><eissn>1944-3986</eissn><abstract>Large amounts of water are daily used in dairy industries for different parts of their services such as chilling, cooling, steam production, pasteurizing, etc. This consumption generates a huge quantity of wastewaters which could be reused after performed treatment. In the present work, a real sample of dairy wastewater was treated using ultrafiltration (UF) and process efficiency and permeate quality were improved by operating under optimum conditions of transmembrane pressure (TMP) and volume reduction factor (VRF). More than 99% of retention rate were observed for turbidity and the BDO5, more than 80% for suspended matter, and 95% for proteins with an optimal TMP fixed at 2.5 bar. Moreover, a reduction of 40 and 55% was recorded for conductivity and the total dissolved salts, respectively. Rather important retention rates varying from 95 to 99% for the majority of the analyzed parameters were observed for a VRF range varying from 1.11 to 2.5. A recovery of 58% of the dairy effluent is possible after treatment by UF using the PES-5 membrane. The permeate quality obtained in optimal TMP and VRF allows the industry to reject its effluents into the river without risks of contamination (according to Tunisian standard for wastewater discharge NT106-02) and to reuse or recycle them during the process (according to Tunisian standard for reusing treated wastewater NT106-03).</abstract><cop>Abingdon</cop><pub>Elsevier Inc</pub><doi>10.1080/19443994.2014.913996</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1944-3986 |
ispartof | Desalination and water treatment, 2015-07, Vol.55 (2), p.297-303 |
issn | 1944-3986 1944-3994 1944-3986 |
language | eng |
recordid | cdi_proquest_miscellaneous_1709746227 |
source | Alma/SFX Local Collection |
subjects | Cooling Dairy industry wastewaters Dairy wastewater Dissolved salts Effluents Optimization Pasteurizing Reclamation Reduction Retention Retention rates Turbidity Ultrafiltration Volume reduction factor Wastewater discharges Wastewater treatment |
title | Reclamation of dairy wastewater using ultrafiltration process |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T14%3A18%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reclamation%20of%20dairy%20wastewater%20using%20ultrafiltration%20process&rft.jtitle=Desalination%20and%20water%20treatment&rft.au=Bennani,%20Che%C3%AFma%20Fersi&rft.date=2015-07-10&rft.volume=55&rft.issue=2&rft.spage=297&rft.epage=303&rft.pages=297-303&rft.issn=1944-3986&rft.eissn=1944-3986&rft_id=info:doi/10.1080/19443994.2014.913996&rft_dat=%3Cproquest_cross%3E1701474938%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1688646898&rft_id=info:pmid/&rft_els_id=S1944398624047921&rfr_iscdi=true |